Features

  • Single chip 100BASE-TX/100BASE-FX/10BASE-T physical layer solution
  • 1.8V CMOS design, power consumption 250 mW
  • Robust (130m+) operation over standard cables
  • Supports Media Independent Interface (MII), Reduced MII (RMII), and Serial MII (SMII)
  • LinkMD feature to determine cable length and diagnose faulty cables up 200 m with +/- 2 m accuracy
  • Supports HP MDI/MDI-X auto crossover
  • Supports power down mode and power saving mode
  • MDC/MDIO to 12.5 MHz for rapid configuration
  • Fully compliant to IEEE 802.3u standard
  • Supports auto-negotiation and manual selection for 10/100Mbps speed and full / half-duplex mode Functional Diagram LED DRIVER LINK COL FDX SPD MII/RMII/SMII REGISTERS AND CONTROLLER INTERFACE TXD3 TXD2 TXC CRS COL RXD3 RXER RXDV RXC TXD1 TXD0 TXER TXEN MDIO MDC RXD2 RXD1 RXD0 4B/5B ENCODER SCRAMBLER PARALLEL/SERIAL PARALLEL/SERIAL MANCHESTER ENCODER 4B/5B DECODER DESCRAMBLER SERIAL/PARALLEL MANCHESTER DECODER SERIAL/PARALLEL NRZ /NRZI MLT3 ENCODER CLOCK RECOVERY AUTO NEGOTIATION POWER DOWN/ POWER SAVING PWRDWN PULSE SHAPER ADAPTIVE EQ BASELINE WANDER CORRECTION MLT3 DECODER NRZI /NRZ 10BASE-T RECEIVER TRANSMITTER TX+ TX- RX+ RX- PLL XI XO

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Features (continued)

  • Configurable through MII serial management ports or via external control pins
  • Programmable LED outputs for link, activity, full/half duplex, collision and speed
  • On-chip built-in analog front end filtering for both 100BASE-TX and 10BASE-T
  • Supports back to back, FX to TX for media converter

applications

  • Single 3.3V power supply with built-in 1.8V regulator (‘L’ parts)
  • 48 Pin LQFP, 48 Pin SSOP, 48 Pin QFN (targeted)

Ordering Information

Temp. Range Package Lead Finish KS8001L 0 o–70o C 48-LQFP Standard KSZ8001L 0 o–70o C 48-LQFP Lead-free KS8001LI - 40 o–85o C 48-LQFP Standard KS8001S 0 o–70o C 48-SSOP Standard KSZ8001S 0 o–70o C 48-SSOP Lead-free

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE.

Revision History

Revision Date Summary of Changes PRELIMINARY 25 Mar 2004 0.8 9 Aug 2004 • Updated pin 38 (VDDRCV) definition to 3.3V

  • Corrected pin configuration diagrams to reflect NC on pins 42 and 43
  • Updated crystal tolerance to +/- 50 ppm 0.81 17 Sep 2004 • Updated series resistance for crystal specification to 40 Ω 0.82 25 Jan 2005 • LinkMD distance coefficient changed to 0.39
  • Interrupt register status bits set to RO/SC
  • Recommended reset circuit added
  • RMII timing added 1.00 31 Mar 2005 • Added lead-free part numbers 1.01 16 May 2005 • Changed REXT value to 6.65 KΩ
  • Removed preliminary status
  • Added KS8001S to ordering information

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Table of Contents

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE.

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Pin Description Pin Number Pin Name Type (Note 1) Pin Function

1 MDIO I/O Management Interface (MII) Data I/O

This pin requires an external 10K pull-up resistor.

2 MDC I Management Interface (MII) Clock Input

This pin is synchronous to the MDIO data interface

3 RXD3/

Ipd/O MII Mode: Receive Data Output[3] 2 / Configuration Mode: The pull-up/pull-down value is latched as PHYADDR[1] during reset. See “Strapping Options” section for details.

4 RXD2/

MII Mode: MII Receive Data Output[2]2 / Configuration Mode: The pull-up/pull-down value is latched as PHYADDR[2] during reset. See “Strapping Options” section for details.

5 RXD1/

RXD[1]/ PHYAD3 Ipd/O MII Mode: Receive Data Output[1] 2 / RMII Mode: Receive Data Output[1]3 / Configuration Mode: The pull-up/pull-down value is latched as PHYADDR[3] during reset. See “Strapping Options” section for details.

6 RXD0/

RXD[0]/ RX PHYAD4 Ipd/O MII Mode: Receive Data Output[0] 2 / RMII Mode: Receive Data Output[0]3 / SMII Mode: Receive Data and Control4 / Configuration Mode: The pull-up/pull-down value is latched as PHYADDR[4] during reset. See “Strapping Options” section for details. 7 VDDIO Pwr Digital IO 2.5 /3.3V tolerance power supply.

8 GND Gnd Ground

9 RXDV/

PCS_LPBK Ipd/O MII Mode: Receive Data Valid Output / RMII Mode: Carrier Sense/Receive Data Valid / Configuration Mode: The pull-up/pull-down value is latched as pcs_lpbk during reset. See “Strapping Options” section for details.

10 RXC/

SMII_SELECT Ipd/O MII Receive Clock Output Operating at:

25 MHz = 100 Mbps

2.5 MHz = 10 Mbps

Configuration Mode: The pull-up/pull-down value is latched as SMII during reset. See “Strapping Options” section for details.

11 RXER/

RX_ER/ ISO Ipd/O MII Mode: Receive Error Output / RMII Mode: Receive Error / Configuration Mode: The pull-up/pull-down value is latched as ISOLATE during reset. See “Strapping Options” section for details.

12 GND Gnd Ground

13 VDDC Pwr Digital core 1.8 V only power supply

14 TXER Ipd MII Transmit Error Input

15 TXC/

I/O MII Mode: MII Transmit Clock Output / RMII Mode: 50 MHz Reference Clock Input / SMII Mode: 125 MHz Synchronization Clock Input

16 TXEN Ipd MII Transmit Enable Input

17 TXD0/

TXD[0]/ TX Ipd MII Mode: Transmit Data Input[0] / RMII Mode: Transmit Data Input[0] / SMII Mode: Transmit Data and Control

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Pin Number Pin Name Type (Note 1) Pin Function

18 TXD1/

TXD[1]/ SYNC Ipd MII Mode: Transmit Data Input[1] / RMII Mode: Transmit Data Input[1] / SMII Mode: SYNC

19 TXD2 Ipd MII Transmit Data Input[2]

20 TXD3 Ipd MII Transmit Data Input[3]

21 COL /

RMII_SELECT Ipd/O MII Collision Detect Output Configuration Mode: The pull-up/pull-down value is latched as RMII select during reset. See “Strapping Options” section for details.

22 CRS/

RMII_BTB Ipd/O MII Carrier Sense Output Configuration Mode: The pull-up/pull-down value is latched as RMII Loop- back during reset when RMII mode is selected. See “Strapping Options section” for details.

23 GND Gnd Ground

24 VDDIO Pwr Digital IO 2.5 / 3.3V tolerance power supply

25 INT#/

Ipu/O Management Interface (MII) Interrupt Out. Configuration Mode: Latched as PHYAD[0] during power up / reset. See “Strapping Options” section for details.

