Connecting links with manual motor starters

Description

motor starters. The BEA..-4 insulated 3-pole connecting links ensure the electrical and mechanical connection between the con- tactor and the associated manual motor starter. Ordering Details For contactors Type Order code Pack(ing) Weight pieces kg (1 pce) AF09 ... AF16 with MS116 and MS132 BEA16-4 1SBN 081 306 T1000 10 0.025 Connection sets for reversing contactors BER16-4 and BER38-4 connection sets between the main poles of two 3-pole contactors mounted side by side. The connection sets are made up of 1 upstream and 1 downstream connections: insulated, solid copper bars. Ordering Details For contactors Type Order code Pack(ing) Weight pieces kg (1 pce) AF09 ... AF16 BER16-4 1SBN 081 311 R1000 1 0.045 AF26 ... AF38 BER38-4 1SBN 082 311 R1000 1 0.100 Connection sets for Star-Delta starting BEY16-4 and BEY38-4 connection sets between the main poles of the Line, Delta and Star contactors of a Star- Delta starter. The connection sets are made up of: — Line contactor / Delta contactor: upstream phase-to-phase connection — Delta contactor / Star contactor: downstream connection in parallel — Star contactor: Star point upstream. Ordering Details For Line, Delta and Star contactors Interlock unit between Delta & Star contactors Type Order code Pack (ing) Weight pieces kg (1 pce) AF09 ... AF16 With or without VM4 or VEM4 BEY16-4 1SBN 081 313 R2000 1 0.050 AF26 ... AF38 BEY38-4 1SBN 082 713 R2000 1 0.110 Connexion Accessories for Starting Solutions Accessories for AF09 ... AF38 3-pole Contactors Catalogue Page 14 | ABB

Accessories for AF09 ... AF38 3-pole Contactors VM4 VEM4 A2 A2 01NC01NC VEM4 KM1 KM2 BB4 Mechanical interlock unit VM4 mechanical interlock unit for the interlocking of two AF contactors. When mounted between two contactors without additional width, the VM4 mechanical interlock unit prevents one of the contactors from closing as long as the other contactor is closed. The mechanical interlock unit includes 2 fixing clips (BB4). Ordering Details For contactors Type Order code Pack(ing) Weight pieces kg (1 pce) AF09 ... AF38 VM4 1SBN 030 105 T1000 10 0.005 Mechanical and electrical interlock set VEM4 mechanical and electrical interlock set for the interlocking of two AF contactors. VEM4 set includes a mechanical interlock unit VM4 with 2 fixing clips (BB4) and a VE4 electrical interlock block with A2-A2 connection. Fixing the electrical interlock block to the contactor front face connects the 2 built-in N.C. interlocking contacts with the two coils. VE4 block must be used with A2-A2 connection to respect the electrical connection diagram. Ordering Details For contactors Auxiliary contacts Type Order code Pack(ing) pieces Weight kg (1 pce) AF09 .. AF16 1 1 VEM4 1SBN 030 111 R1000 1 0.035 AF26 .. AF38 Fixing clips Ordering Details For contactors Type Order code Pack(ing) Weight pieces kg (1 pce) AF09 ... AF38 BB4 1SBN 110 120 W1000 50 0.002 Catalogue Page 1SBC 101 146 S0201 ABB | 15

Accessories for AF09 ... AF38 3-pole Contactors Interlock types VM4 Mechanical durability Number of operating cycles 5 millions operating cycles Max. switching frequency 1800 cycles/h Interlock types VEM4 Contact Utilization Characteristics according to IEC Standards IEC 60947-5-1 and EN 60947-5-1 Rated insulation voltage Ui acc. to IEC 60947-5-1 690 V Rated impulse withstand voltage Uimp 6 kV Rated control circuit voltage Uc AC 50/60 Hz control voltage 24 ... 500 V AC DC control voltage 20 ... 500 V DC Conventional thermal current Ith - θ ≤ 40 °C 16 A Mechanical and electrical durability Number of operating cycles 5 millions operating cycles Max. mechanical switching frequency 1800 cycles/h Max. electrical switching frequency 1200 cycles/h Contact Utilization Characteristics according to UL / CSA Standards UL 508, CSA C22.2 N°14 Max. rated voltage 500 V AC, 500 V DC Connecting Characteristics Screw terminals All terminals M3.5 Rigid Solid 1 x 1 ... 2.5 mm² 2 x 1 ... 2.5 mm² L Bars or lugs L < 8 mm Capacity according to UL/CSA 1 or 2 x AWG 18 ... 14 Stripping length 10 mm Degree of protection acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 IP20 Screwdriver type Flat Ø5.5 / Pozidriv 2 Tightening torque 1.2 Nm / 11 lb.in Technical Data Catalogue Page 1SBC 101 146 S0201 16 | ABB

1SBC 101 147 S0201Other Accessories Accessories for AF09 ... AF38 3-pole Contactors LDC4 BX4 BX4-CA BA4 Additional coil terminal block Additional coil terminal block for a bottom access to the coil terminals of contactors or contactor relays. Ordering Details For contactors Type Order code Pack(ing) Weight pieces kg (1 pce) AF09 ... AF38 LDC4 1SBN 070 156 T1000 10 0.010 Protective covers Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against ac- cidental contact. Ordering Details For contactors Type Order code Pack(ing) Weight pieces kg (1 pce) All 1-stack contactors BX4 1SBN 110 108 T1000 10 0.006 For 4-pole CA4 and 2-pole CAT4 auxiliary contact blocks BX4-CA 1SBN 110 109 W1000 50 0.001Function markers Box of 16 blank cards (16 markers by card) printable on HTP500 thermal transfer printer and AMS 500 marking table to identify your contactors, overload relays or manual motor starters. Marker dimensions: 7 x 20 mm (.276" x .787") Ordering Details For contactors Type Order code Pack(ing) Weight pieces kg (1 pce) Marker card BA4 1SNA 235 156 R2700 16 0.011 AMS 500 support plate for 8 BA4 SPRC 1 1SNA 360 010 R1500 1 0.220 HTP500 support plate HTP500-BA4 1SNA 235 712 R2400 1 0.290 Catalogue Page ABB | 17