Revision March 1,2022 Axial Lead Transient Voltage Suppressors (TVS) www.unsemi.com.tw
6.5 To 90V 1500W Low Capacitance
www.unsemi.com.tw For technical questions, contact: tech@unsemi.com.tw Specifications are subject to change without notice. Please refer to www.unsemi.com.tw for current information.1/5 Glass passivated junction . 1500W peak pulse power capability with a 10/1000 μ s waveform, repetitive rate (duty cycle):0.01 % . Low leakage . Excellent clamping capability . Very fast response time . Plastic package has Underwriters Laboratory Flammability 94V-0 . Halogen free and RoHS compliant . TVS devices are ideal for the protection of I/O interfaces, VCC bus and other vulnerable circuits used in Telecom, Computer, Industrial and Consumer electronic applications. Uni-directional Bi-directional Maximum Ratings (TA=25℃ unless otherwise noted) Notes: 1. Non-repetitive current pulse , per Fig. 3 and derated above TA= 25°C per Fig. 2 Parameter Symbol Value Unit Peak Pulse Power Dissipation with a 10/1000µs waveformč1Ď Peak Pulse Current with a 10/1000µs waveform. (Fig.2)č1Ď Power Dissipation on Infinite Heat Sink at TL=75°C (Fig.2) Junction and Storage Temperature Range. Operating Temperature Range PPPM IPP PM(AV) TJ, TSTG TOP 1500 See Next Table 6.5 - 55 to +150 - 40 to +125 W A W
Axial Lead Transient Voltage Suppressors (TVS) Revision March 1,2022 www.unsemi.com.tw For technical questions, contact: tech@unsemi.com.tw ROHS Specifications are subject to change without notice. Please refer to www.unsemi.com.tw for current information.2/5 LCE Series VRWM (V) Breakdown Voltage VBR (V) @IT Maximum Clamping Voltage VC @IPP (V) Maximum Peak Pulse Current IPP (A) Maximum Reverse Leakage IR @VRWM (μA) Test Current IT (mA) MIN MAX Maximum Junction Capacitance @0V (pF) Working Inverse Blocking Voltage VWIB (V) Inverse Blocking Leakage Current IIB @VWIB(mA) Peak Inverse Voltage VPIB (V) 8.82 7.98 9.51 8.60 10.20 9.21 10.90 9.83 11.50 10.40 12.20 11.10 13.60 12.30 14.90 13.50 16.30 14.70 17.60 15.90 19.10 17.20 20.40 18.50 21.80 19.70 23.10 20.90 24.40 22.10 27.10 24.50 29.80 26.90 32.60 29.50 35.30 31.90 38.00 34.40 36.80 40.60 44.20 49.10 52.80 55.30 58.90 62.70 66.30 71.20 73.70 78.60 86.00 92.10 104.00 111.00 7.22 7.22 7.78 7.78 8.33 8.33 8.89 8.89 9.44 9.44 10.00 10.00 11.10 11.10 12.20 12.20 13.30 13.30 14.40 14.40 15.60 15.60 16.70 16.70 17.80 17.80 18.90 18.90 20.00 20.00 22.20 22.20 24.40 24.40 26.70 26.70 28.90 28.90 31.10 31.10 33.30 36.70 40.00 44.40 47.80 50.00 53.30 56.70 60.00 64.40 56.70 71.10 77.80 83.30 94.40 100.00 LCE6.5 LCE6.5A LCE7.0 LCE7.0A LCE7.5 LCE7.5A LCE8.0 LCE8.0A LCE8.5 LCE8.5A LCE9.0 LCE9.0A LCE10 LCE10A LCE11 LCE11A LCE12 LCE12A LCE13 LCE13A LCE14 LCE14A LCE15 LCE15A LCE16 LCE16A LCE17 LCE17A LCE18 LCE18A LCE20 LCE20A LCE22 LCE22A LCE24 LCE24A LCE26 LCE26A LCE28 LCE28A LCE30A LCE33A LCE36A LCE40A LCE43A LCE45A LCE48A LCE51A LCE54A LCE58A LCE60A LCE64A LCE70A LCE75A LCE85A LCE90A 6.5 6.5 7.0 7.0 7.5 7.5 8.0 8.0 8.5 8.5 9.0 9.0 10.0 10.0 11.0 11.0 12.0 12.0 13.0 13.0 14.0 14.0 15.0 15.0 16.0 16.0 17.0 17.0 18.0 18.0 20.0 20.0 22.0 22.0 24.0 24.0 26.0 26.0 28.0 28.0 30.0 33.0 36.0 40.0 43.0 45.0 48.0 51.0 54.0 58.0 60.0 64.0 70.0 75.0 85.0 90.0 Electrical Characteristics (TA=25℃ unless otherwise noted) 100 100 100 100 100 100 100 100 100 12.3 11.2 13.3 12.0 14.3 12.9 15.0 13.6 15.9 14.4 16.9 15.4 18.8 17.0 20.1 18.2 22.0 19.9 23.8 21.5 25.8 23.2 26.9 24.4 28.8 26.0 30.5 27.6 32.2 29.2 35.8 32.4 39.4 35.5 43.0 38.9 46.6 42.1 50.1 45.5 48.4 53.3 58.1 64.5 69.4 72.7 77.4 82.4 87.1 93.6 96.8 103.0 113.0 121.0 129.0 146.0 1000 1000 500 500 250 250 100 100 100 100 100 100 125 125 125 125 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 100 100 100 100 100 100 100 100 100 100 100 100 125 125 125 125 150 150 150 150 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
Axial Lead Transient Voltage Suppressors (TVS) Revision March 1,2022 www.unsemi.com.tw For technical questions, contact: tech@unsemi.com.tw ROHS Specifications are subject to change without notice. Please refer to www.unsemi.com.tw for current information. LCE Series Ratings and Characteristic Curves (TA=25°C unless otherwise noted) Figure 3 - Pulse Waveform Figure 1 - Peak Pulse Power Rating Curve Figure 4 - AC Line Protection Application PPPM - Peak Pulse Power (kW)0.1 100 0.1 1 10 100 1000 10000 t - Time (ms) 10/1000µsec. Waveform as defined by R.E.A Half Value IPPM (IPPM/2) Peak Value IPPM TR=10µsec TJ=25°C Pulse Width(td) is defined as the point where the peak current decays to 50% of IPPM 0 1.0 2.0 3.0 4.0 100 150 IPPM - Peak Pulse Current, % IR SM Figure 2 - Pulse Derating Curve TL - Lead temperature(°C) 0 25 50 75 100 125 150 175 100 Percentage of Rated Power (IPP) 200 Power Dissipation Peak Power (Single Pulse) TJ=Initial Temperature Low Capacitance TVS Application Note: Device must be used with two units in parallel, opposite in polarity as shown in circuit for AC signal line protection. TD - Pulse Width (μs)
