MODEL: KSP KSP SPECIFICATIONS ES-3572-ME Rev.3 Page 1/3 http://www.m-system.co.jp/ Plug-in Signal Conditioners K-UNIT LOW FREQUENCY TRANSMITTER (50 Hz minimum, for Mitsubishi inverter) Functions & Features
- Converting the pulse output from FM terminal of Mitsubishi inverter into standard process signal
- Isolation up to 2000 V AC
- High-density mounting Typical Applications
- Positive displacement flowmeters, turbine flowmeters and vortex flowmeters
- Proximity switches (1.97) 123 (4.84) (3.15) mm (inch) K-UNIT MODEL: KSP-2[1]-[2]-ME
ORDERING INFORMATION
- Code number: KSP-2[1]-[2]-ME Specify a code from below for each of [1] and [2]. (e.g. KSP-2A-B-ME)
- Frequency range (e.g. 0 – 1440 Hz) INPUT 2: Voltage pulse [1] OUTPUT Current A: 4 – 20 mA DC (Load resistance 750 Ω max.) B: 2 – 10 mA DC (Load resistance 1500 Ω max.) C: 1 – 5 mA DC (Load resistance 3000 Ω max.) D: 0 – 20 mA DC (Load resistance 750 Ω max.) E: 0 – 16 mA DC (Load resistance 900 Ω max.) F: 0 – 10 mA DC (Load resistance 1500 Ω max.) G: 0 – 1 mA DC (Load resistance 15 kΩ max.) Z: Specify current (See OUTPUT SPECIFICATIONS) Voltage 1: 0 – 10 mV DC (Load resistance 10 kΩ min.) 2: 0 – 100 mV DC (Load resistance 100 kΩ min.) 3: 0 – 1 V DC (Load resistance 100 Ω min.) 4: 0 – 10 V DC (Load resistance 1000 Ω min.) 5: 0 – 5 V DC (Load resistance 500 Ω min.) 6: 1 – 5 V DC (Load resistance 500 Ω min.) 4W: -10 – +10 V DC (Load resistance 2000 Ω min.) 5W: -5 – +5 V DC (Load resistance 1000 Ω min.) 0: Specify voltage (See OUTPUT SPECIFICATIONS) [2] POWER INPUT AC Power B: 100 V AC C: 110 V AC D: 115 V AC F: 120 V AC G: 200 V AC H: 220 V AC J: 240 V AC DC Power S: 12 V DC R: 24 V DC GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3.5 screw terminals Housing material: Flame-resistant resin (black) Isolation: Input to output to power Overrange output: 0 to 120 % at 1 – 5 V Zero adjustment: -5 to +5 % (front) Span adjustment: 95 to 105 % (front) Input pulse sensing: DC coupled standard Input filter: CR filter incorporated (C = 3.3 nF, R = 10 kΩ; parallel connection) Low-end cutout: 2 to 5 % Applicable inverter: Mitsubishi electric FREQROL series: A024, A200, A500, A700, A800, D700, E500, E700, F400, F500, F700, F700PJ, F800, S500, U100, B, B3 Mitsubishi electric MELTRAC series: A100, A200, V200 Note) Do NOT connect other devices except the transmitter to the inverter's FM terminal. Do NOT bundle the FM and motor wirings. INPUT SPECIFICATIONS Frequency range: 0 – 50 Hz through 0 - 1440 Hz Pulse width (time) requirement: ≥ 280 μsec. (Hi and Lo) ■ Voltage Pulse Waveform: Square Input amplitude: VH 4 ±0.7 - 50 V, VL 1 ± 0.7 V Input impedance: ≥ 7 kΩ (for 9 V DC pulse)
MODEL: KSP KSP SPECIFICATIONS ES-3572-ME Rev.3 Page 2/3 http://www.m-system.co.jp/ OUTPUT SPECIFICATIONS ■ DC Current: 0 – 20 mA DC Minimum span: 1 mA Offset: Max. 1.5 times span Load resistance: Output drive 15 V max. ■ DC Voltage: -10 – +12 V DC Minimum span: 5 mV Offset: Max. 1.5 times span Load resistance: Output drive 10 mA max.; 5 mA for negative voltage output; at ≥ 0.5 V INSTALLATION Power input
- AC: Operational voltage range: rating ±10 %, 50/60 ± 2 Hz, approx. 2.5 VA
- DC: Operational voltage range: rating ±10 %, ripple 10% p-p max.; approx. 2.5 W (100 mA at 24 V) Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 350 g (0.77 lb) PERFORMANCE in percentage of span Accuracy: ± 0.3 % (output 10 – 100 %) Temp. coefficient: ±0.02 %/°C (±0.01 %/°F) Response time: (0 – 90 %) Approx. 2 sec. for 0 – 50 Hz Approx. 1 sec. for 0 – 100 Hz Approx. 0.5 sec. for 0 – 500 Hz Approx. 0.5 sec. for 0 – 10 kHz Ripple: 0.2 %p-p max. with input ≥ 10 % Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 3456 2187 80 (3.15) 80 (3.15) (.79) 40 (1 .57) 50 (1 .97) 7 .8 (.31) CLAMP (top & bottom) DIN RAIL 35mm wide2–4.5 (.18) dia. MTG HOLE 15 (.59) deep 8–M3.5 SCREW
- When mounting, no extra space is needed between units.
MODEL: KSP KSP SPECIFICATIONS ES-3572-ME Rev.3 Page 3/3 http://www.m-system.co.jp/ SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Isolation Base Socket Waveform Shaper Output Driver OUTPUT Z S U(+) V(–) POWER One-Shot+ INPUT Integration10kΩ 3.3nF Note: Do NOT connect other devices except the transmitter to the inverter’s FM terminal. Do NOT bundle the FM and motor wirings. Specifications are subject to change without notice.