KQWS DIWELL | Alldatasheet

Document overview

  • PDF pages: 7

Technical content

DANUBE http://www.danube.com.tw 1 2016/03/11

FEATURES

 40W DIL PACKAGE  INDUSTRY STANDARD PACKAGE INPUT RANGE  100% BURNED IN  HIGH EFFICIENCY  UL 94V-0 PACKAGE MATERIAL  CUSTOM SOLUTIONS AVAILABLE  3 YEARS WARRANTY OUTPUT SPECIFICATIONS INPUT SPECIFICATIONS Voltage Setpoint Accuracy +/-2% max. Input Voltage Range 2:1 or 4:1 Input Range Over Voltage Protection Built-in Input Filter Pi Network Temperature Coefficient +/-0.03%/°C Protection Fuse Recommended Ripple & Noise(20MHz BW)1 100mVp-p max. Start up time(Nominal input) 10ms max. Line Regulation2 +/-0.5% max. GENERAL SPECIFICATIONS Load Regulation3 +/-0.5% max. Efficiency 90% typ. Minimum load 10% of Full Load Isolation Voltage (Input / Output / case) 1500 VDC min. Short Circuit Protection Continuous Isolation Voltage4 1500 VDC min. Short Circuit Restart Automatic Isolation Resistance 109 ohms min. External Trim Adj. Range +/-10% Isolation Capacitance 2500pF max. Over Load Protection 150% typ. Switching Frequency 250KHz typ. Transient Response5 500uS max. Weight 50g typ. Case Material Six-Side Shielded Case Case Size 50.8mm*50.8mm*11mm Potting Material Epoxy(UL94-V0) ENVIRONMENTAL SPECIFICATIONS Conducted Emissions EN55022 Class A Operating Temperature Radiated Emissions EN55022 Class A No Heat Sink -40°C to +60°C With Heat Sink -40°C to +75°C Case Temperature +100°C max. Storage Temperature -55°C to +100°C Humidity 95% max. Cooling Free-Air Convection ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD , AND 25 °C UNLESS OTHERWISE NOTED. 1 Measured with 1uF ceramic capacitor connect to the output pins. 2 High Line to Low Line. 3 Load Regulation is for output load current change from 10% to 100%. 4 For 10 seconds. 5 50% Step Load Change. KQWS SERIES 40W WIDE INPUT RANGE

DANUBE http://www.danube.com.tw 2 2016/03/11  SELECTION GUIDE(1) 2:1 33W~40W OUTPUT MODEL NUMBER INPUT VOLTAGE (VDC) OUTPUT VOLTAGE (VDC) OUTPUT CURRENT (mA) INPUT6 CURRENT(mA) EFF (%)7 CAPACITOR LOAD (Max) FULL LOAD NO LOAD KQWS-1203.3(HS) 9-18 3.3 10000 3125 150 88 4700uF KQWS-1205(HS) 9-18 5 8000 3663 150 91 4700uF KQWS-1209(HS) 9-18 9 4444 3663 150 91 3300uF KQWS-1212(HS) 9-18 12 3333 3703 150 90 1500uF KQWS-1215(HS) 9-18 15 2667 3703 150 90 820uF KQWS-2403.3(HS) 18-36 3.3 10000 1545 100 89 4700uF KQWS-2405(HS) 18-36 5 8000 1785 100 93 4700uF KQWS-2409(HS) 18-36 9 4444 1832 100 91 3300uF KQWS-2412(HS) 18-36 12 3333 1832 100 91 1500uF KQWS-2415(HS) 18-36 15 2667 1825 100 91 820uF KQWS-4803.3(HS) 36-75 3.3 10000 764 40 90 4700uF KQWS-4805(HS) 36-75 5 8000 906 40 92 4700uF KQWS-4809(HS) 36-75 9 4444 916 40 91 3300uF KQWS-4812(HS) 36-75 12 3333 920 40 91 1500uF KQWS-4815(HS) 36-75 15 2667 920 40 91 820uF Note: Other input to output voltages may be available. Please contact factory. 6 NOMINAL INPUT VOLTAGE. 7 NOMINAL INPUT VOLTAGE,FULL LOAD.