Axial Lead Transient Voltage Suppressors (TVS) Revision March 1,2022 www.unsemi.com.tw For technical questions, contact: tech@unsemi.com.tw ROHS Specifications are subject to change without notice. Please refer to www.unsemi.com.tw for current information.4/5 LCE Series A B C D 1.000 0.285 0.038 0.189 0.375 0.042 0.209 25.40 7.24 0.97 4.79 9.53 1.07 5.30 DO-201 Cathode Band Physical Specifications Environmental Specifications Soldering Parameters Ramp up TSMAX TSMIN Ramp down TimeReflow Profile ReTime to peak temperature Temperature TP TL Critical Zone TL to TP TL T 25℃ to Peak Ts Preheat TP Lead–free assembly 150°C 200°C 60 -180 Seconds 3°C/second max 3°C/second max 217°C 60 -150 Seconds 260 +0/-5°C 20 - 40 Seconds 6°C/second max 8 minutes Max 280°C Reflow Condition Pre Heat -Temperature Min (Ts(min)) -Temperature Max (Ts(max)) - Time (min to max) (TS) Average ramp up rate ( Liquidus Temp TL) to peak TS(max) to TL - Ramp-up Rate Reflow - Temperature (TL) (Liquidus) - Time (min to max) (TS) Peak Temperature (TP) Do not exceed Time 25°C to peak Temperature (TP) Time within 5°C of actual peak Temperature (TP) Ramp-down Rate Weight Case Polarlty Terminal Color band denotes cathode except Bipolar 0.032 ounce, 0.9 gram JEDEC DO-201 Molded Plasticover glass passivated junction Matte Tin-plated leads, Solderable per JESD22-B102D JESD22-A104 JESD22-A102 JESD22-A103 JESD22-A108 JESD22-A106 Temperature Cycle Pressure Cooker High Temp. Storage HTRB Thermal Shock
Axial Lead Transient Voltage Suppressors (TVS) Revision March 1,2022 www.unsemi.com.tw For technical questions, contact: tech@unsemi.com.tw ROHS Specifications are subject to change without notice. Please refer to www.unsemi.com.tw for current information.5/5 LCE Series
Ordering Information
Part Number Component Package Quantity Packaging Option LCEXXX DO-201 1000 pcs Box 5% VBR VOLTAGE TOLERANCE VR VOLTAGE SERIES
Revision March 1,2022 www.unsemi.com.tw For technical questions, contact: tech@unsemi.com.tw ROHS Specifications are subject to change without notice. Please refer to www.unsemi.com.tw for current information. Disclaimer ROHS UNSEMI RESERVES THE RIGHT TO MAKE CHANGE ON OUR PRODUTS , PRODUCTS SPECIFICATION AND DATA WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. UN SEMICONDUCTOR LIMITED its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “UNSEMI”)does not give any representations or warranties for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. In no event shall UNSEMI be liable for any indirect, incidental, punitive, special or consequential damages (including any and all implied warranties, warranties of fitness for particular purpose, non-infringement and merchantability.) whether or not such damages are based on tort (including negligence), warranty, breach of contract or any other legal theory. Statements regarding the suitability of products for certain types of applications are based on UNSEMI knowledge of typical requirements that are often placed on UNSEMI products in generic applications. Such statements are not binding, statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify UNSEMI's terms and conditions of purchase, including but not limited to the warranty expressed therein. Unless otherwise agreed in writing, UNSEMI product is not designed, authorized or warranted to be suitable for use in medical life-saving, or life-sustaining application , nor in applications where failure or malfunction of a UNSEMI product can reasonably be expected to result in personal injury, death or severe property or environmental damage. UNSEMI and its suppliers accept no liability for inclusion or use of UNSEMI products in such equipment or applications and therefore such inclusion and/or use is at the customer's own risk. All referenced brands, product names, service names and trademarks are the property of their respective owners.