The LDD family of DC/DC converters is an optimal response to the applications where compactness and high reliability are requested. All are isolated and offer a wide range of input voltages. Simple but elegant look and easy installation make them ideal for various industrial applications. High efficiency and compact size Isolated topology Wide Input voltage range Overload 125% Up to 50°C operating temperature with no derating Industrial machine control Process control Energy management Remote control systems
2 LDD120 Series
tech.support@psbel.com LDD120-1212 12 VDC (10.5 - 18 VDC) 14 A - 8.0 A 12 VDC 7 A LDD120-1224 12 VDC (10.5 - 18 VDC) 15.5 A - 9.0 A 24 VDC 5 A LDD120-1248 12 VDC (10.5 - 18 VDC) 15.5 A - 9.0 A 48 VDC 2.5 A LDD120-2412 24 VDC (18 - 36 VDC) 7.5 A - 3.8 A 12 VDC 7 A LDD120-2424 24 VDC (18 - 36 VDC) 8.5 A - 4.3 A 24 VDC 5 A LDD120-4812 48 VDC (36 - 72 VDC) 4.5 A - 2.5 A 12 VDC 8 A LDD120-4824 48 VDC (36 - 72 VDC) 4.3 A - 2.2 A 24 VDC 5 A Technical parameters are typical, measured in laboratory environment at 25°C and nom. values, after min. 5 minutes of operation. PARAMETER DESCRIPTION / CONDITION SPECIFICATION Input DC Voltage Range LDD120-1212 / LDD120-1224 / LDD120-1248 LDD120-2412 / LDD120-2424 LDD120-4812 / LDD120-4824 12 VDC (10.5 - 18 VDC)
24 VDC (18 - 36 VDC)
48 VDC (36 - 72 VDC)
LDD120-1212 Vin = Min Vin = Max 14 A 8.0 A LDD120-1224 / LDD120-1248 Vin = Min Vin = Max 15.5 A 9.0 A LDD120-2412 Vin = Min Vin = Max 7.5 A 3.8 A LDD120-2424 Vin = Min Vin = Max 8.5 A 4.3 A LDD120-4812 Vin = Min Vin = Max 4.5 A 2.5 A LDD120-4824 Vin = Min Vin = Max 4.3 A 2.2 A Input Overvoltage Protection (active) LDD120-1212 / LDD120-1224 / LDD120-1248 LDD120-2412 / LDD120-2424 LDD120-4812 / LDD120-4824
19 VDC
38 VDC
76 VDC
(not user replaceable) LDD120-1212 / LDD120-1224 / LDD120-1248 LDD120-2412 / LDD120-2424 LDD120-4812 LDD120-4824 Fuse 20 AT Fuse 10 AT Fuse 8 AT Fuse 5 AT Recommended External Protection (use DC rated devices) LDD120-1212 / LDD120-1224 / LDD120-1248 LDD120-2412 / LDD120-2424 LDD120-4812 / LDD120-4824 > MCB 25 A C curve > MCB 13 A C curve > MCB 6 A C curve
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2016 Bel Power Solutions & Protection BCD.00762_AA Output Power 120 W Rated Voltage (Adjustable Voltage Range) LDD120-1212 / LDD120-2412 / LDD120-4812 LDD120-1224 / LDD120-2424 / LDD120-4824 LDD120-1248
12 VDC (12 - 15 VDC)
24 VDC (23 – 27.5 VDC)
48 VDC (45 – 55 VDC)
