L1HX-2770200000000 LUMILEDS | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 17
Technical content
No. E352519 DS288 LUXEON HL2X Product Datasheet ©2021 Lumileds Holding B.V. All rights reserved. LUXEON HL2X is a 2mm 2 CSP high power domed emitter designed specifically for outdoor and industrial applications like street lights and high bay luminaires. The package is optimized for directional lighting with emphasis on “usable light in application”. LUXEON HL2X delivers high efficacy and robustness in an industrial standard 3535 package with 3-stripe footprint. This is designed to accelerate time to market through compatibility with LUXEON TX optics, while improving system costs through superior performance (flux and efficacy). luXEon Hl2X Best performance. Most usable light. Proven package. FEaturEs and BEnEFIts PrImary aPPlIcatIons Most usable light in application with a design emphasis on Beam Angle, Field Angle, Color Over Angle, and Optical Efficiency performance Roadway Industrial / Warehouse CSP die technology enables high efficacy and high driving current capability in unique applications Area Sports Industry standard 3535 package with 3-stripe footprint and radiation pattern matched to LUXEON TX for ease of design Wall Grazer / Wall Wash Specialty DLC R9 enabled to offer best-in-class color quality for luminaires More…
DS288 LUXEON HL2X Product Datasheet 20210523 ©2021 Lumileds Holding B.V. All rights reserved. i Table of Contents
DS288 LUXEON HL2X Product Datasheet 20210523 ©2021 Lumileds Holding B.V. All rights reserved. 2 General Product Information Product Test Conditions LUXEON HL2X LEDs are tested and binned with a DC drive current of 700mA, at a junction temperature, Tj, of 85°C. Part Number Nomenclature Part numbers for LUXEON HL2X follow the convention below: L 1 H X – A A B B 2 0 0 0 0 0 0 0 0 Where: A A – designates nominal ANSI CCT (27=2700K, 30=3000K, 35=3500K, 40=4000K, 50=5000K, 57=5700K, 65=6500K) B B – designates minimum CRI (70=70CRI, 80=80CRI,90=90CRI) Therefore, the following part number is used for a LUXEON HL2X 3000K 70CRI LED: L 1 H X – 3 0 7 0 2 0 0 0 0 0 0 0 0 Note: Except for 2700K 70 CRI and 3500K 70 CRI, all LUXEON HL2X Parts are binned for meeting R9 specifications Lumen Maintenance Please contact your local Sales Representative or Lumileds Technical Solutions Manager for more information about the long- term performance of this product. Environmental Compliance Lumileds LLC is committed to providing environmentally friendly products to the solid-state lighting market. LUXEON HL2X is compliant to the European Union directives on the restriction of hazardous substances in electronic equipment, namely the RoHS Directive 2011/65/EU and REACH Regulation (EC) 1907/2006. Lumileds LLC will not intentionally add the following restricted materials to its products: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated diphenyl ethers (PBDE).
DS288 LUXEON HL2X Product Datasheet 20210523 ©2021 Lumileds Holding B.V. All rights reserved. 3 Performance Characteristics Product Selection Guide Table 1 . Product performance of LUXEON HL2X at 700mA, T j=85°C . nomInal cct mInImum r9 [3] mInImum crI [1] lumInous FluX [2] (lm) tyPIcal lumInous EFFIcacy (lm/W) Part numBErmInImum tyPIcal 700ma 2700K 70 260 280 141 L1HX-2770200000000 3000K ≥ -40 70 280 302 152 L1HX-3070200000000 3500K 70 290 310 156 L1HX-3570200000000 4000K ≥ -40 70 300 316 160 L1HX-4070200000000 5000K ≥ -40 70 300 316 160 L1HX-5070200000000 5700K ≥ -40 70 300 317 160 L1HX-5770200000000 6500K ≥ -40 70 290 318 161 L1HX-6570200000000 2700K ≥ 0 80 240 260 131 L1HX-2780200000000 3000K ≥ 0 80 240 267 135 L1HX-3080200000000 4000K ≥ 0 80 270 294 148 L1HX-4080200000000 5000K ≥ 0 80 270 293 148 L1HX-5080200000000 5700K ≥ 0 80 280 292 147 L1HX-5780200000000 2700K ≥ 50 90 190 210 106 L1HX-2790200000000 3000K ≥ 50 90 200 221 112 L1HX-3090200000000 3500K ≥ 50 90 210 232 117 L1HX-3590200000000 4000K ≥ 50 90 220 246 124 L1HX-4090200000000 5000K ≥ 50 90 230 251 127 L1HX-5090200000000 5700K ≥ 50 90 230 257 130 L1HX-5790200000000 Notes for Table 1: 1. Lumileds maintains a tolerance of ±2 on CRI. 2. Lumileds maintains a tester tolerance of ±6.5% on luminous flux measurements. 