26 Programmable LED Output 0

Configuration Mode: The external pull down enable test mode and only used for tfactory test. Active Low. The LED0 pin is also programmable via register 1eh. LED mode = 00 Link/Act Pin State LED Definition No Link H Off Link L On LED0/ TEST Ipu/O Activity - Toggle LED mode = 01 Link Pin State LED Definition No Link H Off Link L On LED mode = 10 10Mbps Link Pin State LED Definition No Link H Off Link L On

27 Programmable LED Output 1

Configuration Mode: Latched as SPEED (Register 0, bit 13) during power up / reset. See “Strapping Options” Section for details. Active Low. The LED1 pin is also programmable via register 1eh. LED mode = 00 Speed Pin State LED Definition 10BT H Off LED1 / SPD100/ noFEF Ipu/O 100BT L On LED mode = 01 Speed Pin State LED Definition 10BT H Off 100BT L On

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Pin Number Pin Name Type (Note 1) Pin Function LED mode = 10 100Mbps Link Pin State LED Definition No Link H Off Link L On

28 Programmable LED Output 2

Configuration Mode: Latched as DUPLEX (register 0h, bit 8) during power up / reset. See “Strapping Options” Section for details. Active Low. The LED2 pin is also programmable via register 1eh. LED mode = 00 Duplex Pin State LED Definition Half H Off LED2/ DUPLEX Ipu/O Full L On LED mode = 01 Full Duplex/Col Pin State LED Definition Half H Off Full L On Collision - Toggle LED mode = 10 Duplex Pin State LED Definition Half H Off Full L On

29 Programmable LED Output 3

Configuration Mode: Latched as ANEG_EN (register 0h, bit 12) during power up / reset. See “Strapping Options” Section for details. Active Low. The LED3 pin is also programmable via register 1eh. LED mode = 00 Collision Pin State LED Definition No Collision H Off LED3/ NWAYEN Ipu/O Collision L On LED mode = 01 Activity Pin State LED Definition Activity - Toggle LED mode = 10 Activity Pin State LED Definition Activity - Toggle 30 PD# Ipu Power Down. 1=Normal operation, 0=Power down, Active low 31 VDDRX Pwr Analog 1.8 V power supply

32 RX- I Receive Input

Differential receive input pins for FX, 100BASE-TX or 10BASE-T

33 RX+ I Receive Input

Differential receive input pin for FX, 100BASE-TX or 10BASE-T

34 FXSD/

Ipd/O Fiber Mode Enable / Signal Detect in Fiber Mode If FXEN=0, FX mode is disable. The default is “0”. See “100BT FX Mode” section for more details.

35 GND Gnd Ground

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Pin Number Pin Name Type (Note 1) Pin Function

36 GND Gnd Ground

37 REXT I External resistor (6.65K Ω) connects to REXT and GNDRX 38 VDDRCV Pwr Analog 3.3 V power supply (See “Circuit design ref for power supply” section for details)

39 GND Gnd Ground

40 TX- O Transmit Outputs

Differential transmit output for 100BASE-TX/FX or 10BASE-T

41 TX+ O Transmit Outputs

Differential transmit output for FX, 100BASE-TX/FX or 10BASE-T

42 NC No Connect

43 NC No Connect

44 GND Gnd Ground

45 XO O XTAL feedback

Used with XI for Xtal application.

46 XI I Crystal Oscillator Input

Input for a crystal or an external 25 MHz clock 47 VDDPLL Pwr Analog PLL 1.8 V power supply

48 RST# Ipu Chip Reset

Active low, minimum of 50 us pulse is required Note 1: Pwr = power supply; Gnd = ground; I = input; O = output; I/O = bi-directional Ipu = input w/ internal pull up; Ipd = input w/ internal pull down; Ipu/O = input w/ internal pull up during reset, output pin otherwise; Ipd/O = input w/ internal pull down during reset, output pin otherwise; PD = strap pull down; PU = strap pull up; Note 2: presents valid data to MAC through the MII. RXD [3..0] is invalid when RXDV is de-asserted. Note 3: RMII Rx Mode: The RXD[1..0] bits are synchronous with REF_CLK. For each clock period in which CRS_DV is asserted, two bits of recovered data are sent from the PHY. Note 4: SMII Rx Mode: Receive data and control information are sent in 10 bit segments. In 100MBit mode, each segment represents a new byte of data. In 10MBit mode, each segment is repeated ten times; therefore, every ten segments represents a new byte of data. The MAC can sample any one of every 10 segments in 10MBit mode. Note 5: presents valid data from the MAC through the MII. TXD [3..0] has no effect when TXEN is de-asserted. Note 6: RMII Tx Mode: The TXD[1..0] bits are synchronous with REF_CLK. For each clock period in which TX_EN is asserted, two bits of recovered data are recovered by the PHY. Note 7: SMII Tx Mode: Transmit data and control information are received in 10 bit segments. In 100MBit mode, each segment represents a new byte of data. In 10MBit mode, each segment is repeated ten times; therefore, every ten segments represents a new byte of data. The PHY can sample any one of every 10 segments in 10MBit mode.

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Strapping Options Pin Number Pin Name Type (Note 2) Description 6,5, 4,3 PHYAD[4:1] / RXD[0:3] Ipd/O

25 PHYAD0/

INT# Ipu/O PHY Address latched at power-up / reset. The default PHY address is 00001.

9 PCS_LPBK/

Ipd/O Enables PCS_LPBK mode at power-up / reset. PD (default) = Disable, PU = Enable

10 SMII_SELECT

/ RXC Ipd/O Enables SMII mode at power-up / reset. PD (default) = Disable, PU = Enable 11 ISO / RXER Ipd/O Enables ISOLATE mode at power-up /reset. PD (default) = Disable, PU = Enable

21 RMII_SELECT

/ COL Ipd/O Enables RMII mode at power-up / reset. PD (default) = Disable, PU = Enable

22 RMII_BTB/

Ipd/O Enable RMII_BTB mode at power-up / reset. PD (default) = Disable, PU = Enable

27 SPD100 /

Ipu/O Latched into Register 0h bit 13 during power-up / reset. PD = 10Mb/s, PU (default) = 100Mb/s. If SPD100 is asserted during power-up / reset, this pin also latched as the Speed Support in register 4h. (If FXEN is pulled up, the latched value 0 means no Far _End _Fault.)

28 DUPLEX/

Ipu/O Latched into Register 0h bit 8 during power-up / reset. PD = Half Duplex, PU (default) = Full duplex. If Duplex is pulled up during reset, this pin also latched as the Duplex support in register 4h.

29 NWAYEN/

Ipu/O Nway (auto-=Negotiation) Enable Latched into Register 0h bit 12 during power-up / reset. PD = Disable Auto-Negotiation, PU (default) = Enable Auto- Negotiation

30 PD# Ipu Power Down Enable

PU (default) = Normal operation, PD = Power down mode Note: Strap-in is latched during power up or reset. In some syst ems, the MAC RXD pins may driv e high at all times causing the PHY strap-in to be latched high during power up or system reset. In this case, it is recommended to use a strong pull down to GND via 1kohm resistor on RXDV, RXC, and RXER pins. Otherwise, the PHY may stay in Isolate or loop back modes.

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Pin Configuration KS8001S XO GND NC RST# NC TX- GND VDDPLL XI TX+ VDDRCV REXT MDIO MDC RXD3/PHYAD1 RXD2/PHYAD2 RXD0/PHYAD4 VDDIO RXC RXER/ISO RXD1/PHYAD3 GND RXDV/PCS_LPBK GND VDDC TXER TXC/REF_CLK TXEN TXD0 TXD1 TXD2 TXD3 COL/RMII CRS/RMII_BTB GND VDDIO GND GND FXSD/FXEN RX+ RX- VDDRX PD# LED3/NWAYEN LED2/DUPLEX LED1/SPD100 LED0/TEST INT#/PHYAD0 Top View SSOP 48 KS8001L RX+ RX- VDDRX GND PD# LED2/DUPLEX LED1/SPD100 GND FXSD/FXEN LED3/NWAYEN LED0/TEST INT#/PHYAD0 VDDC TXER TXC/REF_CLK TXEN TXD0 TXD1 TXD2 TXD3 COL/RMII CRS/RMII_BTB GND VDDIO MDIO MDC RXD3/PHYAD1 RXD2/PHYAD2 RXD0/PHYAD4 VDDIO RXC RXER/ISO RXD1/PHYAD3 GND RXDV/PCS_LPBK GND RST# VDDPLL XI XO NC TX- GND VDDRCV REXT GND NC TX+ Top View LQFP 48

