© 2016 Littelfuse Protection Relays & Controls Time Delay Relays Dedicated - Delay-on-Break Rev: 1-A-062216 www.littelfuse.com/ksdb KSDB SERIES
Description
The KSDB Series is designed for general purpose commercial and industrial applications where a small, cost effective, reliable solid-state timer is required. The factory calibration for fixed time delays is within 5% of the target time delay. The repeat accuracy, under stable conditions, is 0.5% of the selected time delay. This series is designed for popular AC and DC voltages. Time delays of 0.1 seconds to 1000 minutes are available in 6 ranges. The output is rated 1A steady and 10A inrush. The modules are totally solid state and encapsulated to protect the electronic circuitry. Operation (Delay-on-Break) Input voltage must be applied before and during timing. Upon closure of the initiate switch, the output energizes. The time delay begins when the initiate switch is opened. The output remains energized during timing. At the end of the time delay, the output de-energizes. The output energizes if the initiate switch is closed when input voltage is applied. Reset: Reclosing the initiate switch during timing resets the time delay. Loss of input voltage resets the time delay and output. Features & Benefits FEATURES BENEFITS Microcontroller based Repeat accuracy + / - 0.5%, Factory calibration + / - 5% 1A Steady, 10A inrush solid-state output Provides 100 million operations in typical conditions. T otally solid state and encapsulated No moving parts to arc and wear out over time and encapsulated to protect against shock, vibration, and humidity Compact, low cost design Allows flexibility for OEM applications Wiring Diagram V = Voltage UTL = Optional Untimed Load L = Load S1 = Initiate Switch RT is used when external adjustment is ordered. L1 N/L2 (Positive Switching) (Negative Switching)
Ordering Information
VOLTAGE ADJUSTMENT TIME DELAY SWITCHING MODE MODEL INPUT VOLTAGE ADJUSTMENT TIME DELAY SWITCHING MODE KSDB1110MP 12VDC Fixed 10m Positive KSDB314SP 24VDC Fixed 4s Positive KSDB1115SP 12VDC Fixed 15s Positive KSDB315SP 24VDC Fixed 5s Positive KSDB1120SP 12VDC Fixed 20s Positive KSDB324N 24VDC External 1 - 100m Negative KSDB113MP 12VDC Fixed 3m Positive KSDB330N 24VDC Onboard 0.1 - 10s Negative KSDB113SP 12VDC Fixed 3s Positive KSDB4120M 120VAC Fixed 20m n/a KSDB120P 12VDC External 0.1 - 10s Positive KSDB4160S 120VAC Fixed 60s n/a KSDB134P 12VDC Onboard 1 - 100m Positive KSDB4190M 120VAC Fixed 90m n/a KSDB2115S 24VAC Fixed 15s n/a KSDB431 120VAC Onboard 1 - 100s n/a KSDB220 24VAC External 0.1 - 10s n/a KSDB61150S 230VAC Fixed 150s n/a KSDB231 24VAC Onboard 1 - 100s n/a KSDB631 230VAC Onboard 1 - 100s n/a If you don’t find the part you need, call us for a custom product 800-843-8848
© 2016 Littelfuse Protection Relays & Controls Time Delay Relays Dedicated - Delay-on-Break Rev: 1-A-062216 www.littelfuse.com/ksdb Accessories P1004-95, P1004-95-X Versa-Pot Panel mountable, industrial potentiometer recommended for remote time delay adjustment. P1023-6 Mounting bracket The 90° orientation of mounting slots makes installation/removal of modules quick and easy. P0700-7 Versa-Knob Designed for 0.25 in (6.35 mm) shaft of Versa-Pot. Semi-gloss industrial black finish. P1015-64 (AWG 14/16), P1015-14 (AWG 18/22) Female Quick Connect These 0.25 in. (6.35 mm) female terminals are constructed with an insulator barrel to provide strain relief. P1015-18 Quick Connect to Screw Adapter Screw adapter terminal designed for use with all modules with 0.25 in. (6.35 mm) male quick connect terminals. C103PM (AL) DIN Rail 35 mm aluminum DIN rail available in a 36 in. (91 .4 cm) length. P1023-20 DIN Rail Adapter Allows module to be mounted on a 35 mm DIN type rail with two #10 screws. External Resistance vs. Time Delay This chart applies to externally adjustable part numbers. The time delay is adjustable over the time delay range selected by varying the resistance across the RT terminals; as the resistance increases the tie delay increases. When selecting an external RT, add the tolerances of the timer and the RT for the full time range adjustment. Examples: 1 to 50 S adjustable time delay, select time delay range 1 and a 50 K ohn RT. For 1 to 100 S use a 100 K ohm RT. KSDB SERIES Specifications Time Delay Range 0.1s - 1000m in 6 adjustable ranges or fixed Repeat Accuracy ±0.5 % or 20ms, whichever is greater Tolerance (Factory Calibration) ≤ ±5% Reset Time ≤ 150ms Initiate Time ≤ 20ms Time Delay vs Temp. & Voltage ≤ ±10% Input Voltage 12, 24, or 120VDC; 24, 120, or 230VAC Tolerance ±20% Power Consumption AC ≤ 2VA; DC ≤ 2W AC Line Frequency/DC Ripple 50/60 Hz / ≤ 10 % Output Type Solid state Form NO, closed before & during timing Maximum Load Current 1A steady state, 10A inrush at 60°C OFF State Leakage Current AC≅ 5mA @ 230VAC; DC ≅ 1mA Voltage Drop AC ≅ 2.5V @ 1A; DC ≅ 1V @ 1A DC Operation Positive or negative switching Protection Circuitry Encapsulated Dielectric Breakdown ≥ 2000V RMS terminals to mounting surface Insulation Resistance ≥ 100 MΩ Polarity DC units are reverse polarity protected Mechanical Mounting Surface mount with one #10 (M5 x 0.8) screw Dimensions H 50.8 mm (2.0”); W 50.8 mm (2.0”); D 30.7 mm (1.21”) Termination 0.25 in. (6.35 mm) male quick connect terminals Environmental Operating/Storage Temperature -40° to 60°C / -40° to 80°C Humidity 95% relative, non-condensing Weight ≅ 2.4 oz (68 g) Function Diagram DELAY-ON-BREAK (OFF-DELAY) V = Voltage S1 = Initiate Switch NO = Normally Open Contact NC = Normally Closed Contact TD = Time Delay t = Incomplete Time Delay R = Reset = Undefined Time