UNISONIC TECHNOLOGIES CO., LTD L8562 LINEAR INTEGRATED CIRCUIT w w w . u n i s o n i c . c o m . t w 1 of 6 Copyright © 2011 Unisonic Technologies Co., LTD QW-R119-018.C POWER FACTOR CORRECTOR DESCRIPTION The UTC L8562 is a Power Factor Corrector, which can work in wide input voltage range applications (from 85V ~ 265V) with an excellent THD. It has very low start up current (about 20 uA) and a disable function on the ZCD pi n, which is designed to keep lower current consumption in stand by mode. The device is operating in transit ion mode, and is able to drive a Power MOS or IGBT with a ± 400mA current for sourcing and sinking. FEATURES * 1% Precision (@ TJ = 25℃) Internal Reference Voltage * Output Overvoltage Protection * Very Low Power Start-Up Current * Current Sense Filter On Chip * Disable Function (with ZCD pin) * Transition Mode Operation * Gate Driving Current: ± 400mA * 15V Gate clamped ORDERING INFORMATION Ordering Number Package Packing Lead Free Halogen Free L8562L-D08-T L8562G-D08-T DIP-8 Tube L8562L-S08-R L8562G-S08-R SOP-8 Tape Reel L8562L-S08-T L8562G-S08-T SOP-8 Tube
L8562 LINEAR INTEGRATED CIRCUIT UNISONIC TECHNOLOGIES CO., LTD 2 of 6 www.unisonic.com.tw QW-R119-018.C PIN CONFIGURATION PIN DESCRIPTION PIN NO PIN NAME DESCRIPTION 1 INV Inverting input of the error amplifier. 2 COMP Output of t he error amplifier. 3 MULT Input of t he multiplier stage. 4 CS Input of the cu rrent sense stage. 5 ZCD Input of the zero current detection . 6 GND Ground. 7 GD Gate driver output. 8 V CC Voltage supply. BLOCK DIAGRAM
L8562 LINEAR INTEGRATED CIRCUIT UNISONIC TECHNOLOGIES CO., LTD 3 of 6 www.unisonic.com.tw QW-R119-018.C ABSOLUTE MAXIMUM RATING (TA=25℃, unless otherwise specified) PARAMETER SYMBOL RATINGS UNIT Analog Inputs & Outputs INV, COMP MULT -0.3 ~ 7 V Current Sense Input CS -0.3 ~ 7 V Iq+Iz (IGD = 0) IV CC 30 mA Output Totem Pole Peak Current (2ms) I GD ±700 mA Zero Current Detector ZCD 50 (source) -10 (sink) mA mA Power Dissipation @ TA=50℃ SOP-8 PD 1 W DIP-8 0.65 W Junction Temperature T J 125 ℃ Operating Temperature T OPR -20 ~ +85 ℃ Storage Temperature T STG -40 ~ +150 ℃ Note 1. Absolute maximum ratings are those values beyond which the device could be permanently damaged. Absolute maximum ratings are stress ratings only and functional device operation is not implied. 2. The device is guaranteed to meet performance specification within 0 ℃~70 ℃ operating temperature range and assured by design from –20℃~85℃. ELECTRICAL CHARACTERISTICS (VCC=12V, TA=-25 ℃ ~ 125℃, unless otherwise specified) PARAMETER PIN SYMBOL TEST CONDITIONS MIN TYP MAX UNIT SUPPLY VOLTAGE SECTION Operating Range 8 V CC after turn-on 11 18 V Turn-on Threshold 8 V CC(ON) 14 15.3 16.5 V Turn-off Threshold 8 V CC OFF 7.2 7.9 8.7 V Hysteresis 8 Hys 6.5 8.3 V SUPPLY CURRENT SECTION Start-up Current 8 I START-U V CCON-1V 30 50 A Quiescent Current 8 Iq 6 9 mA Operating Supply Current 8 I CC CL=1nF @ 70KHz 10 15 mA In OVP condition Vpin1=2.7V 6.8 mA Quiescent Current 8 Iq VPIN5150mA, VCC>VCC off 6 mA
8 V PIN5150mV, VCC<VCC off 4 7 10 A