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Functional Description 100BASE-TX Transmit The 100BASE-TX transmit function performs parallel-to-seria l conversion, NRZ to NRZI c onversion, MLT- 3 encoding and transmission. The circuitry starts with a parallel-to-serial c onversion, which converts the 25 MHz, 4-bit nibbles into a 125 M Hz serial bit stream. The incoming data is clocked in at the positive edge of the TXC signal. The serializ ed data is further converted from NRZ to NRZI format, and then transmitted in MLT3 current outpu t. The output current is set by an external 1% 6.65 K Ω resistor for the 1:1 transformer ratio. It has typical rise/fall times of 4 ns and complies with the ANSI TP -PMD standard regarding amplitu de balance, overshoot and timing jitter. The wave-shaped 10BASE-T output driver is also incorporated into the 100BASE-TX driver. 100BASE-TX Receive The 100BASE-TX receive function performs adapt ive equalization, DC restoration, ML T-3 to NRZI conversion, data and clock recovery, NRZI to NRZ conversion, and serial-to-parallel conversion . The receiving side starts with the equalization filter to compensate for inter-symbol interference (ISI) over the twist ed pair cable. Since the amplit ude loss and phase distortion are a function of the length of the c able, the equalizer has to adjust it s characteristic to optimize per formance. In this design, t he variable equalizer will make an initial estimation based upon comparis ons of incoming signal strength against some known cable characteristics, then tunes itself for optimization. This is an ongoing process and can self adjust against environmental chan ges such as temperature variations. The equalized signal then goes through a DC restoration and data conversion block. The DC restoration circuit is used to compensate for the effects of base line wander and to improve t he dynamic range. The differential data conversion circuit conv erts the MLT3 format back to NRZI. The slicing threshold is also adaptive. The clock recovery circuit extracts the 125 MHz clock from the edges of the NRZI signal. This recovered clock is then used to convert the NRZI signal into the NRZ format. Finally, the NRZ se rial data is converted to 4-bit parallel 4B nibbles. A synchr onized 25 MHz RXC is generated so that the 4B nibbles is clocked out at the negat ive edge of RCK25 and is valid for the receiver at th e positive edge. When no valid data is present, the clock recovery circuit is locked to the 25 M Ηz reference clock and both TXC and RXC clocks continue to run. PLL Clock Synthesizer The KS8001 generates 125 M Ηz, 25 M Ηz and 20 M Ηz clocks for system timing. An internal crystal oscill ator circuit provides the reference clock for the synthesizer. Scrambler/De-scrambler (100BASE-TX only) The purpose of the scrambler is to spread the power spectrum of the signal in order to reduce EMI and baseline wander. 10BASE-T Transmit When TXEN (transmit enable) goes high, data encoding and tran smission will begin. The KS8001 will continue to encode and transmit data as long as TXEN remains high. The data transmission will end when TXEN goes low. The last transition occurs at the boundary of the bit cell if the last bit is zero, or at the center of t he bit cell if the last bit is one. The output driver i s incorporated into the 100BASE- driver to allow transmission with the same magn etics. They are internally wave-shaped and pre-emphasized into outputs with a typical 2.5 V amplitude. T he harmonic contents are at least 27 dB below the fundamental when driven by an all-o nes Manchester-encoded signal. 10BASE-T Receive On the receive side, input buffer and level detecting squelch circ uits are employed. A differential input receiver circuit and a PLL performs the decoding function. The Manches ter-encoded data stream is separated into clock signal and NRZ data. A squelch circuit rejects signals with levels less than 300 mV or with shor t pulse widths in order to prevent noises at the RX+ or RX- in put from falsely trigger the decoder. When the input exceeds the sque lch limit, the PLL locks onto the incoming signal and the KS8001 decodes a data frame. This activates the carrier sense (CRS) ad RXDV signals and makes the receive data (RXD) available. The receive clock is maintained active during idle periods in between data reception.

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. SQE and Jabber Function (10BASE-T only) In 10BASE-T operation, a short pulse will be put out on the COL pin after each packet is transmitted. This is required as a test of the 10BASE-T transmit/receive path and is called SQE test. The 10BASE- T transmitter will be disabled and COL will go high if TXEN is High for more than 20 ms (Jabbering). If TXEN then goes low for more than 250 ms, the 10BASE-T transmitter will be re-enabled and COL will go Low. Auto-Negotiation The KS8001 performs auto-negotiation by har dware strapping option (pin 29) or softwar e (Register 0.12). It will automatically choose its mode of operation by advertising its abilities and comparing them with those received from its link partner whenever auto- negotiation is enabled. It can also be configured to advertise 100BASE-TX or 10BASE-T in either full- or half-duplex mode. Au to- negotiation is disabled in FX mode. During auto-negotiation, the contents of Regist er 4, coded in Fast Link Pulse (FLP), will be sent to its link partner under the conditions of power-on, link-loss or re-start. At the same time, the KS8001 will monitor incoming data to determine its mode o f operation. Parallel detection circuit will be enabled as soon as either 10BASE-T NLP (Normal Link Pulse) or 100BASE-TX idle is detected. The operation mode is configured based on the following priority:

  • Priority 1: 100BASE-TX, full-duplex
  • Priority 2: 100BASE-TX, half-duplex
  • Priority 3: 10BASE-T, full-duplex
  • Priority 4: 10BASE-T, half-duplex When the KS8001 receives a burst of FLP from its link partner with 3 identical link code words (ignoring acknowledge bit), it will store these code words in Register 5 and wait for the next 3 identical code words. Once the KS8001 detects the second code words, it then configures itself accordi ng to the above-mentioned priority. In addition, the KS8001 also checks for 100BASE-TX idle or 10BASE-T NLP symbols. If either is detected, the KS8001 automatically configures to match the detected operating speed. MII Management Interface The KS8001 supports the IEEE 802.3 MII Mana gement Interface, also known as the Management Data Input / Output (MDIO) Interface. This interface allows upper-layer devices to monito r and control the state of the KS8001. The MDIO interface consi sts of the following:
  • A physical connection including a data line (MDIO), a clock line (MDC) and an optional interrupt line (INTRPT)
  • A specific protocol that runs across the above-mentioned phy sical connection and it also allows one controller to communicate with multiple KS8001 devices. Each KS8001 is assigned an MII address between 0 and 31 by the PHYAD inputs.
  • An internal addressable set of fourteen 16-bit MDIO registers. Register [0:6] are required and their functions are specified by the IEEE 802.3 specifications. Additional registers are provided for expanded functionality. The INTPRT pin functions as a management data interrupt in the MII. An active Low or High in this pin indicates a status change on the KS8001 based upon 1fh.9 level c ontrol. Register bits at 1bh[15:8] are the in terrupt enable bits. Register bits at 1bh[7:0] are the interrupt condition bits. This interrupt is cleared by reading Register 1bh. MII Data Interface The data interface consists of separate channels for transmitting data from a 10/100 802.3 compliant Media Access Controller (MAC) to the KS8001, and for receiving data from the line. Normal data transmission is implemented in 4B Nibble Mode (4-bit wide nibbles). Transmit Clock (TXC) : The transmit clock is normally generated by the KS 8001 from an external 25MHz reference source at the X1 input. The transmit data and control signals must always be synchronized to the TXC by the MAC. The KS8001 normally samples these signals on the rising edge of the TXC.

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Receive Clock (RXC): For 100BASE-TX links, the receive clock is continuously recovered from the line. If the link goes down, and auto-negotiation is disabled, the receive clock then operates off the master input clock (X1 or TXC). For 10BASE-T links, the receive clock is recovered from the line while carrier is active, and oper ates from the master input clock when the line is idle. The KS8001 synchronizes the receive data and control signals on the falling e dge of RXC in order to stabilize the signals at the rising edge of the clock with 10ns setup and hold times. Transmit Enable: The MAC must assert TXEN at the same time as the fi rst nibble of the preamble, and de-assert TXEN after the last bit of the packet. Receive Data Valid: The KS8001 asserts RXDV when it receives a valid packet. Line operating speed and MII mode will determine timing changes in the following way:

