Objective Product Specification L1935 Low Noise Amplifier 1800-1950 MHz, 35 dB Gain, 0.9dB Noise Figure Page 1 of 2 January 2006 Document Revision Level B

FEATURES

  • Extremely low Noise Figure
  • High IIP3
  • Superior Return Loss
  • 35 dB Power Gain
  • Balanced Input Stage APPLICATION
  • Repeater
  • Base Station

DESCRIPTION

  • 1.9 GHz Low Noise Amplifier employing GaAs die LIMITING VALUES Notes: Operating the device above these parameters may cause permanent damage, Case Temperature Tc=25°C SYMBOL PARAMETER MIN. MAX. UNIT V1 - +12 V V2 DC supply voltage - -7 V Tstg Storage Temperature - 30 + 100 °C Topt Operating Temperature - 5 + 70 °C CHARACTERISTICS Table 1: Test condition: Case Temperature T c = 25°C, V1 = 10V, V2 = -5V SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT f Frequency 1800 - 1950 MHz I1 Supply Current - - 550 mA I2 Supply Current - - 20 mA Ga Power Gain - 35 - dB S11 Input Return Loss 20 - - dB S22 Output Return Loss 20 - - dB P1dB 1dB Compression Point 24 - - dBm IIP3 Input 3 rd Order Intercept Point 10 - - dBm NF Noise Figure - 0.9 - dB L1935 Low Noise Amplifier 1800-1950 MHz 35 dB Gain 0.9dB Noise Figure

Objective Product Specification L1935 Low Noise Amplifier 1800-1950 MHz, 35 dB Gain, 0.9dB Noise Figure Page 2 of 2 January 2006 Document Revision Level B DEFINITIONS Data Sheet Status Objective Product Specification This data sheet contains target or goal specifications for product development. Preliminary Product Specification This data sheet contains preliminary data; supplementary data may be published later. Product Specification This data sheet contains final product specifications. Limiting values Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 60134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability.

Application information

Where application information is given, it is advisory and does not form part of the specification. Premier Devices reserves the right to make changes without further notice to any products herein. Premier Devices makes no warranty representation or guarantee regarding the suitability of its products for any particular purpose, nor does Premier Devices assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including wit hout limitation consequential or incidental damages. “Typical” parameters which may be provided in Premier Devices datashee ts and/or specifications c an and do vary in different applications and actual performance may vary over time. A ll operating parameters, including “Typicals” must be validated for each customer application by customer´s technical exper ts. Premier Devices does not convey any license under its patent rights nor the rights of others. Premier Devices pr oducts are not designed, intended, or authorized for use as components in systems intended for surgical implant into t he body, or other applications intended to support or sustain life, or for any other application in which the failure of the Premier Devices product could create a situation where personal injury or death may occur. Should Buyer purchase or use Premier Devices products for any such unintended or unauthorized application, Buyer shall indemnify and hold Prem ier Devices and its officers , employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, and claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Premier Devices was negligent regarding the design or manufacture of the part. © Premier Devices Germany GmbH 2006 How to contact us: Premier Devices Germany GmbH Loeffelholzstrasse 20, D-90441 Nuernberg, Germany Phone: +49 (0) 911 9411 233, FAX: +49 (0) 911 9411 198, Email: sales.germany@premierdevices.com , Internet: http://www.premierdevices.de/