LD310_LD1000_LDRA6 VERIS | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 2
Technical content
Alarm Notification: Audible Alarm LD1000 LDRA6 85 dBA@2 ft. (0.6 m) 85dBA@2 ft. (0.6 m) re-sound disabled, 8, 16, or 24 hrs. Push Buttons: LD1000, LDRA6 1 for reset, quiet, and test OPERATING ENVIRONMENT Temperature 0 to 50 °C (32 to 122 °F) Humidity 5% to 95% RH non-condensing Altitude 15,000 ft. (4,572 m) max Storage Environment -20 to 70 °C (-4 to 158 °F) Weight: LD310 LD1000 LDRA6 3 oz. (85 g) 27 oz. (766 g) 4 lbs. (2 kg) AGENCY APPROVALS Agency Approvals: LD310 LD1000 LDRA6 CE, RoHS compliant CE, ETL listed; conforms to UL 61010-1, RoHS compliant CE ETL Listed; conforms to UL 61010-1, EN 61010-1, CAN/CSA C22.2 No. 1010.1, RoHS compliant WARRANTY Limited Warranty 2 years Input Power: LD310 LD1000 LDRA6
5 Vdc ±10%
24 Vac/dc (±10%)@300 mA max. (AC: 50/60 Hz) 24 Vac/dc (±10%)@600 mA max. (AC: 50/60 Hz) Relay Output: LD310 LD1000 LDRA
2 Form C relays (leak and fault); 1 A@24 Vdc,
0.5 A resistive@120 Vac
1 Form C summary alarm relay, 1 Form C relay
for each zone/alarm; 1 A@24 Vdc, 0.5 A Resistive@120 Vac INPUTS Water Leak Detection Cable Requires 15 ft. (4.5 m) leader cable kit (LC-Kit) per zone. Maximum Cable Length: LD310 LD1000, LDRA6 300 ft. (91 m) 1000 ft. (305 m) Detection Response Time: LD310 LD1000 LDRA6 < 20 sec (10 sec typical) Configurable for 10 sec or 2 min, ± 10% 20 to 3600 sec, software adjustable in 10 sec increments, ± 2% COMMUNICATION PORTS (LDRA6 ONLY) RS-232 & RS-485 1200, 2400, 9600, or 19200 selectable; no parity; 8 data bits, 1 stop bit Terminal Emulation (RS-232) VT100 Compatible (configuration) Modbus (RS-485) (LDRA6 only) Slave; RTU Mode; Supports function codes 03, 04, 06 and 16 LD310, LD1000, and LDRA6 control panels continuously monitor up to 1,000 ft. (300 ft. for the LD310) of SC detection cable per zone. If the cable detects fluid at any point along its length, the detection panel illuminates the corresponding zone LED, clearly indicating which zone is affected. An alarm (visual for LD310, audible for all others) signals the presence of a leak. Additionally, if the cable loses continuity, the panel will activate a cable fault LED. The detection sensitivity can be set independently for each zone. A summary alarm relay output is standard. The LDRA6 can interface with a computer via an RS-232 port, through which 117 days of cable current level readings and the last 100 alarms can be accessed for analysis. The LDRA6 also offers a Modbus slave port allowing other devices to communicate with it. SPECIFICATIONS Application flexibility Monitor up to 1,000 ft. (300 m) of water leak detection cable per zone with the LD1000 and LDRA6 or 300 ft. per zone with the LD310 Output versatility Alarm and trend logs of the last 100 alarms and 117 days of cable current levels, plus RS-232 and Modbus RS-485 ports (LDRA6 only) LED indicators Two LED indicators per zone, for easy troubleshooting…leak and cable fault (LD1000 and LDRA6) Fast response Summary alarm relay output... fast response Sensitivity settings Sensitivity settings for each zone reduce false alarms…maximum detection accuracy
APPLICATIONS
- Monitoring data centers, computer room under-floor areas, mechanical rooms, and electrical control centers
- Protecting records storage
- Monitoring plumbing
- Monitoring chilled beams
- Monitoring chemical/fuel storage INTERTEK C US LISTED CM LISTED 3037024 LDRA6 LD1000 LD310 LD310, LD1000, & LDRA6 Zone Leak Detection Controllers Leak Detection | Zone Leak Detection Panels HQ0001795.H 0321
(EOL) Leader cable kit (LC-Kit) Spot detector (SD-Z) LD1000 LD310 2.5” (63.5 mm) 4.4” (112 mm) LD310 Power Fault Leak Quiet/Reset/Test 5.5” (140 mm) 4.2” (105 mm) Alarm/Zone 1 Alarm/Zone 2 Alarm/Zone 3 Power Alarm/Zone 4 Alarm/Zone 5 Alarm/Zone 6 Test/Reset/Silence 8.0” (203 mm) 10.5” (267 mm) MODEL MANUF. PART # DESCRIPTION U006-0080* LD310* Leak Panel, 1 zone, LED, 2 relay outputs U006-0001 LD1000 Leak Panel/Remote Annunciator, 1 zone, supervised, relay output U006-0036 LDRA6 Leak Panel, up to 6 zones, supervised, relay output, Modbus RTU U006-0035 LC-KIT*** Leader cable kit for SC cables (connects from leak panel to SC or NSC cable) U006-0037 WA-DC-05 Power Supply for LD300 U006-0084 PS-WA-DC-24 Power Supply for LD1000 and LDRA6 MODEL LED INDICATION DEVICE STATUS LD310 Solid green (on or off) Normal operation LD310 Flashing green (0.5 sec on/2.5 sec off) Cable fault LD310 Flashing green (0.5 sec on/0.5 sec off) Leak detected LD1000 Solid green (on or off) Normal operation LD1000 1 amber Cable fault LD1000 1 red Leak detected LDRA6 Solid green (on or off) Normal operation LDRA6 1 green Power on LDRA6 1 red Leak detected LDRA6 1 yellow Cable fault LD310 Wiring Diagram LD310 Dimensional Drawing LD1000 Dimensional Drawing LD310 OR LD1000 BASIC INSTALLATION WITH SC SENSING CABLE AND SD-Z SPOT DETECTOR Wiring Diagram LDRA6 Dimensional Drawing
ORDERING INFORMATION
- Power supply not included; requires U006-0037 power supply. Power supply not included; requires U006-0084 power supply. * Included with LD310 and LD1000. Be sure the leader cable is wired into the correct pinouts.5VDC Power Input Cable Fault Relay Output Leak Relay Output Top 2 Pins - Supervised Bottom 2 Pins - Non-supervised LED Audible Alarm Silence/Test/ Reset Button Circuit Board Clip L Brackets Plastic Peg JP3 - Audible Alarm Top 2 Pins - Disabled Bottom 2 Pins - Enabled JP1 - Leak Sensitivity Top 2 Pins - Most sensitive No Jumper - Medium sensitivity Bottom 2 Pins - Least sensitive Plastic Peg Leader Cable / Leak Detection Input ACCESSORIES P. 153 Leak Detection | LD310, LD1000, & LDRA6Leak Detection | Zone Leak Detection Panels HQ0001795.H 0321