  • For 100BASE-TX link with the MII in 4B mode, RXDV is asserted fr om the first nibble of the pream ble to the last nibble of the data packet.
  • For 10BASE-T links, the entire preamble is tr uncated. RXDV is asserted with the first nibble of the SFD “ 5D” and remains asserted until the end of the packet. Error Signals: Whenever the KS8001 receives an error symbol from the network, it asserts RXER and drives “1110” (4B) on the RXD pins. When the MAC asserts TXER, the KS8001 will drive “H” symbols (a Transmit Error define in the IEEE 802.3 4B/5B code group) out on the line to force signaling errors. Carrier Sense (CRS) : For 100TX links, a start-of-stream delimiter, or /J/K sy mbol pair causes assertion of Carrier Sense (CRS). An end-of-stream delimiter,or /T/R symbol pair causes de-assertion of CRS. The PMA layer will also de-assert CRS if IDLE symbols are received without /T/R, yet in this case RXER will be asse rted for one clock cycle when CRS is de-asserted. For 10T links, CRS assertion is based on reception of valid preamble, and de-assertion on reception of an end-of-frame (EOF) marker. Collision: Whenever the line state is half-duplex and the transmitter and receiver are ac tive at the same time, then the KS8001 asserts its collision signal, which is asynchronous to any clock. RMII (Reduced MII) Data Interface RMII interface specifies a low pin count (Reduced) Media Independent Interface (RMII) intended for use between Ethernet PHYs and Switch or Repeater ASICs. It is fully compliant with IEEE 802.3u [2]. This interface has the following characteristics:
  • It is capable of supporting 10Mb/s and 100Mb/s data rates
  • A single clock reference is sourced from the MAC to PHY (or from an external source)
  • It provides independent 2 bit wide (di-bit) transmit and receive data paths
  • It uses TTL signal levels, compatible with common digital CMOS ASIC processes RMII Signal Definition Signal Name Direction (with respect to the PHY) Direction (with respect to the MAC) Use REF_CLK Input Input or Output Synchronous clock reference for receive, transmit and control interface CRS_DV Output Input Carrier Sense/Receive Data Valid RXD[1:0] Output I nput Receive Data TX_EN Input Output Transit Enable TXD[1:0] Input Out put Transit Data RX_ER Output Input (Not Required) Receive Error Note: Unused MII signals, TXD[3:2], TXER need to be tied to GND when RMII is used

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Reference Clock (REF_CLK) REF_CLK is a continuous 50 MHz clock that provides the timi ng reference for CRS_DV, RXD[1:0], TX_EN, TXD[1:0], and RX_ER. REF_CLK is sourced by the MAC or an external source. Switch im plementations may choose to provide REF_CLK as an input or an output depending on whether they provide a REF_CLK output or rely on an external clock distribution device. Each PHY device shall have an input corresponding to this clock but may use a single clock input for multiple PHYs implemented on a single IC. Carrier Sense/Receive Data Valid (CRS_DV) CRS_DV is asserted asynchronously on detection of carrier due to t he criteria relevant to the oper ating mode. That is, in 10BAS E-T mode, when squelch is passed or in 100BASE- X mode when 2 non-contiguous zeroes in 10 bits are detected carrier is said to be detected. Loss of carrier shall result in the de-asse rtion of CRS_DV synchronous to REF_CLK. So long as carrier criteria are being met, CRS_DV shall remain asserted continuously from the first recovered di-bit of the frame through the final recovered di-bit and shall be negated prior to the first REF_CLK that follows the final di-bit. The data on RXD[1:0] is considered valid once CRS_DV is assert ed. However, since the assertion of CRS_DV is asynchronous relative to REF_CLK, the data on RXD[1:0] shall be "00" until proper receive signal decoding takes place (see definition of RXD [1:0] behavior). Receive Data [1:0] (RXD[1:0]) RXD[1:0] shall transition synchron ously to REF_CLK. For each clock period in whic h CRS_DV is asserted, RXD[1:0] transfers two bits of recovered data from the PHY. In some cases (e.g. before data recovery or during error conditions) a pre-determined valu e for RXD[1:0] is transferred instead of recovered data. RXD[1:0] shall be "00" to indi cate idle when CRS_DV is de-asserted. Values o f RXD[1:0] other than "00" when CRS_DV is de-asserted are reserved for out-of-band signaling (to be defined). Values other than "00" on RXD[1:0] while CRS_DV is de-asserted shall be ignored by the MAC/repeater. Upon assertion of CRS_DV, the PHY shall ensure that RXD[1:0]=00 until proper receive decoding takes place. Transmit Enable (TX_EN) Transmit Enable TX_EN indicates that the MAC is presenting di-b its on TXD[1:0] on the RMII for trans-mission. TX_EN shall be asserted synchronously with the first nibbl e of the preamble and shall remain assert ed while all di-bits to be transmitted are presented to the RMII. TX_EN shall be negated prior to the first REF_CLK following the final di-bit of a frame. TX_EN shall transition synchronously with respect to REF_CLK. Transmit Data [1:0] (TXD[1:0]) Transmit Data TXD[1:0] shall transition sync hronously with respect to REF_CLK. When TX_EN is asserted, TXD[1:0] are accepted for transmission by the PHY. TXD[1:0] shall be "00" to indicate idle when TX_EN is de -asserted. Values of TXD[1:0] other than "00" when TX_EN is de-asserted are reserved for out-of-band signaling (t o be defined). Values other than "00" on TXD[1:0] while TX_E N is disserted shall be ignored by the PHY. Collision Detection Since the definition of CRS_DV and TX_EN bot h contain an accurate indication of t he start of frame, the MAC can reliably regenerate the COL signal of the MII by Ending TX_EN and CRS_DV. During the IPG time following the successful transmission of a frame, the COL signal is asserted by some transceivers as a self-test. The Signal Quality Error (SQE) function will not be supported by the reduced MII due to the lack of the COL signal. Historicall y, SQE was present to indicate that a transceiver located physically remote from the MAC was functioning. Since the reduced MII only supports chip-to-chip connections on a PCB, SQE functionality is not required. RX_ER The PHY shall provide RX_ER as an output a ccording to the rules specified in IEEE 8 02.3u [2] (see Clause 24, Figure 24-11 - Receive State Diagram). RX_ER shall be asserted for one or more RE F_CLK periods to indicate that an error (e.g. a coding error or any error that a PHY is capable of det ecting, and that may otherwi se be undetectable by the MAC sublayer) was detected somewhere in the frame presently being tran sferred from the PHY. RX_ER shall transition synchronously with respect to REF_CLK. While CRS_DV is de-asserted, RX_ER shall have no effect on the MAC.

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. RMII AC Characteristics RMII Transmit Timing REF_CLK 20ns TXD[1:0] TXEN TXER Parameter Min Typ Max Units REF_CLK Frequency 50 MHz TXEN, TXD[1:0], TX_EN, Data Setup to REF_CLK rising edge 4 ns TXEN, TXD[1:0], TX_EN, Data hold from REF_CLK rising edge 2 ns RMII Receive Timing REF_CLK 20ns tod RXD[1:0] RXDV RXER Parameter Min Typ Max Units REF_CLK Frequency 50 MHz RXD[1:0], CRS_DV, RX_ER Output delay from REF_CLK rising edge 2.8 10 ns

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. SMII Signal Definition SMII is composed of two signals per port, a global synchronizati on signal, and a global 125MHz reference clock. All signals are synchronous to the clock. All SMII I/F uses a common 125MHz reference clock and SYNC signals that are synchronous to the reference clock. There are two signals in SMII from MAC-to -PHY for each port (TXD and TxSYNC), and one signal per port from PHY-to-MAC (RXD). The Serial Media Independent Interface (SMII) is designed to satisfy the following requirements:

  • Convey complete MII information between a 10/100 PHY and MAC with two pins per port.
  • Allow a multi-port MAC/PHY communication with one system clock.
  • Operate in both half and full duplex.
  • Per packet switching between 10Mbit and 100Mbit data rates.
  • Allow direct MAC to MAC communication. SMII Signals Signal Name From To Use RX PHY MAC Receive Data and Control TX MAC PHY Transmit Data and Control SYNC MAC PHY Synchronization Clock System MAC&PHY Synchronization Receive Path Receive data and control information are signaled in ten bit segm ents. In 100Mbit mode, each segm ent represents a new byte of data. In 10Mbit mode, each segmen t is repeated ten times; therefor e, every ten segments represent a new byte of data. The MAC can simply any one of every 10 segment ion 10Mbit mode. Segment boundaries are delimited by SYNC. The MAC continuously generates a pulse on SYNC every 10 clocks. Receive Sequence Diagram CRS RX_DV RXD0 RXD1 RXD2 RXD3 RXD4 RXD5 RXD6 RXD7 RX_CLK RX_SYNC RX RX contains all of the information found on the receive path of the standard MII. Bits Purpose CRS Carrier Sense – identical to MII, except that it is not an asynchronous signal RX_DV Receive Data Valid – identical to MII RXD7-0 Encoded Data, see the RXD0-7 Encoding table RX – Bit Description RXD7-0 are used to convey packet data, RX_ER, and PHY status. The MAC can infer the meaning of RXD on a segment-by-basis by encoding the two control bits.

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. CRS RX_DV RXD0 RXD1 RXD2 RXD3 RXD4 RXD5 RXD6 RXD7 X 0 RX_ER from previous frame Speed 0=10Mbit 1=100Mbit Duplex 0=Half 1=Full Link 0=Down 1=Up Jabber 0=OK 1=Error Upper Nibble 0=invalid 1=valid False Carrier Detected X 1 One Data Byte (Two MII Data Nibble) TXD7 – 0 Encoding Inter-frame status bit RXD5 conveys the validity of the upper nibble of the byte of the previous frame. Inter-frame status bit RXD0 indicates whether or not the PHY detected an error somewhere on the previous frame. Both of these bits should be valid in the segment immediately following a frame, and should stay valid until the first data segment of the next frame begins. When asserted, inter-frame status bit RXD6 indicates that the PHY has detected a false carrier event. In order to send receive data to the MAC synchronous to the reference clock, the PHY must pass the data through an elasticity FIFO to handle any difference between the reference clock rate and the clock at the packet source. The Ethernet specification calls for packet data to be referenced to a clock with a frequency tolerance of 100ppm (0.01%); however, it is not uncommon to encounter Ethernet stations with clocks that have frequency errors up to 0.1%. Therefore, the elasticity FIFO should be at least 27 bits * long, filling to the half-way point before beginning valid data transfer via RX. RX_ER should be asserted if, during the reception of a frame, this fifo overflows or underflows. Only RXD and RX_DV should be passed through the elasticity FIFO. CRS should not be passed through the elasticity FIFO. Instead, CRS should be asserted for the time the ‘wire’ is busy receiving a frame. Transmit Path Transmit data and control information are signaled in ten bit segments, just like the receive path. In 100Mbit mode, each segment represents anew byte of data. In 10Mbit mode each segment is repeated ten times; therefore, every ten segments represents a new byte of data. The PHY can sample any one of every 10 segments in 10Mbit mode. Segment boundaries are delimited by SYNC. The MAC continuously generates a pulse on SYNC every 10 clocks. Transmit Sequence Diagram TX_ER TX_EN TXD0 TXD1 TXD2 TXD3 TXD4 TXD5 TXD6 TXD7 TX_CLK TX_SYNC TX Bits Purpose TX_EN Transmit Enable – identical to MII TX_ER Transmit Error – identical to MII TXD7-0 Encoded Data – see TXD7-0 Encoding Table TX- Bit Description

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. As far as the PHY is concerned, TXD7-0 are used to convey only packet data. To allow for a direct MAC to MAC connection, the MAC uses TXD7-0 to signal ‘status’ in between frames. TX_ER TX_EN TXD0 TXD1 TXD2 TXD3 TXD4 TXD7-5 x 0 Use to force an error in a direct MAC to MAC connection 100MBit Full Duplex Link Up No Jabber x 1 One Data Byte (Two MII Data Nibbles) TXD7 – 0 Encoding Collision Detection Collisions occur when CRS and TX_EN are simultaneously asserted. For this to work, the PHY must ensure that CRS is not affected by its transmit path. DC Specification Parameter Symbol Min Max Units Input High Voltage Vih 2.0 Volts Input Low Voltage Vil 0.8 Volts Input High Current Iih -10 10 uA Input Low Current Iil -10 10 uA

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Timing Specification Parameter Min Max Units Input Setup 1.5 ns Input Hold 1 ns Output Delay 1.5 5 ns

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. HP Auto Crossover (Auto MDI/MDI-X) Automatic MDI/MDI-X configuration is intended to eliminate t he need for crossover cables between similar devices. The assignmen t of pin-outs for a 10/100 BASE-T crossover function cable is shown below. This feature can eliminate the c onfusion in real applications by allowing both straight cable and crossove r cables. This featu re is controlled by register 1f:13, see “Register 1fh” section for details. R e c e ive P a irTransm i t Pai r R e c e ive P a ir Transm i t Pai r Strai ght Through Cabl e 10/100 Base-T Medi a Dependent Interface 10/100 Base-T Medi a Dependent Interface Modul ar Connector (RJ45) NI C Modul ar Connector (RJ45) HUB (Repeater or Swi tch) R ece ive P a ir R e ceive P air T ra nsm it P a ir T ra nsm it P a ir Crossover Cable 10/ 100 BASE-T Media Dependent Interface 10/100 Base-T Media Dependent Interface Modul ar Connector (RJ45) HUB (Repeater or Swi tch) Modular Connector (RJ45) HUB (R epeater or Switch)

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Auto MDI/MDI-X Cross-Over Transformer Connection KS8001 features HP Auto MDI/MDI-X crosso ver and requires symmetric transformers t hat support Auto MDI/MDI-X. See Selection of Isolation Transformers on p. 43 for a list of transformers that support Auto MDI/MDI-X. Power Management The KS8001 offers the following modes for power management:

  • Power Down Mode: This mode can be achieved by writing to Register 0.11 or pulling pin 30 PD# Low. In the power down state, the KS8061 disables all internal func tions and drives output pins to logic zero , except for the MII serial management interface.
  • Power Saving Mode: writing to register 1fh.10 can disable this mode . The KS8001 will then turn off everything except for the Energy Detect and PLL circuits when the cable is not installed. In other word s, the KS8001 will shutdown most of the internal circuits to save power if there is no link. Powe r Saving mode will be in this most effective state when Auto- Negotiation Mode is enabled. 100BT FX Mode 100BT FX mode is activated when FXSD/FXEN is higher than 0.6V (This pin has a default pull down). Under this mode, the auto- negotiation and auto-MDIX features are disabled. In fiber operation FXSD pin should connect to the SD (signal detect) output of the fiber module. The internal threshold of FXSD is around ⅔ Vdd +/- 50 mV (2.2V +/- 0.05V at 3.3V). Above this level, it is considered Fiber signal detected, and the operation is summarized in the following table: FXSD/FXEN Condition Less than 0.6V 100TX mode Less than 2.15V, but greater than 0.6V FX mode No signal detected FEF generated Greater than 2.25V FX mode Signal detected To ensure proper operation, the swing of fiber module SD should cover the th reshold variation. A resistive voltage divider is recommended to adjust the SD voltage range. FEF (Far End Fault), repetition of a special pattern, which c onsists of 84-ones and 1-zero, is generated under “FX mode with no signal detected”. The purpose of FEF is to notify the sender of a faulty link. When receiving a FEF, the LINK will go down to indicate a fault, even with fiber signal detected. The transmitter is not affected by receiving a FEF and still sends out its normal tra nsmit pattern from MAC. FEF can be disabled by strapping pin27 low, please refer to “Strapping Options” section. Media converter operation The KS8001 is capable of performing media conver sion with 2 parts in a back-to-back RMII mode as indicated in the diagram. Both parts are in RMII mode and with RMII_BTB asserted (pin21 & 22 strapped high). One part is operatin g at TX mode and the other in FX mode. Both parts can share a common 50MHz oscillator. Under this operation, auto-Negotiation on the TX side will proh ibit 10BASE-T link up. Additional options can be implemented und er this operation. Disable the transmitter and set it at tri-state by controlling the high TXD2 pin. In order to do this, RXD2 and TXD2 pins need to be connected via an inverter. When TXD2 pin is high in both the copper and fiber operation, it disables transmit. Meanwhile, the RXD2 pin on the copper side serves as the energy detect and can indicate if a li ne signal is detected. TXD3 should be tied low and RXD3 let float. Please contact your local Micrel FAE for a Media Converter reference design.

