LDD240 BEL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
The LDD family of DC/DC converters is an optimal response to the applications where compactness and high reliability are requested. All are isolated and offer a wide range of input voltages. Simple but elegant look and ease of installation make them ideal for various industrial applications. High efficiency and compact size Wide Input voltage range Isolated topology Overload 150% Excellent reliability Industrial machine control Process control Energy management Remote control systems
2 LDD240 Series
tech.support@psbel.com LDD240-11024 110 VDC (90 - 148 VDC) 2.6 A – 3.6 A 24 VDC 10 A Technical parameters are typical, measured in laboratory environment at 25°C at 110 VDC and nominal values, after minimum 5 minutes of operation. Input DC Voltage Range Rated Operating
110 VDC
Input DC Current Vin = Min Vin = Max 3.6 A 2.6 A Input Overvoltage Protection Active shutdown > 150 VDC Inrush Peak Current < 150 A Internal Protection Fuse Not user replaceable Fuse AT 5 A Recommended External Protection Use DC rated devices MCB 6 A C curve Output Power 240 W Rated Voltage (Adjustable Voltage Range) 24 VDC (23 – 27.5 VDC) Continuous Current 10 A Overload Limit 15 A Short Circuit Peak Current 21 A Load Regulation ≤ 1.5% Ripple & Noise1 ≤ 50 mVpp Hold up Time ≥10 ms Protections Overload/short circuit: Hiccup mode Thermal protection Output overvoltage Output Over Voltage Protection ≥ 33 VDC Status Signals DC OK - green LED OVERLOAD - red LED DC OK - dry contact (NO, 24 VDC / 1 A) Parallel Connection Possible for power or redundancy (includes internal ORing circuit) Efficiency > 88 % Dissipated Power < 31 W 1 Ripple and Noise are measured with 20 MHz bandwidth, probe terminated with a 0.1 μF MKP parallel capacitor. NOTE: Power rating, losses, efficiency, ripple, thermal behaviour and start-up may change outside of the nominal rated input range. Contact factory for details.
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00763_AA Operating Temperature Overtemperature protection (Start-up type tested: - 40°C)2 - 40 to + 70°C Storage Temperature - 40 to + 80°C Derating - 3 W/°C over 50°C Humidity Non-condensing 5 - 95% RH Life time expectation At 25°C ambient 64000 h (7.3 years) Overvoltage Category Pollution Degree I (EN50178) 2 (IEC60664-1) Protection Class Class I Isolation Voltage Input to Output Input to Ground Output to Ground 2.1 kVDC 1.41 kVDC 0.75 kVDC Safety Standards & Approvals UL508 (reference) EN60950 (reference) EN50178 (reference) EMC Standards Emission EN55022 (CISPR11) EN55011 (CISPR22) Class A Class A Immunity EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-11 Level 3 Level 3 Level 2 Level 2 Level 2 Protection Degree EN60529 IP20 Vibration sinusoidal IEC 60068-2-6 5-17.8 Hz: ±1.6 mm; 17.8-500 Hz: 2 g 2Hours / axis (X,Y,Z) Shock IEC 60068-2-27 30 g 6 ms, 20 g 11 ms; 3 bumps / direction, 18 bumps total 2 Possible at nominal voltage with load deration. Weight 800 g Dimensions 69 x 115 x 110 mm Mounting Rail IEC 60715/H15/TH35-7.5(-15) Connection Terminals Screw type pluggable (24 - 12 AWG) 2.5 mm² Case Material Aluminum
4 LDD240 Series
Figure 1. Mechanical Drawing
1 DC input
2 DC output (Load)
3 Output voltage adjustment
4 Green LED: Output OK
5 Red LED: Overload
6 Diagnostic Output
equipment used in hazardous environments, or nuclear control systems. date manufactured. Specifications are subject to change without notice.