LCT43-E ASTEC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662 Special Features
47 Watts
rev 8.11.04 VDE 0805/EN60950 (IEC950) 21310-3336-0003 UL UL1950 E186249 CSA CSA 22.2-234 -950-95-M90 CB Certificate and report 6593 CE Mark (LVD)
- Totally enclosed
- Universal input
- Quick Installation
- Built-in EMI filter
- Low output ripple
- Overvoltage protection
- Overload protection Operating temperature: 0° to 50°C ambient; derate each output at 2.5% per degree from 50° to 70°C Electromagnetic susceptibility: designed to meet Humidity: Operating; non-condensing 5% to 90% Vibration: .41 G from 3 to 500 Hz Spectral break points of .0065 G2/Hz at 10 Hz and
200 Hz and 5 db/octave roll off at each end, 2
Storage temperature: -40° to 85°C Temperature coefficient: ±.04% per °C MTBF demonstrated: >300,000 hrs @ full load and 25°C ambient conditions Input Input range 85-264 VAC 120-300 VDC Frequency 47-63 Hz Inrush current <20 A peak @ 115 VAC; <40 A peak @ 230 VAC, cold start @ 25°C Input current 1 A max. (RMS) @ 115 VAC Efficiency 70% typical at full load EMI filter FCC Class B conducted and radiated CISPR 22 Class B conducted and radiated EN55022 Class B conducted and radiated Bellcore GR-1089-core Class B conducted Safety ground leakage current <3.5 mA @ 50/60 Hz, 264 VAC input Output Maximum power 47 W with 12 CFM forced air Cross regulation ±2% on output 1; ±5% on outputs 2, 3 Hold-up time 10 ms @ 47 W load, 100 VAC input Overload protection Short circuit protection on all outputs. Case overload protected @ 110- 135% above peak rating Overvoltage protection 5.50-6.75 VDC on main output Environmental Safety Total Power: 47 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Triple
Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44(1384) 843-355 AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 www.astecpower.com
Ordering Information
Model Output Minimum Maximum Load with Maximum Load with Peak Regulation2 Ripple Number Voltage Load Convection Cooling 12 CFM Forced Air Load1 P/P (PARD)3 LCT43-E +5 V 1.0 A 4 A 7 A 8 A +4 / -2% 50 mV +12 V 0.1 A 1 A 1.2 A 1.5 A ±5% 120 mV -12 V 0 A 0.5 A 0.5 A 0.6 A ±5% 120 mV 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 4. Minimum Loads are required. Connector LCT43-E SK1-1 AC Line SK1-2 Ground SK1-3 AC Neutral SK2-1 -12 V SK2-2 Com SK2-3 +5 V SK2-4 +5 V SK2-5 Com SK2-6 +12 V Mating Connectors AC Input: IEC 320 DC Outputs: Molex 15-48-0406 (USA) Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±.02”. 3. Specifications are for convection rating at factory settings at 115 VAC input, 25°C unless otherwise stated. 4. Warranty: 1 year 5. Weight: 1.25 lb. / 0.57 kg Pin Assignments LCT43-E Series