L2044 UTC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
UNISONIC TECHNOLOGIES CO., LTD L2044 LINEAR INTEGRATED CIRCUIT www.unisonic.com.tw 1 Copyright © 2005 Unisonic Technologies Co., LTD QW-R123-015,A DUAL OUTPUT FLASHER DESCRIPTION The UTC L2044 is a dual output stages flasher designed as a relay driver for flashing light c ontrol in automotive applications. Both sides direction indicator input with only a small control current makes switch contacts for small lo ads possible. Each side of the vehicle is controlled separately. The construction of the hazard sw itch could be simplified due to hazard warning input is separate. The flasher will dramatically increase the flash frequency by a typica l ratio of 2:1 if lamp fault is detected. The UTC L2044 can be directly connected to the battery due to extreme low current consumption FEATURES * Temperature and Supply Voltage Compensated Flashing Frequency * Frequency Doubling Indicates Lamp Fault. * Two Relay Driver Outputs with High Current-carrying Capacity and Low Saturation Voltage * Minimum Lamp Load for Flasher Operation: ≥ 1W * Very Low Sensitivity to EMI * Extremely Low Current Consumption<10µA ( at Switches Open) * Reverse Polarity Protection * Three Control Inputs: Left, Right and Hazard Warning DIP -14 SOP-14 *Pb-free plating product number: L2044L PIN DESCRIPTION PIN No. PIN NAME FUNCTION
1 OSC Oscillator
2 SIL Start input left
3 SIR Start input right
4 SIHW Start input hazard
5 VS V CC
6 CR1 Control input relay 1
7 CR2 Control input relay 2
8 LD Lamp failure detection
9 VS V CC
10 GND ground
11 OR1 Output relay 1
12 VS V CC
13 OR2 Output relay 2
14 OSC Oscillator
ORDERING INFORMATION Order Number Normal Lead free Package Packing L2044-D14-T L2044L-D14-T DIP-14 Tube L2044-S14-R L2044L-S14-R SOP-14 Tape Reel L2044-S14-T L2044L-S14-T SOP-14 Tube
L2044 LINEAR INTEGRATED CIRCUIT UNISONIC TECHNOLOGIES CO., LTD 2 www.unisonic.com.tw Q W - R 1 2 3 - 0 1 5 , A PIN CONFIGURATION
14 OSC
13 OR2
11 OR1
10 GND
8 LD7CR2
BLOCK DIAGRAM Vcc-81mV 8 VRef1 VRef2 Vcc/2 423 4.7KƸ R10 1.2KƸ 4.7KƸ right left 1.2KƸ 1.2KƸ 4.7KƸ Relay 200Ƹ Hazard warning GND 101311 27.5V Vcc-6V 82KƸ 4.7DŽF 47KƸ 47KƸ7 Vcc Vstart GND RShunt 30mƸ Contast Vcc Vcc
L2044 LINEAR INTEGRATED CIRCUIT UNISONIC TECHNOLOGIES CO., LTD 3 www.unisonic.com.tw Q W - R 1 2 3 - 0 1 5 , A ABSOLUATE MAXIUM RATINGS PARAMETER SYMBOL RATINGS UNIT Supply Voltage, 1 min, pins 5, 9 and 12 V CC 24 V Junction Temperature T J +125 ¥ Operating Temperature T OPR 0Ċ~70Ċ ¥ Storage Temperature T STG -40 ~ +150 ¥ DIP-14 90 Thermal Resistance Junction to Ambient SOP-14 ǀJA 120 ¥/W Note 1.Absolute maximum ratings are those values beyond which the device could be permanently damaged. Absolute maximum ratings are stress ratings only and functional device operation is not implied. 2.The device is guaranteed to meet performance specification within 0 Ċ~70Ċoperating temperature range and assured by design from –20Ċ~85Ċ. ELECTRICAL CHARACTERISTICS (VCC = 12V, Ta =25¥, unless otherwise specified.) PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNIT Supply Voltage Range V CC Pins 5, 9, 12 8 18 V VCC=8V 1.0Saturation Voltage VCC=12V VOUT R L=82Ω 1.2 V Clamping Voltage V 12 Ta= -20¥ ~ 85¥ 25.0 27.5 30.0 V Relay output overvoltage detection (relay disabled) V 12 Ta= -20¥ ~ 85¥ 18 20 22 V Control signal threshold V CC VCC=9V VCC=13.5V VCC=16V 70.6 85.5 93.0 mV Output current for relay driver I OUT Pins 11, 13 300 mA Relay output reverse current I OUT Pins 11, 13 0.1 mA Supply current, switches open I CC Pins 5, 9, 12 10 µA Relay coil resistance R L Ω Start delay t ON First bright phase 10 ms Tolerance of control signal threshold VCC=9V~16V, Pin 8, Temperature coefficient of control signal Threshold T CVO V CC=13.5V, Pin 8 10 µV/K TOLERANCES (VCC = 12V, Ta =25¥, unless otherwise specified.) PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNIT Frequency determining resistor R 1 6.8 510 k Ω Frequency determining capacitor C 1 47 µF Frequency tolerance ¶f1 Normal flashing, basic frequency f1 excluding the tolerance of R1 and C1 -5 +5 % ¶f1 Basic frequency f1 47 53Bright period ¶f2 Control frequency f2 37 45 % Frequency increase f2 Lamp failure 2.15×f 1 2.3×f 1 Hz Lamp load P L 1 W UTC assumes no responsibility for equipment failures t hat result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all UTC products described or contained herein. UTC products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice.