WLF12 Flexible LED Strip Light Instruction Manual Original Instructions p/n: 239483 Rev. A March 08, 2024 © Banner Engineering Corp. All rights reserved.
March 08, 2024 WLF12 Flexible LED Strip Light Instruction Manual © Banner Engineering Corp. All rights reserved. Chapter Contents Banner’s WLF12 Flexible LED Strip Light has been engineered to integrate easily into a broad range of industrial applications and environments. Its rugged yet flexible housing can be cut to length, allowing users to customize the light to their ideal shape. The light installs easily with integral high-strength adhesive tape, for creative use on a work station, assembly station, machine, or in a cabinet. Provides bright illumination in workspaces, cabinets, and machines with 285 lumens per 300 mm Durable, silicone-encapsulated housing provides long-lasting, worry-free performance
24 V DC EMI hardened circuitry ensures flicker-free operation and uniform light output
Plug-and-play standard M12 connections simplify installation by eliminating soldering Peel-and-stick installation using high-strength adhesive backing ensures quick and secure mounting Six housing lengths (from 300 mm to 4000 mm) can be cut in 50 mm increments to fit exact application specifications Rated IP67 and IP69K per DIN 40050-9 to withstand harsh conditions; is dust-resistant and tolerant of high temperatures Optional brackets are available for an even more secure installation and positioning Both straight and curved installation possible IMPORTANT: Read the following instructions before operating the light. Please download the complete WLF12 Flexible LED Strip Light technical documentation, available in multiple languages, from www.bannerengineering.com for details on the proper use, applications, Warnings, and installation instructions of this device. For PWM dimming, use with the LC15T-127AP2RBGQP or LC25T-AP2RGBQ dimmer modules. For more information, refer to the LC15T In-Line Touch Switch datasheet, p/n 217460, or to the LC25T In-Line Touch Switch datasheet, p/n 231078. For single color models only. FeaturesChapter 1
March 08, 2024 WLF12 Flexible LED Strip Light Instruction Manual (1) Models with a quick-disconnect connector require a mating cordset. © Banner Engineering Corp. All rights reserved. Chapter Contents Model Key Family Cascade Color Lighted Length (mm) Construction Voltage Connector(1) WLF12 X W 300 S 24 QP WLF12 X = Non- cascadeable W = Daylight White (5000K) 300 = 300 mm S = Sealed (IP66, IP67, IP69K per DIN 40050-9) 24 = 24 V DC QP = 150 mm (6 in) PVC- jacketed cable with a 4-pin M12 male quick-disconnect connector 600 = 600 mm 1200 = 1200 mm 2000 = 2000 mm 3000 = 3000 mm 4000 = 4000 mm ModelsChapter 2
March 08, 2024 WLF12 Flexible LED Strip Light Instruction Manual © Banner Engineering Corp. All rights reserved. Chapter Contents 4-pin Male M12 Pinout Pinout Key and Wiring WiringChapter 3 Brown - 24 V DC1. White - Not used2. Blue - DC Common3. Black - Not used4.
March 08, 2024 WLF12 Flexible LED Strip Light Instruction Manual © Banner Engineering Corp. All rights reserved. Chapter Contents Cutting InstructionsChapter 4 Prepare the flexible LED strip light and remove power.1. Cut along one of the cutting lines located between each section of six LEDs that are spaced every 50 mm.2. Peel back part of the tape on the back, and trim it off.3. Cover the cut end of the light with silicone glue.4. Take the extra supplied silicone end cap, and put it on the end of the light. Press out excess glue.5. Clean the light of the excess glue.6. Allow twenty-four hours for the glue to dry.7.
March 08, 2024 WLF12 Flexible LED Strip Light Instruction Manual © Banner Engineering Corp. All rights reserved. Chapter Contents Before installation: gather all supporting parts and accessories and remove power from the light. Mounting InstructionsChapter 5 Clean the mounting surface. Ensure that the mounting surface and all other mounting installation parts are dry.1. Remove the protective liner from the tape on the back of the light strip.2. Align the light strip in the desired installation position, and press the light strip firmly onto the mounting surface. After installing the light strip, wait twenty-four hours for the tape to adhere completely to the mounting surface. Do not touch or move the light strip during this time period. Connect the light strip to the power cable.4.
March 08, 2024 WLF12 Flexible LED Strip Light Instruction Manual © Banner Engineering Corp. All rights reserved. Confirm that the installation is fastened, the wiring is correct, and that the waterproof connecting wire for docking is tightened. Apply power to the light.6.