2.5 A 7 A 5 A 8 A 5 A Overload Limit LDD120-1212 LDD120-1224 LDD120-1248 LDD120-2412 LDD120-2424 LDD120-4812 LDD120-4824 9.0 A 7.0 A 3.3 A 9.0 A 6.5 A 12 A 6.5 A Short Circuit Peak Current LDD120-1212 / LDD120-1224 LDD120-1248 LDD120-2412 LDD120-2424 LDD120-4812 LDD120-4824 11.5 A 5.8 A 14 A 10 A 20 A 12 A Load Regulation LDD120-1212 / LDD120-1224 / LDD120-1248 / LDD120-2412 / LDD120-2424 / LDD120-4812 LDD120-4824 ≤ 0.5% ≤ 1.5% Ripple & Noise1 LDD120-1212 / LDD120-1224 / LDD120-1248 LDD120-2412 LDD120-2424 / LDD120-4812 LDD120-4824 ≤ 20 mVpp ≤ 50 mVpp ≤ 20 mVpp ≤ 30 mVpp Hold up Time LDD120-1212 ≥ 4 ms LDD120-1224 / LDD120-1248 / LDD120-2412 / LDD120-2424 ≥ 3 ms LDD120-4812 LDD120-4824 ≥ 5 ms ≥ 6 ms Output Over Voltage Protection LDD120-1212 / LDD120-2412 / LDD120-4812 LDD120-1224 / LDD120-2424 / LDD120-4824 LDD120-1248 ≥ 18 VDC ≥ 33 VDC ≥ 68 VDC Parallel Connection Possible for redundancy (with external ORing module) Protections Overload/short circuit: Hiccup mode Thermal protection Output overvoltage Status Signals DC OK - Green LED (all models) OVERLOAD - Status Signals red LED (LDD120-4812 only) DC OK dry contact (NO, 24 VDC / 1 A) (LDD120-4812 only) Efficiency LDD120-1212 LDD120-1224 LDD120-1248 LDD120-2412 / LDD120-2424 LDD120-4812 / LDD120-4824 > 81% > 82% > 83% > 86% > 89% Dissipated Power LDD120-1212 LDD120-1224 LDD120-1248 LDD120-2412 LDD120-2424 LDD120-4812 LDD120-4824 < 20 W < 25 W < 24 W < 14 W < 20 W < 15 W < 16 W 1 Ripple and Noise are measured with 20 MHz bandwidth, probe terminated with a 0.1μF MKP parallel capacitor. NOTE: Power rating, losses, efficiency, ripple, thermal behaviour and start-up may change outside of the nominal rated input range. Contact factory for details.
4 LDD120 Series
tech.support@psbel.com Operating Temperature Overtemperature protection (Start-up type tested: - 40°C)* - 40 to + 70°C Derating - 3 W/°C over 50°C Storage Temperature - 40 to + 80°C Humidity Non-condensing 5 - 95% RH non condensing Life Time Expectation AT 25°C ambient 64000 h (7.3 years) Overvoltage Category Pollution Degree I (EN50178) 2 (IEC60664-1) Protection Class Class I Isolation Voltage Input to Output Input to Ground Output to Ground 2.1 kVDC 1.41 kVDC 0.75 kVDC Safety Standards & Approvals UL508 (reference) EN60950 (reference) EN50178 (reference) EMC Standards Emission EN55022 EN55011 Class A Class A Immunity EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-11 Level 3 Level 3 Level 2 Level 2 Level 2 Protection Degree EN60529 IP20 Vibration sinusoidal IEC 60068-2-6 5-17.8 Hz: ±1.6 mm; 17.8-500 Hz: 2 g 2Hours / axis (X,Y,Z) Shock IEC 60068-2-27 30 g 6 ms, 20 g 11 ms; 3 bumps / direction, 18 bumps total * Possible at nominal voltage with load derating. Weight 0.5 kg Dimensions 54 x 115 x 110 mm Mounting Rail IEC 60715/H15/TH35-7.5(-15) Connection Terminals Screw type pluggable (24 - 12 AWG) 2.5 mm² Case Material Aluminum
Figure 1. Mechanical Drawing
1 DC input
2 DC output (Load)
3 Output voltage adjustment
4 Green LED: Output OK
equipment used in hazardous environments, or nuclear control systems. date manufactured. Specifications are subject to change without notice.