RRoottaarryy IIssoollaattoorrss

33 PPoolleess

Newark.com/multicomp-pro Farnell.com/multicomp-pro sg.element14.com/b/multicomp-pro Page <1> 02/05/23 V1.1 LBPM 25 to 63A: LBDI 25 to 63A: Specifications: Features: LBPM 25 to 63A:

  • Degree of protection IP65
  • Panel mount
  • 2-hole rear mounting
  • Operable from the front (door) coupled with the door mechanism
  • Switch with the round padlocking device to prevent the switch from being switched on by unauthorized personnel. (The maximum number of padlocks that can be used is 3) LBDI 25 to 63A:
  • Degree of protection IP65
  • DIN rail mount
  • Metal shaft 280mm
  • 2-hole rear mounting or Snap-On mounting to 35mm DIN rail
  • Operable from the front (door) coupled with the door mechanism
  • Door interlock (door opens only in the OFF position). Rigid metal shaft/switch assembly
  • Switch with the padlocking device to prevent the switch from being turned to the on position by unauthorized personnel. (The maximum number of padlocks that can be used is 3)
  • Adjustable mounting by cutting the metal shaft to the appropriate length to suit panel height Canadian Standards : CAN / CSA-C22.2 No.14 American Standards : UL508 IEC and European Standards : IEC 60947-1 and 3, EN60947, VDE 0660-107 Specification Table: Isolator Rating (AC-21) Measure Switch Code LB25 LB32 LB40 LB63 LB80 LB100 LB125 Rated Operational Voltage, UE IEC / EN / VDE Volts V 690 690 690 690 690 690 690 UL / CSA 600 600 600 600 600 600 600 Main Switch: Isolating Voltage up to 750 750 750 750 750 750 750 Resistance to Surge Pulse Voltage, Uimp KV 6 6 6 6 6 6 6 Rated Uninterrupted Current, Iu Amperes A 20 25 32 40 63 100 125 Rated Uninterrupted Current, Ie IEC / EN / VDE AC - 22 Amperes A 20 25 32 40 63 100 125 AC - 21A 25 32 40 63 80 AC - 1 UL / CSA 20 25 32 40 63

RRoottaarryy IIssoollaattoorrss Newark.com/multicomp-pro Farnell.com/multicomp-pro sg.element14.com/b/multicomp-pro Page <2> 02/05/23 V1.1 Isolator Rating (AC-21) Measure Switch Code LB25 LB32 LB40 LB63 LB80 LB100 LB125 Rated Operational Power at 50 to 60 Hz (IEC / EN / VDE) IEC / EN / VDE AC - 23A,

3 Phase,

3 Poles

4 5.5 7.5 11 15 22 30 380 - 440V 7.5 11 15 18.5 37 45 500 - 690V 11 22 45 55 AC - 3A, 220 - 240V 3 4 5.5 7.5 11 18.5 22 380 - 440V 5.5 7.5 11 18.5 22 30 37 500 - 690V 7.5 11 37 45 Short Circuit Capacity (IEC / EN / VDE) Maximum Fuse Size (Type gL) Amperes A 25 25 32 40 63 100 125 Rated Fused Short Circuit Current kA 5 30 30 30 30 30 30 UL / CSA Power Rating DOL 1.5 3 3 5 7.5 7.5 7.5 240V 3 7.5 7.5 10 15 15 15 480V 7.5 15 20 20 25 30 40 600V 10 20 25 30 30 40 50 1 Phase 120V 0.5 1.5 2 3 4.5 3 3 240V 1.5 2 3 4 6 7.5 7.5 Short Circuit Capacity (UL / CSA) Maximum Fuse Size Amperes A 25 50 50 70 70 100 125 Fuse (Being Certified with J Type Fuses) Type - J J, RK5 J J Rated Fuse Short Circuit Current Amperes kA 5 5 5 5 5 10 10 Terminal Cross Section Single / Multiple Strand Wire Minimum mm2 1.5 1 1 4 4 6 6 Maximum 6 10 10 16 16 70 70 Fine Strand Wire with Sleeve Maximum 6 6 6 10 10 50 50 American Wire Gauge - AWG 12 8 8 6 6 1 1 Recommended Tightening