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. KS8001 Rx +/- Tx +/- FTx FRx KS8001 Vcc Pin RxD TxD To the SD pin of the Fiber Module (Fiber Mode) Vcc RxD TxD 21 22 Pin Pin 21 22 OSC

50 MHz

Ref_CLK TxC/ Ref_CLK LinkMD Cable Diagnostics The KS8001 utilizes time domain reflectometry (TDR) to analyze the cabling plant for common cabling problems such as open circuits, short circuits and impedance mismatches. LinkMD wo rks by sending a pulse of known amplitude and duration down the MDI and MDIX pairs and analyzing the shape of the reflected signal. Timing the durat ion gives an indication of the distance to the cabling fault with maximum distance of 200 m and accuracy of +/- 2 m. Cable diagnostics are only valid for copper connections and do not support fiber optic operation. LinkMD is used by accessing register 1dh, the LinkMD Control/Status register in conjunction with register 1fh, the 100BASE-TX PHY Controller register. To use LinkMD, HP Auto -MDIX is disabled by writing a ‘1’ to 1f:13 to enable manual control over which pai r is used to transmit the LinkMD pulse. The self-clearing Cable dia gnostic test enable bit, 1d.15 is set to ‘1’ to start the test on this pair. cable diagnostic test results are as follows:

  • 00 = Valid test, normal condition
  • 01 = Valid test, open circuit in cable
  • 10 = Valid test, short circuit in cable
  • 11 = Invalid test, LinkMD failed The ‘11’ case, Invalid test, occurs when it is not possible for the KS8001 to shut down the link partner. In this case, the te st is not run, since it would not be possible for t he KS8001 to determine if the detected signal is a reflection of the signal generated or a signal from another source. Cable length can be determined by multiplyi ng the contents of 1d.8:0 by 0.39. This constant may be calibrated for different ca bling conditions, including cables with a velocity of propagation that varies significantly from the norm.

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Reference Clock Connection Options KS8001 is capable of performing three different kinds of clock speed options for connecting the external reference clock depend s upon the different inte rface of using MII/RMII/SMII. The fi gures below illustrate the recomm ended connection for using the diff erent interface options. Please see the selection of reference crystal table for specifications. XI XO 25MHz Osc 100ppm NC NC 25MHz Oscillator Reference Clock Connection Diagram XI XO 22pF 22pF 22pF 22pF 25MHz Xtal 100ppm 25MHz Crystal Reference Clock Connection Diagram 50/125MHz Osc 100ppm NC NC 10K XI XO REF_CLK VCC 50/125MHz Oscillator Reference Clock Connection for RMII/SMII Mode Diagram

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Register Map Register No. Description 0h Basic Control Register 1h Basic Status Register 2h PHY Identifier I 3h PHY Identifier II 4h Auto-Negotiation Advertisement Register 5h Auto-Negotiation Link Partner Ability Register 6h Auto-Negotiation Expansion Register 7h Auto-Negotiation Next Page Register 8h Link Partner Next Page Ability 9h-14h Reserved 15h RXER Counter Register 16h – 1ah Reserved 1bh Interrupt Control/Status Register 1ch Reserved 1dh LinkMD Control/Status Register 1eh PHY Control Register 1fh 100BASE-TX PHY C ontrol Register Address Name Description Mode Default Register 0h – Basic Control 0.15 Reset 1 = software reset. Bit is self-clearing RW/ SC

0.14 Loop-back 1 = loop-back mode

0 = normal operation RW 0

0.13 Speed Select

(LSB) 1 = 100Mb/s 0 = 10Mb/s Ignored if Auto-Negotiation is enabled (0.12 = 1) RW Set by SPD100

0.12 Auto-

1 = enable auto-negotiation process (override 0.13 and 0.8) 0 = disable auto-negotiation process RW Set by NWAYEN

0.11 Power Down 1 = power down mode

0 = normal operation RW 0

0.10 Isolate 1 = electrical isolation of PHY from MII and

0 = normal operation RW Set by ISO

0.9 Restart Auto-

1 = restart auto-negotiation process 0 = normal operation. Bit is self-clearing RW/ SC

0.8 Duplex Mode 1 = full duplex

0 = half duplex RW Set by DUPLEX

0.7 Collision Test 1 = enable COL test

0 = disable COL test RW 0 0.6:1 Reserved RO 0

0.0 Disable

0 = enable transmitter 1 = disable transmitter R/W 0

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Address Name Description Mode Default Register 1h – Basic Status 1.15 100BASE-T4 1 = T4 capable 0 = not T4 capable RO 0 1.14 100BASE-TX Full Duplex 1 = capable of 100BASE-X full duplex 0 = not capable of 100BASE-X full duplex RO 1 1.13 100BASE-TX Half Duplex 1 = capable of 100BASE-X half duplex 0 = not capable of 100BASE-X half duplex RO 1 1.12 10BASE-T Full Duplex 1 = 10Mbps with full duplex 0 = no 10Mbps with full duplex capability RO 1 1.11 10BASE-T Half Duplex 1 = 10Mbps with half duplex 0 = no 10Mbps with half duplex capability RO 1 1.10:7 Reserved RO 0

1.6 No Preamble 1 = preamble suppression

0 = normal preamble RO 1

1.5 Auto-

1 = auto-negotiation process completed 0 = auto-negotiation process not completed RO 0

1.4 Remote Fault 1 = remote fault

0 = no remote fault RO/LH 0

1.3 Auto-

1 = capable to perform auto-negotiation 0 = unable to perform auto-negotiation RO 1

1.2 Link Status 1 = link is up

0 = link is down RO/LL 0

1.1 Jabber Detect 1 = jabber detected

0 = jabber not detected. Default is Low RO/LH 0

1.0 Extended

1 = supports extended capabilities registers RO 1 Register 2h – PHY Identifier 1 2.15:0 PHY ID Number Assigned to the 3rd through 18th bits of the Organizationally Unique Identifier (OUI). Kendin Communication’s OUI is 0010A1 (hex) RO 0022h Register 3h – PHY Identifier 2 3.15:10 PHY ID Number Assigned to the 19th through 24th bits of the Organizationally Unique Identifier (OUI). Kendin Communication’s OUI is 0010A1 (hex) RO 000101 3.9:4 Model Number Six bit manuf acturer’s model number RO 100001 3.3:0 Revision Number Four bit manufacturer’s model number RO 1010 Register 4h – Auto-Negotiation Advertisement

4.15 Next Page 1 = next page capable

0 = no next page capability. RW 0

4.14 Reserved RO 0

4.13 Remote Fault 1 = remote fault supported

0 = no remote fault RW 0 4.12 : 11 Reserved RO 0

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Address Name Description Mode Default

4.10 Pause 1 = pause function supported

0 = no pause function RW 0 4.9 100BASE-T4 1 = T4 capable 0 = no T4 capability RO 0 4.8 100BASE-TX Full Duplex 1 = TX with full duplex 0 = no TX full duplex capability RW Set by SPD100 & DUPLEX 4.7 100BASE-TX 1 = TX capable 0 = no TX capability RW Set by SPD100 4.6 10BASE-T Full Duplex 1 = 10Mbps with full duplex 0 = no 10Mbps full duplex capability RW Set by DUPLEX 4.5 10BASE-T 1 = 10Mbps capable 0 = no 10Mbps capability RW 1 4.4:0 Selector Field [0000 1] = IEEE 802.3 RW 00001 Register 5h – Auto-Negotiation Link Partner Ability

5.15 Next Page 1 = next page capable

0 = no next page capability RO 0

5.14 Acknowledge 1 = link code word received from partner

0 = link code word not yet received RO 0

5.13 Remote Fault 1 = remote fault detected

0 = no remote fault RO 0

5.12 Reserved RO 0

5.11:10 Pause 5.10 5 .11 No PAUSE Asymmetric PAUSE (link partner) Symmetric PAUSE Symmetric & Asymmetric PAUSE (local device) RO 0 5.9 100 BASE-T4 1 = T4 capable 0 = no T4 capability RO 0 5.8 100BASE-TX Full Duplex 1 = TX with full duplex 0 = no TX full duplex capability RO 0 5.7 100BASE-TX 1 = TX capable 0 = no TX capability RO 0 5.6 10BASE-T Full Duplex 1 = 10Mbps with full duplex 0 = no 10Mbps full duplex capability RO 0 5.5 10BASE-T 1 = 10Mbps capable 0 = no 10Mbps capability RO 0 5.4:0 Selector Field [0000 1] = IEEE 802.3 RO 00001 Register 6h – Auto-Negotiation Expansion 6.15:5 Reserved RO 0

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Address Name Description Mode Default

6.4 Parallel

1 = fault detected by parallel detection 0 = no fault detected by parallel detection. RO/ LH

6.3 Link Partner

1 = link partner has next page capability 0 = link partner does not have next page capability RO 0