March 08, 2024 WLF12 Flexible LED Strip Light Instruction Manual © Banner Engineering Corp. All rights reserved. Chapter Contents Supply Voltage
24 V DC (±10%)
Use only with a suitable Class 2 power supply (UL) or SELV power supply (CE) Supply Current Light Length Typical Current (A) at 25 °C Maximum Current (A) at -20 °C 300 mm 0.14 0.165 600 mm 0.28 0.33 1200 mm 0.56 0.66 2000 mm 0.933 1.1 3000 mm 1.4 1.65 4000 mm 1.867 2.2 Supply Protection Circuitry Protected against reverse polarity and transient voltages Connections 150 mm (6 in) PVC-jacketed cable with a 4-pin M12 male quick-disconnect connector Models with a quick-disconnect connector require a mating cordset Do not spray cable with high-pressure sprayer or cable damage will result. Operating Temperature Storage Temperature Environmental Rating Rated IP66, IP67, IP69K per DIN 40050-9 Suitable for damp locations per UL 2108 Do not spray cable with a high-pressure sprayer or cable damage will result. Vibration and Mechanical Shock Vibration: 10 Hz to 55 Hz, 1.0 mm peak-to-peak amplitude per IEC 60068-2-6 Shock: 15G 11 ms duration, half sine wave per IEC 60068-2-27 Construction Clear silicone outer housing and end caps Internally silicone-encapsulated LEDs Very high-bonding strength tape and protective liner pre- applied to the back of the light Application Notes When cutting the WLF12, it is important to use the extra end cap supplied along with silicone glue. See "Cutting Instructions" on page 6. Cutting the WLF12 voids the Limited Warranty. For indoor or outdoor use, if exposure to direct sunlight is avoided. Do not use in applications with repeated flexing. Minimum Bend Radius 15 mm Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (A) Supply Wiring (AWG) Required Overcurrent Protection (A) 20 5.0 26 1.0 22 3.0 28 0.8 24 1.0 30 0.5 Mounting Use pre-applied, very high-bonding strength tape to mount the WLF12 without mounting brackets, see "Mounting Instructions" on page 7 If needed, use mounting bracket LMBWLF12C, see "Mounting Accessories" on page 11 Certifications Banner Engineering BV Park Lane, Culliganlaan 2F bus 3
1831 Diegem, BELGIUM
Turck Banner LTD Blenheim House Blenheim Court Wickford, Essex SS11 8YT GREAT BRITAIN SpecificationsChapter 6
March 08, 2024 WLF12 Flexible LED Strip Light Instruction Manual (1) Values shown at 25 °C. Current and lumen values decrease 0.4% per 1 °C from ambient. For example, an 1200 mm unit will have a maximum current of 0.66 A at -20 °C and 0.515 A at +45 °C. © Banner Engineering Corp. All rights reserved. Light Characteristics Daylight White Color Temperature (CCT): 5000K (± 300K) CRI: 80, min. LED Pitch: 8.33 mm Beam Angle: 120° Light Length Lumens (Typical at 25 °C)(1) 300 mm 285 600 mm 570 1200 mm 1140 2000 mm 1900 3000 mm 2850 4000 mm 3800 Dimensions xxxxxxxxxxxxxxxxxxxxxx 14.8 6.4 M12 x 1.0 44 171 TAPE 12.8 INCLUDE EXTRA ENDCAP WITH EACH UNIT Models L1 L2
March 08, 2024 WLF12 Flexible LED Strip Light Instruction Manual © Banner Engineering Corp. All rights reserved. Chapter Contents Mounting Accessories LMBWLF12C Set of 10 clamp brackets Translucent silicone Designed for M3 or No. 4 mounting hardware 5.5 2X Ø2 Cordsets 4-Pin Threaded M12 Cordsets—Single Ended Model Length Style Dimensions Pinout (Female) MQDC-403 1 m (3.28 ft) Straight 44 Typ. ø 14.5 M12 x 1 7 mm 58 mm Ø5.2 mm 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Not used MQDC-406 2 m (6.56 ft) MQDC-410 3 m (9.8 ft) MQDC-415 5 m (16.4 ft) MQDC-430 9 m (29.5 ft) 4-Pin Threaded M12 Cordsets—Single Ended Model Length Style Dimensions Pinout (Female) MQDC-406RA 2 m (6.56 ft) Right-Angle 32 Typ. [1.26"] 30 Typ. [1.18"] ø 14.5 [0.57"] M12 x 1 7 mm 58 mm Ø5.2 mm 2 3 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Not used MQDC-415RA 5 m (16.4 ft) MQDC-430RA 9 m (29.5 ft) AccessoriesChapter 7
March 08, 2024 WLF12 Flexible LED Strip Light Instruction Manual © Banner Engineering Corp. All rights reserved. 4-Pin Threaded M12 Cordsets—Double Ended Model Length Style Dimensions Pinout MQDEC-401SS 0.31 m (1 ft) Male Straight/ Female Straight 40 Typ. [1.58"] ø 14.5 [0.57"] M12 x 1 44 Typ. [1.73"] ø 14.5 [0.57"] M12 x 1 Female Male 1 = Brown 2 = White 3 = Blue 4 = Black MQDEC-402SS 0.6 m (1.97 ft) MQDEC-403SS 0.91 m (2.99 ft) MQDEC-406SS 1.83 m (6 ft) MQDEC-412SS 3.66 m (12 ft) MQDEC-415SS 4.58 m (15 ft) MQDEC-420SS 6.10 m (20 ft) MQDEC-430SS 9.14 m (30.2 ft) Splitter Cordsets 4-Pin Threaded M12 Male to 5-Pin Threaded M12 Female Splitter Cordset Model Branches (Female) Wiring S15YB-M124-M124-0.2M L1, L2 2 × 0.2 m (7.9 in) TRUNK (MALE) BRANCH 2 (FEMALE) BRANCH 1 (FEMALE) M12 x 1 M12 x 1