DANUBE http://www.danube.com.tw 3 2016/03/11  SELECTION GUIDE(2) 4:1 33W~40W OUTPUT MODEL NUMBER INPUT VOLTAGE (VDC) OUTPUT VOLTAGE (VDC) OUTPUT CURRENT (mA) INPUT8 CURRENT(mA) EFF (%)9 CAPACITOR LOAD (Max) FULL LOAD NO LOAD KQWS-1203.3T(HS) 9-36 3.3 10000 3161 150 87 4700uF KQWS-1205T(HS) 9-36 5 8000 3745 150 89 4700uF KQWS-1209T(HS) 9-36 9 4444 3745 150 89 3300uF KQWS-1212T(HS) 9-36 12 3333 3704 150 90 950uF KQWS-1215T(HS) 9-36 15 2667 3704 150 90 820uF KQWS-2403.3T(HS) 18-75 3.3 10000 1580 100 87 4700uF KQWS-2405T(HS) 18-75 5 8000 1873 100 89 4700uF KQWS-2409T(HS) 18-75 9 4444 1873 100 89 3300uF KQWS-2412T(HS) 18-75 12 3333 1894 100 88 950uF KQWS-2415T(HS) 18-75 15 2667 1852 100 90 820uF Note: Other input to output voltages may be available. Please contact factory.  PART NUMBERS STRUCTURE Model Name Difference KQWv-x1x2T(HSJ) KQ=Series Name W=Wide Input Range v=Type of output voltage (S=single output) x1=Input voltage(9~18V;18~36V;36~75V;9~36V;18-75V) x2=Output voltage(03.3;05;09;12;15 ) T= Input Range 4:1 HS=With Heat Sink zzz= 0~9,A~Z or blank for market purpose. J=Pin Length 3.5 mm 8 NOMINAL INPUT VOLTAGE. 9 NOMINAL INPUT VOLTAGE,FULL LOAD.

DANUBE http://www.danube.com.tw 4 2016/03/11  SIMPLIFIED SCHEMATIC -Vin +Vin +Vout -Vout REFERENCE ERROR AMP ISOLATIONPWM CONTROLLER  MECHANICAL DIMENSIONS PIN SINGLE

1 Remote On/Off

8 Trim

NOTE:Pin Size is Tolerance 1.0Φ ±0.10mm All Dimensions In mm(Inches) Tolerance .X or .XX= ±0.5mm

DANUBE http://www.danube.com.tw 5 2016/03/11 Remote On/Off Control Control Input PIN1 Control Common PIN2 Control Voltage Converter Shutdown Idle Current 10mA ON >+2.5VDC or Open Circuit Logic Compatibility CMOS or Open Collector TTL OFF <+0.5VDC or Jumper to PIN 2  TYPICAL APPLICATIONS FIXED VOLTAGE OUTPUT TRIM CONNECTIONS USING A TRIMPOT FIXED-VALUE TRIM DOWN RESISTOR FIXED-VALUE TRIM UP RESISTOR  RECOMMENDED FOOTPRINT DETAILS 123 754 6 8 GRID : 2.54mm TOP VIEW

DANUBE http://www.danube.com.tw 6 2016/03/11  TYPICAL PERFORMANCE CURVES Specifications typical at Ta=25 OC, nominal input voltage , rated output current unless otherwise specified. OUTPUT LOAD VS EFFICIENCY 0.0 20.0 40.0 60.0 80.0 100.0 0 20 40 60 80 100 OF RATED LOAD(%) EFFICIENCY(%) TEMPERATURE DERATING 100 125 -40 0 60 75 100 TA(degree C) OUTPUT POWER(%) No Heat-Sink w ith Heat-Sink  INPUT FUSE SELECTION GUIDE 9-18V or 9-36V INPUT VOLTAGE(VDC) 18-36V or 18-75V INPUT VOLTAGE(VDC) 36-75V INPUT VOLTAGE(VDC) 10000mA Slow-Blow Type 6000mA Slow-Blow Type 3000mA Slow-Blow Type DC-DC CONVERTER +Vin -Vin +Vout -Vout OUTPUT Fuse INPUT Note: Certain applications may require the installation of external fuse in front of the input. SAFE OPERATING AREA

DANUBE http://www.danube.com.tw 7 2016/03/11 KQWS SERIES APPLICATION NOTES: EXTERNAL CAPACITANCE REQUIREMENTS: External output capacitance is not required for operation, however it is recommended that 10uF MLCC and 0.1uF ceramic capacitance be selected for reduced system noise. Additional output capacitance may be added for increased filtering, but should not exceed 1000uF. Negative Outputs: A negative output voltage may be obtained by connecting the +OUT to circuit ground and connecting –OUT as the negative output. Remote ON/OFF: The remote ON/OFF pin may be left floating if this function is not use. It is recommended to drive t his pin with an open collector arrangement or a relay contact. When the ON/OFF pin is pulled low with respect to the –Vin , the converter is placed in a low power drain state. Output TRIM: The TRIM pin may be used to adjust the output +/ -10% from the nominal setting .this function allows adjustment for voltage drops in the system wiring. If the TRIM function is not required the pin may be left floating. FOR MORE INFORMATION CALL: Danube Enterprise Co., Ltd. Tel: 886-7-3755165 Fax: 886-7-3755330 E-mail: danube@ms10.hinet.net Home Page http://www.danube.com.tw