LB115 SLPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 8

Technical content

Features

/square4 Small size of 2” x 4” x 1.3” /square4 75W convection cooled/115 Watts with 200 LFM /square4 Universal Input 90-264Vac /square4 Meets EN55015 Conducted EMI /square4 Meets IEC61000-3-2 Class C for less than 1 Watt to full power /square4 Approved to UL/CSA/IEC/EN60950-1, 2 nd Edition /square4 Level V Efficiency Compliant /square4 -40˚C start up /square4 -20˚C to 70˚C Operating temperature Range /square4 3 Year Warranty /square4 Optional LED indicator for power-on

Description

The LB115S LED Series provide a reliable power source with high power density in 2” x 4” x 1.3” packag e. Fully compliant to the applicable safety and Global Lighting EMC standards, these models will allow easy integration into many Lighting fixtures and other industrial applications. All 4 models are CE marked to low voltage directive and approved to standards of UL/CSA/IEC/EN60950-1 2nd edition. Model Selection Model Output Current Output Current Ripple & Total OVP Number Volts Convection Cooled Forced air(200 LFM) (Total Power) Noise* Regulation Threshold LB115S12K 12 V 6.25 A 9.00A (108 Watts) 0.5%RMS, 1.5% pk-pk ±2% 14.0 ± 1.1V LB115S24K 24 V 3.13A 4.58A (110 Watts) 0.5%RMS, 1% pk-pk ±2% 28.0 ± 2.5V LB115S48K 48 V 1.56A 2.40A (115 Watts) 0.5%RMS, 1% pk-pk ±2% 55.0 ± 4.0V LB115S56K 56 V 1.34A 2.05A (115 Watts) 0.5%RMS, 1% pk-pk ±2% 63.0 ± 4.0V Notes: * At -20C, the noise and ripple is 2% of the output. General & Input Specifications PARAMETER SPECIFICATION NOTES AC Input Voltage: 90-264Vac, single phase AC Input Frequency: 47-63Hz AC Input Current: 115Vac: 2A, 230Vac: 1A Inrush Current: 65A maximum @ 25C Earth Leakage Current (Input–Earth): <350 u A @264Vac, 60 Hz input, NC Input Fuse: F1:4A, 250VAC Fuse provided on all models

www.slpower.com LB115S 2-OCT-14 2 Efficiency Typical Measured @ 25˚C LB115S12K 89% @230V ac, full load 86.5%@115V ac, full load LB115S24K 89% @230V ac, full load 87%@115V ac, full load LB115S48K 90% @230V ac, full load 88%@115V ac, full load LB115S56K 90% @230V ac, full load 88%@115V ac, full load Operating Temperature -20˚C to 70˚C -40˚C start up (full load) For 12V output, the maximum load is 75% Storage Temperature -40˚C to 85˚C Turn-on Time: <2 Seconds @115Vac(<3S for 12V output) <5 Seconds @115Vac for -20˚C ambient Hold-up Time: 12mS minimum from loss of ac input at

115 Vac

PARAMETER SPECIFICATION NOTES Output Power: Max of 75 Watts for Convection cooled Maximum 108 Watts for 12V output -20 to 50˚C ambient Max of 115 Watts for fan cooled (48 & 56V Models) Cooling: Convection Forced Air of 200 LFM Total Regulation: ±2% for all models Total regulation is the maximum deviation from nominal voltage for all loading conditions Overload Protection: 120% - 180% of rated output current value, Hiccup Mode For 12V output, it is 110 to 180% Short Circuit Protection: Short across the output terminals will not cause damage to the unit. Hiccup Mode Overvoltage Protection: OVP firing reduces output voltage to <50% of nominal in <50mS. See chart for trip range Overtemperature Protection: Automatic Power Shutdown Thermistor temperature is 130˚C Minimum Load: No minimum load is required Ripple and Noise: 0.5% RMS, 1% pk-pk for all models. 20 MHz Bandwidth, differential mode. Measured with noise probe directly across output terminals, and load terminated with 0.1 µF ceramic and 10 µF low ESR capacitors Transient Response: 500 µ s typ. response time for return to within 0.5% of final value for a 50% load change, ∆ i/ ∆ t< 0.2A/ µ s. Max. voltage deviation is 3.5%. Measured @ 25˚C Overshoot: 5% overshoot at turn-on, 5% overshoot at turn-off, under all conditions. 6% for 12V output