March 08, 2024 WLF12 Flexible LED Strip Light Instruction Manual © Banner Engineering Corp. All rights reserved. 4-Pin Threaded M12 Splitter Cordsets—Flat Junction Model Branches (Female) Trunk (Male) Pinout CSB-M1240M1240 No branch No trunk Female Male 1 = Brown 2 = White 3 = Blue 4 = Black CSB-M1240M1241 2 × 0.3 m (1 ft) No trunk CSB-M1241M1241 0.31 m (1 ft) CSB-M1248M1241 2.44 m (8 ft) CSB-M12415M1241 4.57 m (15 ft) CSB-M12425M1241 7.60 m (25 ft) CSB-UNT425M1241 7.60 m (25 ft) Unterminated CSB-M1243M1243 2 × 1 m (3.28 ft) 1 m (3.28 ft) 44 Typ. [1.73"] 43.0 [1.69"] Ø14.5 [0.57"] M12 x 1 Ø14.5 [0.57"] 40 Typ. [1.58"] 18.0 [0.71"] Ø4.5 [0.18"] 35 [1.38"] M12 x 1 5-Pin Threaded M12 Splitter Cordset with Flat Junction—Double Ended Model Trunk (Male) Branches (Female) Pinout (Male) Pinout (Female) CSB4-M1251M1250 0.3 m (0.98 ft) Four (no cable) Branch 1 Branch 2 Branch 3 Branch 4 3 x 18 72 mm 2 x 19 32 mm Male Trunk Length 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray Junction Blocks R50-4M125-M125Q-P Molded Junction Block Four integral 5-pin M12 female quick-disconnect connectors One integral 5-pin M12 male quick-disconnect connector Parallel wiring R95-8M125-M125Q-P Molded Junction Block Eight integral 5-pin M12 female quick-disconnect connectors One integral 5-pin M12 male quick-disconnect connector Parallel wiring
March 08, 2024 WLF12 Flexible LED Strip Light Instruction Manual © Banner Engineering Corp. All rights reserved. Dimmers and Switches LC15T-127AL2RGQP In-line capacitive touch switch with M12 connectors On/Off control and illuminated indication Rated for up to 30 V DC and 4 A maximum output current Rugged and waterproof IP67 housing LC15T-127AP2RBGQ In-line capacitive touch switch with M12 connectors On/Off/Dimming control and illuminated indication Rated for up to 30 V DC and 4 A maximum output current Rugged and waterproof IP67 housing LC25T-AL2RGQ In-line capacitive touch switch with M12 connectors Used with 2-wire DC devices Rated for up to 30 V DC and 4 A maximum output current Low profile, rugged, water-resistant IP67 design LC25T-AP2RGBQ In-line capacitive touch switch with M12 connectors Used with 2-wire PWM-controlled devices Rated for up to 30 V DC and 4 A maximum output current Low profile, rugged, water-resistant IP67 design WLS28-2MQ 2-position in-line motion detector switch with M12 connectors Used with 2-wire DC LED lights Rated for up to 30 V DC and 4 A maximum output current IP50 housing WLS28-2PBQ 3-position in-line switch with M12 connectors Used with 3-wire DC LED lights Rated for up to 30 V DC and 4 A maximum output current IP50 housing
March 08, 2024 WLF12 Flexible LED Strip Light Instruction Manual © Banner Engineering Corp. All rights reserved. Power Supplies PSW-24-1
24 V DC, 1 A Class 2 UL Listed power supply
100 V AC to 240 V AC 50/60 Hz input
2 m (6.5 ft) PVC cable with M12 quick disconnect Includes Type A (US, Canada, Japan, Puerto Rico, Taiwan), Type C (Germany, France, South Korea, Netherlands, Poland, Spain, Turkey), Type G (United Kingdom, Ireland, Singapore, Vietnam), and Type I (China, Australia, New Zealand) AC detachable input plugs TYPE A TYPE G TYPE C TYPE I PSW-24-2
24 V DC, 2 A Class 2 UL Listed power supply
3.5 m (11.5 ft) PVC cable with M12 quick disconnect Includes Type A (US, Canada, Japan, Puerto Rico, Taiwan), Type C (Germany, France, South Korea, Netherlands, Poland, Spain, Turkey), Type G (United Kingdom, Ireland, Singapore, Vietnam), and Type I (China, Australia, New Zealand) AC detachable input plugs PSD-24-4 90 to 264 V AC 50/60 Hz input Includes a 1.8 m (6 ft) US style 5-15P input plug
24 V DC UL Listed Class 2 M12 connector output
4 A total current
March 08, 2024 WLF12 Flexible LED Strip Light Instruction Manual © Banner Engineering Corp. All rights reserved. Chapter Contents Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. Banner Engineering Corp Limited Warranty Chapter 8