Zener Voltage 8 V Z I CC=20mA 18 21 24 V ERROR AMPLIFIER SECTION Voltage Feedback Input Threshold 1 V INV TA=25℃ 2.465 2.5 2.535 V 10.3V<VCC<18V 2.44 2.56 V Line Regulation V CC=10.3 ~ 18V 3 5 mV Input Bias Current 1 I INV -0.1 -1 A Voltage Gain G V Open loop 60 80 dB Gain Bandwidth G B 0.8 MHz Source Current 2 I COMP VCOMP=4V, VINV=2.4V -2 -4 -8 mA Sink Current V COMP=4V, VINV=2.6V 2.5 4.5 mA Upper Clamp Voltage 2 V COMP ISOURCE=0.5mA 4.5 5 5.5 V Lower Clamp Voltage I SINK=0.5mA 2.25 2.4 2.55 V MULTIPLIER SECTION Linear Operating Voltage 3 V MULT 0~ 2.5 0 ~ 3.5 V Output Max.Slope V△ CS V△ MULT VMULT=from 0V ~ 0.5V VCOMP=Upper Clam Voltage 1.65 1.9 Gain K V MULT=1V, VCOMP=4V 0.5 0.7 0.9 1/V
L8562 LINEAR INTEGRATED CIRCUIT UNISONIC TECHNOLOGIES CO., LTD 4 of 6 www.unisonic.com.tw QW-R119-018.C ELECTRICAL CHARACTERISTICS(Cont.) PARAMETER PIN SYMBOL TEST CONDITIONS MIN TYP MAX UNIT CURRENT SENSE COMPARATOR Current Sense Reference Clamp 4 V CS VMULT=2.5V VCOMP=Upper Clamp Voltage 1.6 1.7 1.8 V Input Bias Current 4 I CS V OS=0 -0.05 -1 A Delay to Output 4 t D(H-L) 200 450 ns ZERO CURRENT DETECTOR Input Threshold Voltage Rising Edge 5 VZCD (Note) 2.1 V Hysteresis (Note) 0.4 0.6 0.8 V Upper Clamp Voltage 5 V ZCD I ZCD=20A 5.9 6.5 7.3 V Upper Clamp Voltage 5 V ZCD I ZCD=2.5mA 6.1 6.6 7.5 V Lower Clamp Voltage 5 V ZCD I ZCD=-2.5mA 0.3 0.7 1 V Sink Bias Current 5 I ZCD 1V V ≦ ZCD 4.5V≦ 2 A Source Current Capability 5 I ZCD -3 -10 mA Sink Current Capability 5 I ZCD 3 10 mA Disable threshold 5 V DIS 100 200 300 mV Restart Current After Disable 5 I ZCD V ZCD<VDIS, VCC>VCCOFF -20 -50 A OUTPUT SECTION Dropout Voltage 7 V GD IGD(SOURCE)=200mA 1.2 2 V IGD(SOURCE)=20mA 0.8 1.2 V IGD(SINK)=200mA 1.2 1.9 V Output Voltage Rise Time 7 t R C L=1nF 40 100 ns Output Voltage Fall Time 7 t F C L=1nF 40 100 ns IGD Sink Current 7 I GD(OFF) VCC=3.5V, VGD=1V 10 40 mA OUTPUT OVERVOLTAGE SECTION OVP Triggering Current 2 I OVP 30 40 50 A Static OVP Threshold 2.25 2.4 2.55 V RESTART TIMER Start Timer t START 70 130 300 s Note: Parameter guaranteed by design, not tested in production.
L8562 LINEAR INTEGRATED CIRCUIT UNISONIC TECHNOLOGIES CO., LTD 5 of 6 www.unisonic.com.tw QW-R119-018.C TYPICAL APPLICATION CIRCUIT 150W, Wide-range mains ZCD COMP INV GD CSGND MULT VCC ~ VAC (90V~264V) F1 3 2.0A/250V BD1 2KBP06M 1μF/ 400V 620K/ 1206 620K/ 1206 R14 10K/ 0805 10nF/ 0805 22μF/50V ZD1 ZD18.0 52 1 62K/1206 56K/1206 R3 110/ 0805 10nF/0805 D2 1N4148 T1 PFC CHOKE 11 7 2 6 R5 10K/0805 1μF/0805 R13 D3 1N4148 12N65 R16 0.47/1W R17 0.47/1W R11 19K/ 0.25W R12 19K/ 0.25W 120μF/ 450V 750K/1206 750K/1206 BYC5-600 22K/1206 UTC L8562
L8562 LINEAR INTEGRATED CIRCUIT UNISONIC TECHNOLOGIES CO., LTD 6 of 6 www.unisonic.com.tw QW-R119-018.C TYPICAL CHARACTERISTICS Output ripple at 0.5W Time (2s/div) 01 0 2 0 VIN=90V 100V100V/div Time (2s/div) 01 0 2 0 VIN=115V 100V100V/div Time (2s/div) 01 0 2 0 VIN=230V 100V100V/div Time (2s/div) 01 0 2 0 VIN=264V 100V100V/div UTC assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all UTC products described or contained herein. UTC products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice.