VA75-NM-NM-60 ROSENBERGER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

RPC-N 75 Ω / RPC-N 75 Ω VA75-NM-NM-60 Rosenberger Hochfrequenztechnik GmbH & Co. KG P.O.Box 1260 D-84526 Tittmoning Germany www.rosenberger.de Tel. : +49 8684 18-0 Email : info@rosenberger.de Page Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG RF_35/09.14/6.2

Contents

Device Part number Quantity Cable assembly RPC-N 75 Ω plug / RPC-N 75 Ω plug L20-001-600 2 Assembly parts Technical data sheet cable assembly: RPC- N 75 Ω plug / RPC-N 75 Ω plug L20-001-XXX

RPC-N 75 Ω / RPC-N 75 Ω VA75-NM-NM-60 Rosenberger Hochfrequenztechnik GmbH & Co. KG P.O.Box 1260 D-84526 Tittmoning Germany www.rosenberger.de Tel. : +49 8684 18-0 Email : info@rosenberger.de Page Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG RF_35/09.14/6.2 Electrical data Impedance 75 Ω Frequency DC to 4 GHz Return loss 1 ≥ 28 dB, DC to 3 GHz ≥ 23 dB, 3 to 4 GHz Insertion loss 1 ≤ 0.70 dB at 4 GHz Phase deviation: After 90° bending ≤ 2.5°, DC to 4 GHz Straight after 3x90° bending ≤ 1.5°, DC to 4 GHz Amplitude stability ≤ 0.03 dB, DC to 4 GHz Return loss stability ≥ 42 dB, DC to 4 GHz Individual testing and documentation: Measurement plot with all 4 S-Parameters (S11; S22; S21; S12) is included with the cable assembly and on the backside the care and handling instruction is printed. Measurement adaptors used are mentioned in the commentary field.

1 Return Loss and Insertion Loss includes the measurement adaptor

Minimum bend radius: 50 mm Environmental data Temperature range -40°C to +80°C RoHS compliant Draft Date Approved Date Rev. Engineering change n umber Name Date Martin Moder 07/12/15 Herbert Babinger 08/12/15 e0 0 15-1612 M.Ruf 08/12/15 While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warr anty on our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our products, we reserve the right to make changes judged to be necessary.