3. Lumileds maintains a tester tolerance of ±6.5 on R9 measurements. Optical Characteristics Table 2 . Optical characteristics for LUXEON HL2X at 700mA, T j=85°C . Part numBEr tyPIcal total IncludEd anglE [1] tyPIcal VIEWIng anglE [2] L1HX-xxxx200000000 160° 120° Notes for Table 2: 1. Total angle at which 90% of total luminous flux is captured. 2. Viewing angle is the off axis angle from the LED centerline where the luminous intensity is ½ of the peak value.Electrical and Thermal Characteristics Table 3 . Electrical and thermal characteristics for LUXEON HL2X at 700mA, T j=85°C . Part numBEr ForWard VoltagE [1] (Vf) tyPIcal tEmPEraturE coEFFIcIEnt oF ForWard VoltagE [2] (mV/°c) tyPIcal tHErmal rEsIstancE—JunctIon to soldEr Pad (°c/W)mInImum tyPIcal maXImum Notes for Table 3: 1. Lumileds maintains a tolerance of ±0.1V on forward voltage measurements. 2. Measured between 25°C and 110°C.
DS288 LUXEON HL2X Product Datasheet 20210523 ©2021 Lumileds Holding B.V. All rights reserved. 4 Absolute Maximum Ratings Table 4 . Absolute maximum ratings for LUXEON HL2X . ParamEtEr maXImum PErFormancE DC Forward Current [1, 2, 5] 2000mA 2500mA Peak Pulsed Forward Current [1, 3] 2500mA 2500mA LED Junction Temperature [1] (DC & Pulse) 135°C 125°C ESD Sensitivity (ANSI/ESDA/JEDEC JS-001-2012) Class 3B Operating Case Temperature [1] -40°C to 135°C LED Storage Temperature -40°C to 135°C Soldering Temperature JEDEC 020c 260°C Allowable Reflow Cycles 3 Reverse Voltage [4] (Vreverse) LUXEON LEDs are not designed to be driven in reverse bias Notes for Table 4: 1. Proper current derating must be observed to maintain the junction temperature below the maximum allowable junction temperature. 2. Residual periodic variations due to power conversion from alternating current (AC) to direct current (DC), also called “ripple,” with frequencies ≥100Hz and amplitude ≤15% of the maximum allowable DC forward current are acceptable, assuming the average current throughout each cycle does not exceed the maximum allowable DC forward current at the corresponding maximum junction temperature. 3. Pulsed operation with a peak drive current equal to the stated peak pulsed forward current is acceptable if the pulse on-time is ≤5ms per cycle and the duty cycle is ≤50%. 4. Transient reverse voltages and surge currents due to electrical switching or supply interruptions are acceptable if these events do not last for more than 10ms, the amplitude of the reverse voltage does not exceed 5V and the reverse current is less than 220uA. 5. For torch application with portable battery source, maximum surge transient current during the initial turn-on is 3.5A for 180ms and thereafter not to exceed DC maximum rating current and LED junction temperature. Operating Conditions Figure 1 . Maximum permissible operating conditions for LUXEON HL2X . 100 105 110 115 120 125 130 135 140 00 .5 11 .5 22 .5 3 [ erutarepmeT jT xaM° C] Current [A] Tj
DS288 LUXEON HL2X Product Datasheet 20210523 ©2021 Lumileds Holding B.V. All rights reserved. 8 Product Bin and Labeling Definitions Decoding Product Bin Labeling In the manufacturing of semiconductor products, there are variations in performance around the average values given in the technical datasheet. For this reason, Lumileds bins LED components for luminous flux or radiometric power, color point, peak or dominant wavelength and forward voltage. LUXEON HL2X LEDs are labeled using a 4-digit alphanumeric CAT code following the format below: A B C D Where: A – designates luminous flux bin (example: V=290 to 300 lm, W=300 to 310 lm) B – designates color bin (example: 1=6500K, 2=5700K, 3=5000K, 4=3500K, 5=4000K, 7=3000K, 8=2700K) C – designates color space (example: 5/A/B/C/D=5-step MacAdam ellipse, 3=3-step MacAdam ellipse) D – designates forward voltage bin (example: X=2.65 to 2.85V, Y=2.85 to 3.00V) Therefore, a LUXEON HL2X 3000K 70CRI with a lumen range of 290 to 300 lm, color bin of 75 and a forward voltage range of 2.65 to 2.85V has the following CAT code: V 7 5 X
a particular bin varies by production run and by product performance. Not all bins are available in all CCTs. Table 5. Luminous flux bin definitions for LUXEON HL2X.
- Lumileds maintains a tolerance of ±6.5% on luminous flux measurements.
Table 9. Forward voltage bin definitions for LUXEON HL2X.
- Lumileds maintains a tolerance of ±0.1V on forward voltage measurements.
- Drawings are not to scale.
- All dimensions are in millimeters.
- Do not handle the device by the dome. Excessive force on the dome may damage the dome itself or the interior of the device.
Figure 10 . Mechanical dimensions for LUXEON HL2X .
Table 10. Reflow profile characteristics for LUXEON HL2X.
- All temperatures refer to the application Printed Circuit Board (PCB), measured on the surface adjacent to the package body.
Table 11 . Moisture sensitivity levels for LUXEON HL2X .
1 Unlimited ≤30°C / 85% RH 168 Hours +5 / -0 85°C / 85% RH
Figure 11. Visualization of the acceptable reflow temperature profile as specified in Table 10.
DS288 LUXEON HL2X Product Datasheet 20210523 ©2021 Lumileds Holding B.V. All rights reserved. 13 Solder Pad Design Notes for Figure 12: 1. Drawings are not to scale. 2. All dimensions are in millimeters. Figure 12 . Recommended PCB solder pad layout for LUXEON HL2X .
DS288 LUXEON HL2X Product Datasheet 20210523 ©2021 Lumileds Holding B.V. All rights reserved. 14 Packaging Information Pocket Tape Dimensions Notes for Figure 13: 1. Drawings are not to scale. 2. All dimensions are in millimeters. Figure 13 . Pocket tape dimensions for LUXEON HL2X . W F B B A A T Max5° B-B 3 : 1 Max5° A-A 3 : 1
DS288 LUXEON HL2X Product Datasheet 20210523 ©2021 Lumileds Holding B.V. All rights reserved. 15 Reel Dimensions Notes for Figure 14: 1. Drawings are not to scale. 2. All dimensions are in millimeters. 3. 1,000 pieces per reel. Figure 14 . Reel dimensions for LUXEON HL2X .
Product Datasheet 20210523 ©2021 Lumileds Holding B.V. All rights reserved. LUXEON is a registered trademark of the Lumileds Holding B.V. in the United States and other countries. lumileds.com Neither Lumileds Holding B.V. nor its affiliates shall be liable for any kind of loss of data or any other damages, direct, indirect or consequential, resulting from the use of the provided information and data. Although Lumileds Holding B.V. and/or its affiliates have attempted to provide the most accurate information and data, the materials and services information and data are provided “as is,” and neither Lumileds Holding B.V. nor its affiliates warrants or guarantees the contents and correctness of the provided information and data. Lumileds Holding B.V. and its affiliates reserve the right to make changes without notice. You as user agree to this disclaimer and user agreement with the download or use of the provided materials, information and data. A listing of Lumileds product/patent coverage may be accessed at lumileds.com/patents. About Lumileds Companies developing automotive, mobile, IoT and illumination lighting applications need a partner who can collaborate with them to push the boundaries of light. With over 100 years of inventions and industry firsts, Lumileds is a global lighting solutions company that helps customers around the world deliver differentiated solutions to gain and maintain a competitive edge. As the inventor of Xenon technology, a pioneer in halogen lighting and the leader in high performance LEDs, Lumileds builds innovation, quality and reliability into its technology, products and every customer engagement. Together with its customers, Lumileds is making the world better, safer, more beautiful—with light. To learn more about our lighting solutions, visit lumileds.com.