TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V AC coil Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 57.00 USD Main Range TeSys Product or component type Contactor Product name TeSys K Device short name LC1K Device application Control Contactor application Motor control Complementary Utilisation category AC-4 AC-3 Poles description 3P Power pole contact composition 3 NO [Ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz Signalling circuit: <= 690 V AC 50/60 Hz [Ie] rated operational current 6 A<= 440 V AC AC-3 power circuit Control circuit type AC 50/60 Hz [Uc] control circuit voltage 24 V AC 50/60 Hz Motor power kW 1.5 kW 220...230 V AC 50/60 Hz AC-3 2.2 kW 380...415 V AC 50/60 Hz AC-3 3 kW 440 V AC 50/60 Hz AC-3 3 kW 480 V AC 50/60 Hz AC-3 3 kW 500...600 V AC 50/60 Hz AC-3 3 kW 660...690 V AC 50/60 Hz AC-3 1.5 kW 400 V AC 50/60 Hz AC-4 Auxiliary contact composition 1 NC [Uimp] rated impulse withstand voltage 8 kV Overvoltage category III Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications * Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price. Apr 27, 2021

[Ith] conventional free air thermal current

20 A 122 °F (50 °C) power circuit

10 A 122 °F (50 °C) signalling circuit

Irms rated making capacity 110 A AC power circuit NF C 63-110

110 A AC power circuit IEC 60947

110 A AC signalling circuit IEC 60947

Rated breaking capacity 110 A 415 V IEC 60947

110 A 440 V IEC 60947

80 A 500 V IEC 60947

110 A 220...230 V IEC 60947 110 A 380...400 V IEC 60947 70 A 660...690 V IEC 60947 [Icw] rated short-time withstand current 90 A 122 °F (50 °C) - 1 s power circuit

85 A 122 °F (50 °C) - 5 s power circuit

80 A 122 °F (50 °C) - 10 s power circuit

60 A 122 °F (50 °C) - 30 s power circuit

45 A 122 °F (50 °C) - 1 min power circuit

40 A 122 °F (50 °C) - 3 min power circuit

20 A 122 °F (50 °C) - >= 15 min power circuit

80 A - 1 s signalling circuit

90 A - 500 ms signalling circuit

110 A - 100 ms signalling circuit

Associated fuse rating 25 A gG <= 440 V power circuit

25 A aM power circuit

10 A gG signalling circuit IEC 60947

10 A gG signalling circuit VDE 0660

Average impedance 3 mOhm - Ith 20 A 50 Hz power circuit [Ui] rated insulation voltage Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14 Insulation resistance > 10 MOhm signalling circuit Inrush power in VA 30 VA 68 °F (20 °C)) Hold-in power consumption in VA 4.5 VA 68 °F (20 °C)) Heat dissipation 1.3 W Connections - terminals solder pins 1.5 x 0.9 mm Maximum operating rate 3600 cyc/h Auxiliary contacts type type instantaneous 1 NC Signalling circuit frequency <= 400 Hz Minimum switching current 5 mA signalling circuit Minimum switching voltage 17 V signalling circuit Mounting support Printed circuit boards Operating time 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 Non overlap distance 0.02 in (0.5 mm) Mechanical durability 10 Mcycles Electrical durability 1.3 Mcycles 6 A AC-3 <= 440 V Mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Height 2.28 in (58 mm) Width 1.77 in (45 mm) Depth 2.24 in (57 mm)

Net weight 0.40 lb(US) (0.18 kg) Environment Standards BS 5424 IEC 60947 NF C 63-110 VDE 0660 Product certifications UL CSA IP degree of protection IP2x VDE 0106 Protective treatment TC conforming to IEC 60068 TC conforming to DIN 50016 Ambient air temperature for storage -58…176 °F (-50…80 °C) Operating altitude 2000 m without derating Flame retardance V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 Ordering and shipping details Category 22326 - CTR,K-LINE,AC,OPEN,NONREV Discount Schedule I12 GTIN 03389110488159 Nbr. of units in pkg. 1 Package weight(Lbs) 0.46 lb(US) (0.21 kg) Returnability No Country of origin FR Packing Units Unit Type of Package 1 PCE Package 1 Height 1.89 in (4.8 cm) Package 1 width 2.44 in (6.2 cm) Package 1 Length 2.68 in (6.8 cm) Unit Type of Package 2 S02 Number of Units in Package 2 50 Package 2 Weight 23.08 lb(US) (10.468 kg) Package 2 Height 5.91 in (15 cm) Package 2 width 11.81 in (30 cm) Package 2 Length 15.75 in (40 cm) Unit Type of Package 3 P06 Number of Units in Package 3 800 Package 3 Weight 387.53 lb(US) (175.78 kg) Package 3 Height 30.31 in (77 cm) Package 3 width 31.50 in (80 cm) Package 3 Length 23.62 in (60 cm) Offer Sustainability Sustainable offer status Green Premium product California proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov REACh Regulation REACh Declaration REACh free of SVHC Yes EU RoHS Directive Compliant EU RoHS Declaration

Toxic heavy metal free Yes Mercury free Yes RoHS exemption information Yes China RoHS Regulation China RoHS declaration Pro-active China RoHS declaration (out of China RoHS legal scope) Environmental Disclosure Product Environmental Profile Circularity Profile End of Life Information WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. Contractual warranty Warranty 18 months