LDD960-UU BEL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
LDD960-UU is a microprocessor controlled unit that can perform two functions: DC-UPS rated 960 W / 20 A usable in any system 12 – 48 VDC DC/DC converter (non -isolated) rated 960 W / 20 A usable in any combination of IN/OUT voltages 12 – 48 VDC For the UPS function it may use one 12 V battery, independently of the operating load voltage. For any supply voltages (12 – 48 VDC) it may use also multiple battery configuration (10 – 60 VDC). LDD960-UU monitors the voltage coming from a DC power supply and in case of power failure a backup storage source supplies the energy to the load. In normal condition the battery is kept charged by an integrated battery charger supporting various battery chemistries. As a DC/DC converter (no battery present), the input voltage is converted to any output voltage as per the set -up (programmable by front keys or communication interfaces). Digital power regulation, LCD interface Integrated battery charger for 12 – 48 V multi-chemistries batteries with a charging current up to 20 A Can operate with super capacitors modules Battery voltage independent of input and output voltage 20 A or 960 W rated load Multiple protections Remote ON/OFF or other remote control functions possible through INHIBIT input Measures voltages and currents on input, output and battery. Battery protection against reverse polarity connection and overcurrent Battery health monitoring system: measuring battery internal resistance, battery temperature, charge/discharge cycles and Coulomb counter User settable maximum backup time Auxiliary output with same voltage as battery (5A max.), protected against overcurrent/short-circuit 4 keys and 1 color graphic TFT LCD display Allows online device configuration Displays the LDD960-UU status and alarms Modbus over RS-485 and USB interfaces for control and monitoring Dry contacts for programmable status signals
2 LDD960-UU
tech.support@psbel.com Input DC Voltage Nominal Range 12 - 48 VDC 10 - 60 VDC Input DC Current 20 A Standby Power < 4 W Main Output Output Power 960 W Voltage Vin for use as UPS; according to set-up for use as DC/DC converter 12 - 48 VDC (Nominal) Maximum Current / Power 20 A / 960 W Load Regulation ± 1% Efficiency at Full Load Power Loss UPS mode with Vin present > 98% < 7 W Efficiency at Full Load Power Loss UPS mode during backup > 97% < 15 W Efficiency at Full Load Power Loss DC-DC mode > 97% < 15 W Auxiliary Output Voltage U battery – non-regulated 12 - 48 VDC (Nominal) Continuous current 5 A Overload limit 6 A Battery Voltage (or to be used as input for DC/DC conversion) Nominal Range 12 - 48 VDC 10 - 60 VDC Battery Chemistries Lead Acid; Nickel; Lithium; Supercap capacitors Maximum Battery Charge Current 20 A Maximum Battery Discharge Current 20 A Allowed Battery Capacity up to 400Ah Battery Protections Overcurrent Deep Discharge Reverse Polarity Battery Charge Efficiency Power Loss > 96% < 20 W Maximum Backup Time User programmable, up to battery deep discharge threshold Battery Health Monitoring Battery Internal Resistance Range U battery – non-regulated 1 mΩ – 300 mΩ Additional Monitoring Functions - Coulomb counter - Battery temperature through 10kΩ NTC sensor (optional WNTC-2MT) - Battery operating time since installation - Number of cycles
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00916_001 1.5 inch Color Graphic LCD Used to display the unit’s status and to access the configuration menus
4 Keys Used to program the unit and to access various menus
Red LED Constantly ON: generic failure on the system, details on the LCD Blinking: battery backup function active
2 Dry Contact Relays
(NO, 30 VDC / 1 A) RL1 / RL2 - Configurable RL COM - Common Pin Other Interfaces INH - (INHIBIT) Isolated remote ON/OFF input, active for 5 – 30 VDC T SENSE - optional, remote temperature sensor for battery charging (WNTC-2MT) Modbus over USB and RS-485 interfaces Operating Temperature 1 Overtemperature protection - 40 to + 80°C Storage Temperature - 40 to + 80°C Derating (See Figure 1 and 2) Humidity Non-condensing 5 - 95% RH Life Time Expectancy At 25°C ambient, full load 281 904 h (32.2 years) Overvoltage Category Pollution Degree EN50178 IEC60664-1 I Protection Class Class I Isolation Against Enclosure 0.75 kVDC Safety Standards & Approvals UL508 (reference) EN60950 (reference) EMC Standards Emission EN55022 (CISPR11) EN55011 (CISPR22) Class B Class B Immunity EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 Level 3 Level 3 Level 3 Level 1 Protection Degree EN60529 IP20 Vibration Sinusoidal IEC 60068-2-6 5-17.8 Hz: ±1.6 mm; 17.8-500 Hz: 2 g 2Hours / axis (X,Y,Z) Shock IEC 60068-2-27 30 g 6 ms, 20 g 11 ms; 3 bumps / direction, 18 bumps total
1 Start-up type tested: - 40°C, possible at nominal voltage with load derating
4 LDD960-UU
minimum 5 minutes of operation. 3 Power rating, losses, efficiency, ripple, thermal behaviour and start-up may change outside of the nominal rated input range. Contact factory for details. Figure 1. Current Derating Curve
6 LDD960-UU
tech.support@psbel.com MAIN CONNECTIONS IN: (connect to power supply in UPS mode) + = Positive DC - = Negative DC BATT/IN: (connect to battery in UPS mode or power supply in DC/DC mode) + = Positive DC - = Negative DC OUT: (connect to load) + = Positive DC - = Negative DC AUXILIARY CONNECTIONS RL1 / RL2: (programmable dry contact) RL1 = NO RL2 = NO RL COM = COM Modbus: (over RS-485, 2 wire interface) MBUS A = RX/TX MBUS B = RX/TX GND = Common INHIBIT: (5 – 30 VDC) ▪ INH+ = Positive DC ▪ INH- = Negative DC AUX: (12 – 48 VDC not regulated 5 A Max.) AUX + = Positive DC AUX - = Negative DC T SENSE: (remote temperature sensor for battery charging) Optional WNTC-2MT MINI USB TYPE 1 = VBUS (+5V) 2 = Data (D-) 3 = Data (D+) 4 = Not connected (ID) 5 = GND NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.