6.2 Next Page

1 = local device has next page capability 0 = local device does not have next page capability RO 1

6.1 Page Received 1 = new page received

0 = new page not yet received RO/ LH

6.0 Link Partner

1 = link partner has auto-negotiation capability 0 = link partner does not have auto-negotiation capability RO 0 Register 7h – Auto-Negotiation Next Page

7.15 Next Page 1 = additional next page(s) will follow

0 = last page RW 0

7.14 Reserved RO 0

7.13 Message Page 1 = message page

0 = unformatted page RW 1

7.12 Acknowledge2 1 = will comply with message

0 = cannot comply with message RW 0

7.11 Toggle 1 = previous value of the transmitted link code

0 = logic Zero RO 0 7.10:0 Message Field 11-bit wide field to encode 2048 messages RW 001 Register 8h – Link Partner Next Page Ability

8.15 Next Page 1 = additional Next Page(s) will follow

0 = last page RO 0

8.14 Acknowledge 1 = successful receipt of link word

0 = no successful receipt of link word RO 0

8.13 Message Page 1 = Message Page

0 = Unformatted Page RO 0

8.12 Acknowledge2 1 = able to act on the information

0 = not able to act on the information RO 0

8.11 Toggle 1 = previous value of transmitted Link Code

0 = previous value of transmitted Link Code Word equal to logic one RO 0 8.10:0 Message Field RO 0 Register 15h – RXER Counter 15.15:0 RXER Counter RX Error counter for the RX_ER in each package RO 0000

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Address Name Description Mode Default Register 1bh – Interrupt Control/Status Register 1b.15 Jabber Interrupt Enable 1=Enable Jabber Interrupt 0=Disable Jabber Interrupt RW 0 1b.14 Receive Error Interrupt Enable 1=Enable Receive Error Interrupt 0=Disable Receive Error Interrupt RW 0 1b.13 Page Received Interrupt Enable 1=Enable Page Received Interrupt 0=Disable Page Received Interrupt RW 0 1b.12 Parallel Detect Fault Interrupt Enable 1= Enable Parallel Detect Fault Interrupt 0= Disable Parallel Detect Fault Interrupt RW 0 1b.11 Link Partner Acknowledge Interrupt Enable 1= Enable Link Partner Acknowledge Interrupt 0= Disable Link Partner Acknowledge Interrupt RW 0 1b.10 Link Down Interrupt Enable 1= Enable Link Down Interrupt 0= Disable Link Down Interrupt RW 0 1b.9 Remote Fault Interrupt Enable 1= Enable Remote Fault Interrupt 0= Disable Remote Fault Interrupt RW 0 1b.8 Link Up Interrupt Enable 1= Enable Link Up Interrupt 0= Disable Link Up Interrupt RW 0 1b.7 Jabber Interrupt 1= Jabber Interrupt Occurred 0= Jabber Interrupt Does Not Occurred RO/SC 0 1b.6 Receive Error Interrupt 1= Receive Error Occurred 0= Receive Error Does Not Occurred RO/SC 0 1b.5 Page Receive Interrupt 1= Page Receive Occurred 0= Page Receive Does Not Occurred RO/SC 0 1b.4 Parallel Detect Fault Interrupt 1= Parallel Detect Fault Occurred 0= Parallel Detect Fault Does Not Occurred RO/SC 0 1b.3 Link Partner Acknowledge Interrupt 1= Link Partner Acknowledge Occurred 0= Link Partner Acknowledge Does Not Occurred RO/SC 0 1b.2 Link Down Interrupt 1= Link Down Occurred 0= Link Down Does Not Occurred RO/SC 0 1b.1 Remote Fault Interrupt 1= Remote Fault Occurred 0= Remote Fault Does Not Occurred RO/SC 0 1b.0 Link Up Interrupt 1= Link Up Interrupt Occurred 0= Link Up Interrupt Does Not Occurred RO/SC 0 Register 1dh – LinkMD Control/Status Register 1d.15 Cable diagnostic test enable 0 = Indicates cable diagnostic test has completed and the status information is valid for read. 1 = the cable diagnostic test is activated. This bit is self-clearing. RW SC

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Address Name Description Mode Default 1d.14:13 Cable diagnostic test result [00] = normal condition [01] = open condition has been detected in cable [10] = short condition has been detected in cable [11] = cable diagnostic test failed RO 0 1d.12:9 Reserved 1d.8:0 Cable fault counter Distance to fault, approximately 0.39m*cabfaultcnt value RO 0 Register 1eh – PHY Control 1e:15:14 LED mode [00] = LED3 <- collision LED2 <- full duplex LED1 <- speed LED0 <- link/activity [01] = LED3 <- activity LED2 <- full duplex/collision LED1 <- speed LED0 <- link [10] = LED3 <- activity LED2 <- full duplex LED1 <- 100Mbps link LED0 <- 10Mbps link [11] = reserved RW 0 1e.13 Polarity 0 = Polarity is not reversed 1 = Polarity is reversed RO 1e.12 Far end fault detect 0 = Far end fault detected 1 = Far end fault not detected RO 1e.11 MDIX/MDI state 0 = MDIX 1 = MDI RO 1e:10:8 Reserved 1e:7 Remote loopback 0: normal mode 1: remote (analog) loop back is enable RW 0 1e:6:0 Reserved Register 1fh – 100BASE-TX PHY Controller 1f:15 Reserved

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Address Name Description Mode Default 1f:14 Mdi/mdix select when auto mdi/mdix is disable 0 = transmit on pair A (TPFINn/TPFIPn) and receive on pair B (TPFONn/TPFOPn). 1 = transmit on pair B (TPFONn/TPFOPn) and receive on pair A (TPFINn/TPFIPn). R/W 1f:13 Pairswap disable 1 = disable MDI/MDIX 0 = enable MDI/MDIX R/W 0 1f.12 Energy detect 1 = presence of signal on RX+/- analog wire pair 0 = no signal detected on RX+/- RO 0 1f.11 Force link 1 = force link pass 0 = normal link operation This bit bypasses the control logic and allow transmitter to send pattern even if there is no link. R/W 0 1f.10 Power Saving 1 = enable power saving 0 = disable RW 1 1f.9 Interrupt Level 1 = interrupt pin active high 0 = active low RW 0 1f.8 Enable Jabber 1 = enable jabber counter 0 = disable RW 1 1f.7 Auto- Negotiation Complete 1 = auto-negotiation complete 0 = not complete RW 0 1f.6 Enable Pause (Flow-Control Result) 1 = flow control capable 0 = no flow control RO 0 1f.5 PHY Isolate 1 = PHY in isolate mode 0 = not isolated RO 0 1f.4:2 Operation Mode Indication [000] = still in auto-negotiation [001] = 10BASE-T half duplex [010] = 100BASE-TX half duplex [011] = default [101] = 10BASE-T full duplex [110] = 100BASE-TX full duplex [111] = PHY/MII isolate RO 0 1f.1 Enable SQE test 1 = enable SQE test 0 = disable RW 0 1f.0 Disable Data Scrambling 1 = disable scrambler 0 = enable RW 0

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Absolute Maximum Rating (Note 1) Storage Temperature (TS) ……………… -55 °C to +150°C Supply Referenced to GND…… ………-0.5V to +4.0 Important: Please read the Notes at the bottom of the page. Operating Range (Note 2) Supply Voltage (VDD_PLL, VDD_TX, VDD_RXC, VDDC)…………1.8V ± 5% Ambient Temperature Commercial (TA)...…0 °C to +70°C Ambient Temperature Industrial (TA)….…-40 °C to +85°C