RRoottaarryy IIssoollaattoorrss Newark.com/multicomp-pro Farnell.com/multicomp-pro sg.element14.com/b/multicomp-pro Page <2> 02/05/23 V1.1 Isolator Rating (AC-21) Measure Switch Code LB25 LB32 LB40 LB63 LB80 LB100 LB125 Rated Operational Power at 50 to 60 Hz (IEC / EN / VDE) IEC / EN / VDE AC - 23A, 4 5.5 7.5 11 15 22 30 380 - 440V 7.5 11 15 18.5 37 45 500 - 690V 11 22 45 55 AC - 3A, 220 - 240V 3 4 5.5 7.5 11 18.5 22 380 - 440V 5.5 7.5 11 18.5 22 30 37 500 - 690V 7.5 11 37 45 Short Circuit Capacity (IEC / EN / VDE) Maximum Fuse Size (Type gL) Amperes A 25 25 32 40 63 100 125 Rated Fused Short Circuit Current kA 5 30 30 30 30 30 30 UL / CSA Power Rating DOL 1.5 3 3 5 7.5 7.5 7.5 240V 3 7.5 7.5 10 15 15 15 480V 7.5 15 20 20 25 30 40 600V 10 20 25 30 30 40 50 1 Phase 120V 0.5 1.5 2 3 4.5 3 3 240V 1.5 2 3 4 6 7.5 7.5 Short Circuit Capacity (UL / CSA) Maximum Fuse Size Amperes A 25 50 50 70 70 100 125 Fuse (Being Certified with J Type Fuses) Type - J J, RK5 J J Rated Fuse Short Circuit Current Amperes kA 5 5 5 5 5 10 10 Terminal Cross Section Single / Multiple Strand Wire Minimum mm2 1.5 1 1 4 4 6 6 Maximum 6 10 10 16 16 70 70 Fine Strand Wire with Sleeve Maximum 6 6 6 10 10 50 50 American Wire Gauge - AWG 12 8 8 6 6 1 1 Recommended Tightening RRoottaarryy IIssoollaattoorrss Newark.com/multicomp-pro Farnell.com/multicomp-pro sg.element14.com/b/multicomp-pro Page <3> 02/05/23 V1.1 Drawing Notes: Dimensions in mm Drawn to Scale

RRoottaarryy IIssoollaattoorrss Newark.com/multicomp-pro Farnell.com/multicomp-pro sg.element14.com/b/multicomp-pro Page <4> 02/05/23 V1.1 (AC - 21 A and AC - 1) Important Notice : This data sheet and its contents (the “Information”) belong to the members of the AVNET group of companies (the “Group”) or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it relates. No licence of any inte llectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes n o responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data s heet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Inf ormation or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group’s liability for death or personal injury resulting from its negligence. Multicomp Pro is the registered trademark of Premier Farnell Limited 2019. Diagram: LBPM 25 to 63A: LBDI 25 to 63A: Part Number Explanation: LB DI / PM 25 3P Dimensions: Millimeters Load Break Door Interlock / Panel Mount Current Rating Number of Poles Door Interlock / Panel Mount : DI = Door Interlock and PM = Panel Mount Current Rating : 25 = 25A, 32 = 32A, 40 = 40A, 63 = 63A, 80 = 80A, 100 = 100A and 125 = 125A Number of Poles : 3P = 3 Poles Part Number Table Description Part Number Isolator Interlock 25A 3P LBDI253P Isolator Interlock 32A 3P LBDI323P Isolator Interlock 40A 3P LBDI403P Isolator Interlock 63A 3P LBDI633P Isolator Interlock 80A 3P LBDI803P Isolator Interlock 100A 3P LBDI1003P Isolator Interlock 125A 3P LBDI1253P Isolator Panel Mount 25A 3P LBPM253P Isolator Panel Mount 32A 3P LBPM323P Isolator Panel Mount 40A 3P LBPM403P Isolator Panel Mount 63A 3P LBPM633P