www.slpower.com LB115S 2-OCT-14 3 Safety Standard Compliance Agency CONDITIONS UL EN/CSA/UL/IEC 60950-1, 2 nd Edition CSA CSA 60950-1, 2 nd Demko EN 60950-1, 2nd CB Report IEC 60950-1, 2nd Isolation Type: Double/Reinforced between Input and Output Isolation Specifications PARAMETER CONDITIONS Rating NOTES Insulation Safety Rating: Input to Ground Basic Insulation Input to Output Double/Reinforced Electric Strength Test Voltage: Input to Ground 1900Vac Input to Output 3000Vac Output to Ground 500Vac . Environmental Specifications PARAMETER SPECIFICATION NOTES Operating Temperature: -20° C to +70° C -40° C Startup guaranteed Temperature Derating: 6 0 % derating at 70° C Cooling: Convection/ Airflow 75 Watts convection Storage Temperature: -40° C to +85° C Altitude: Operating: -500 to 3,000 meter Non-operating: -500 to 40,000 ft. Relative Humidity: 5% to 95%, non-condensing Shock: Non-Operating: Half-sine, 40 gpk, 10mS, 3 axes, 6 shocks total Vibration: Random vibration per MIL-STD-810E, Method 514.4, Cat. 1, Figure 514.4-1, 1 hr in each of three axes Reliability Specifications PARAMETER SPECIFICATION NOTES MTBF: 574K hours, 25° C ambient, full load Calculation is done based on Telcordia. Reports for each model is available Warranty: 3 Years Limited HALT Data: Per SL Power Halt procedure Report is av ailable

www.slpower.com LB115S 2-OCT-14 4 EMI/EMC Compliance PARAMETER SPECIFICATION NOTES Conducted Emissions: EN55011/22 Class B; FCC Part 15 Also meets EN55015 Class B Radiated Emissions: EN55011/22 Class A; FCC Part 15 Harmonic Current Emissions EN61000-3-2, Class A,B,C &D Meets class C from 5 to 115 Watts. This is based on limits set @ 115 Watt Voltage Fluctuations & Flicker EN61000-3-3 Static Discharge Immunity: EN61000-4-2, Level 4: 6kV contact, 8kV air, Criteria A Performance criteria are defined as following: A – Normal performance during and after the test B – Temporary degradation, self-recoverable C – Temporary degradation, operator intervention required to recover the operation RF Field Susceptibility EN61000-4-3, Level 3 (3V/m), Criteria A Fast Transients/Bursts EN61000-4-4, Level 3 (PS: 2kV-40A, other lines 1kV-20A), Criteria A Surge susceptibility EN61000-4-5, Installation Class 3 (1kV diff. mode, 2kV common mode), Criteria A Conducted RF susceptibility EN61000-4-6, Level 3 (3Vrms ), Criteria A Power Frequency Magnetic Field Test EN61000-4-8, Level 3 (3A/m), Criteria A Voltage Sags & Surges EN61000-4-11, 95% dip/0.5 cycle (Criteria A), 60%/5cycles (Criteria B ), 30%/25 cycles (Criteria A). loading is 70% of 100 watts with 100 Vac input. Notes: 1. Specifications subject to change without notice. 2. Specifications are for convection rating at factory settings with 115Vac input and 25° C ambient unless otherwise stated.

www.slpower.com LB115S 2-OCT-14 5 Mechanical Drawing Connector Information Input Connector DC Output Connector Ground (FG)J1 PIN 1) AC NEUTRAL PIN 2) EMPTY PIN 3) AC LINE PIN 1) +Vout PIN 2) +Vout PIN 3) +Vout PIN 4) -Vout PIN 5) -Vout PIN 6) -Vout 19-30258-0187 (Keystone 1285) (Zierick 895)(.187*0.020) Mating Connector: Tyco/AMP 640250-3 Terminals : 3-640252-1 Mating Connector: AMP 640250-6 Terminals : 3-640252-1 Mating Connector Molex 190020005 1. All dimensions in inches (mm) undefined tolerance is ±.02” (0.5mm). 2. Mounting holes should be connected together for EMI purpose 3. FG is safety ground connection 4. This power supply requires mounting on metal standoffs 0.20” (5mm) Min. in height

www.slpower.com LB115S 2-OCT-14 6 Characteristic Curves Output Power vs. Temperature Efficiency vs. Loading

www.slpower.com LB115S 2-OCT-14 7 Ripple & Noise To verify that the output ripple and noise does not exceed the level specified in the product specification, measured using a scope probe socket with 0.1uF ceramic and a 10uF electrolytic capacitor connected in parallel across it, 20MHz BW. Output Overload Characteristic Overvoltage Protection

www.slpower.com LB115S 2-OCT-14 8 Turn On Time Hold Up Time Data Sheet © 2014 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice . CH1: Vout Vin: 115 Vac CH3: Vin Iout: 2.40 Amps Min_Limit: 16 Meas: 23.2 mS