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Package Thermal Resistance (θJA)(Note 3) Thermal Resistance θJA θJA θJA θJC Airflow Velocity (m/s) 0 1 2 0 LQFP 83.56 77.08 72.36 46.93 SSOP 75.19 68.20 66.20 TBD Electrical Characteristics (Note4) VDD=3.3V ±10% Symbol Parameter Condition Min Typ Max Units Total Supply Current (including TX output drive current) (Note 5) IDD1 Normal 100BASE-TX Includi ng 40mA output current mA IDD2 Normal 10BASE-T Including 90mA output current, indepdendent of utilization mA IDD3 Power Saving Mode 1 Auto-negotiation is Enabled mA IDD4 Power Down Mode (software power down) mA IDD5 Power down pin (PD#) TTL Inputs VIH Input High Voltage ½ VDD (I/O) + 0.2 V VIL Input Low Voltage 0.8 V IIN Input Current V IN = GND – VDD -10 10 µA TTL Outputs VOH Output High Voltage I OH = -4mA ½ VDD (I/O) + 0.6 V VOL Output Low Voltage 0.4 V I IOZ I Output Tri-State Leakage 10 µA 100BASE-TX Transmit (measured differentially after 1:1 transformer) VO Peak Differential Ouput Voltage 50Ω from each output to VDD 0.95 1.05 V VIMB Output Voltage Imbalance 50Ω from each output to VDD 2 % tr, tt Rise/Fall Time Rise/Fall Time Imbalance 3 0 5 0.5 ns ns Duty Cycle Distortion ±0.5 ns Overshoot % VSET Refernce Voltage of ISET 0.75 V Propagation Delay 45 60 ns Jitter 0.7 1.4 ns (pk-pk) 10BASE-T Transmit (measured differentially after 1:1 transformer)

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. VP Peak Differential Ouput Voltage 50Ω from each output to VDD 2.2 2.8 V VIMB Output Voltage Imbalance 50Ω from each output to VDD ±3.5 ns tr, tt Rise/Fall Time 25 ns Clock Outputs X1, X2 Crystal Oscillator 25 MHz RXC100 Receive Clock, 100TX 25 MHz RXC10 Receive Clock, 10T 2.5 MHz Receive Clock Jitter 3.0 ns (pk-pk) TXC100 Transmit Clock, 100TX 25 MHz TXC10 Transmit Clock, 10T 2.5 MHz Transmit Clock Jitter 1.8 ns (pk-pk) Note 1: Exceeding the absolute rating(s) may cause permanent dam age to the device. Operating at maximum conditions for extended periods may affect device reliability. Note 2: This device is not guaranteed to operate beyond its s pecified operating rating. Unused inputs must always be tied to an appropriate logic voltage level (Ground to VDD). Note 3: No HS (heat spreader) in package. Note 4: Specification for packaged product only. Note 5: 100% data transmission in full-duplex mode and minimum IPG with 130-meter cable.

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Timing Diagrams 10BaseT MII Transmit Timing TXC min. typ. max. tSU1 TXD[3:0] Setup to TXC High 10ns tSU2 TXEN Setup to TXC High 10ns tHD1 TXD[3:0] Hold after TXC High 0ns tHD2 TXEN Hold after TXC High 0ns tCRS1 TXEN High to CRS asserted latency 4BT tCRS2 TXEN Low to CRS de-asserted latency 8BT tLAT TXEN High to TXP/TXM output (TX latency) 4BT tSQE COL (SQE) Delay after TXEN de-asserted 2.5us tSQEP COL (SQE) Pulse Duration 1.0us tHD2 tSU2TXEN TXD[3:0] tSU1 tHD1 CRS tCRS2 tCRS1 TXP/TXM tLAT Valid Data TXC tSQE COL tSQEP SQE Timing TXEN

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. 100BaseTX MII Transmit Timing TXC tSU2 min. typ. max. tSU1 TXD[3:0] Setup to TXC High 10ns tSU2 TX_ER Setup to TXC High 10ns tHD1 TXD[3:0] Hold after TXC High 0ns tHD2 TXER Hold after TXC High 0ns tHD3 TXEN Hold after TXC High 0ns tCRS1 TXEN High to CRS asserted latency 4BT tCRS2 TXEN Low to CRS de-asserted latency 4BT tLAT TXEN High to TX+/TX- output (TX latency) 7BT TXEN tHD2 TXD[3:0], TXER tSU1 CRS tCRS2 tCRS1 TX+/TX- tLAT Symbol Out Data In tHD1

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. 100BaseTX MII Receive Timing min. typ. max. tP RXC period 40ns tWL RXC pulse width 20ns tWH RXC pulse width 20ns tSU RXD[3:0], RXER, RXDV setup to rising edge of RXC 20ns tHD RXD[3:0], RXER, RXDV hold from rising edge of RXC 20ns tRLAT CRS to RXD latency, 4B or 5B aligned 1BT 2BT 3BT tCRS1 "Start of Stream" to CRS asserted 140ns tCRS2 "End of Stream" to CRS de-asserted 170ns RX+/RX- RXD[3:0] RXER CRS tCRS1 tCRS2 RXDV tRLAT tSU tHD Start of Stream End of Stream RXC tWL tWH tP

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Auto Negotiation / Fast Link Pulse Timing tPW min. typ. max. tBTB FLP burst to FLP burst 8ms 16ms 24ms tFLPW FLP burst width 2ms tPW Clock/Data pulse width 100ns tCTD Clock pulse to data pulse 69us tCTC Clock pulse to clock pulse 136us Number of Clock/Data pulses per burst 17 33 TX+/TX- Clock Pulse Data Pulse Clock Pulse tPW tCTD tCTC tFLPW tBTB TX+/TX- Data Pulse FLP Burst FLP Burst

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Serial Management Interface Timing min. typ. max. tP MDC period 400 ns tMD1 MDIO Setup to MDC (MDIO as input) 10ns tMD2 MDIO Hold after MDC (MDIO as input) 10ns tMD3 MDC to MDIO Valid (MDIO as output) 222ns tMD1 Valid Data MDIO (Into Chip) Valid Data MDC tMD2 MDIO (Out of Chip) Valid Data tMD3 tP

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Reset Timing Diagram tsr Supply Voltage RST_N Strap-In Value Reset Timing Parameters Parameter Description Min Max Units tsr Stable supply voltages to reset high 50 us Reset Circuit Diagram Micrel recommends the following discrete reset circuit as sh own in Figure 1 when powering up the KS8001 device. For the application where the reset circuit signal comes from another device (e.g., CPU, FPGA, etc), we recommend the reset circuit as shown in Figure 2. KS8001 CPU/FPGA VCC C 10uF R 10K RST RST_OUT_n D1, D2: 1N4148 Recommended Reset Circuit

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. KS8001 VCC RST D1: 1N4148 R 10K C 10uF Recommended Circuit for Interfacing with CPU/FPGA Reset At power-on-reset, R, C, and D1 provide the necessary ramp rise time to re set the Micrel device. The reset out from CPU/FPGA provides warm reset after power up. It is also recommend to power up VDD core voltage earlier than VDDIO voltage. At worst case, the both VDD core and VDDIO voltages should come up at the same time.

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Reference Circuit for Strapping Option Configuration The Figure shows the reference circuit for strapping option pins KS8001 LED pin 220Ω 10ΚΩ 3.3 V Reference circuits for unmanaged programming through LED ports KS8001 LED pin 220Ω 1ΚΩ 3.3 V Pull Down Pull Up

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE. Selection of Isolation Transformers A 1:1 isolation transformer is required at the line interface. An isolation transfo rmer with integrated common-mode choke is recommended for exceeding FCC requirements. The following table gives recommended transformer characteristics. Transformer Selection Criteria Parameter Value Test Condition Turns Ratio 1 CT : 1 CT Open-Circuit Inductance (min.) 350 uH 100 mV, 100 kHz, 8 mA Leakage Inductance (max.) 0.4 uH 1 MHz (min.) Inter-Winding Capacitance (max.) 12 pF D.C. Resistance (max.) 0.9 Ohms Insertion Loss (max.) 1.0 dB 0-65 MHz HIPOT (min.) 1500 Vrms Magnetic Vendor Selection Lists Single Port Magnetic manufacturer Part number AUTO MDIX Number of port Pulse H1102 Yes 1 Bel Fuse S558-5999-U7 Yes 1 Bel Fuse SI-46001 Yes 1 Bel Fuse SI-50170 Yes 1 YCL PT163020 Yes 1 Transpower HB726 Yes 1 Delta LF8505 Yes 1 LanKom LF-H41S Yes 1 Selection of Reference Crystal An oscillator or crystal with the following typical characteristics is recommended. Charateristics Value Units Frequency 25.00000 MHz Frequency Tolerance(max) ± 50 ppm Load Capacitance (max) 20 pF Series Resistance 40 Ω

May 2005 – SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE KS8001 MICREL CONFIDENTIAL. DO NOT DISTRIBUTE.

Package Information