Product specification – April 1, 2024 V.5 DATA SHEET WIREWOUND RESISTORS General Purpose KNP Series ±1%, ±2%, ±5% 1/4W to 7W RoHS compliant & Halogen Free
www.yageo.com Apr. 01, 2024 V.5
APPLICATIONS
Power applications Home appliance Industry
FEATURES
Higher power rating Wide resistance range High stable performance and high reliability Flameproof coating equivalent to UL-94V-0 RoHS compliant & halogen- free
ORDERING INFORMATION
Part number of the wirewound resistor is identified by the series, power rating, tolerance, packing, temperature coefficient, forming and resistance value and suffix. PART NUMBER KNP 2WS J T - 73- 30R NO (1) SERIES KNP Series (2) POWER RATING -25 = 1/4W 50S = 1/2W -50 = 1/2W 1WS = 1W 100 = 1W 2WS = 2W 200 = 2W 3WS = 3W 3SS = 3W 300 = 3W 400 = 4W 5WS = 5W 500 = 5W 600 = 6W 700 = 7W 7WS = 7W (3) TOLERANCE (4) PACKAGING T = Box Pack R = Reel Pack B = Bulk (5) TEMPERATURE COEFFICIENT OF RESISTANCE - = Based on spec. (6) FORMING 52- = 52.4mm 73- = 73mm 91- = 91mm M = M-Type Forming MB = M-form W/flat F = F Type FK = FK Type FFK = F-form Kink FKK = FKK Type FT = FT Type Forming PN = PANAsert AV = AVIsert Note: 52.4mm,73mm and 91mm represent dimension A of the axial type, please refer to the category of AXIAL/REEL TAPE SPECIFICATION for the detail. (7) RESISTANCE VALUE E24 & E96 Series Example: 0R1= 0.1Ω, 100R= 100Ω, 1K = 1,000Ω (8) SUFFIX Optional code. required only when resistor is with pulse/surge specification. Example: NO, CM, CN, CU, CY, FB, FC, NS, NM, CR, NL, NJ etc. Null = Standard Type.
www.yageo.com Apr. 01, 2024 V.5 DIMENSIONS Unit: mm Normal Miniature L ψD H ψd DERATING CURVE KNP300 ~ KNP700 Rated Power (%)1008060402040 200 275 Ambient Temperature (°C)31 KNP-25 ~ KNP3WS Rated Power (%)1008060402070 200 275 Ambient Temperature (°C)36
www.yageo.com Apr. 01, 2024 V.5
ELECTRICAL CHARACTERISTICS
CHARACTERISTICS KNP-25 KNP-50 KNP100 KNP200 KNP300 KNP400 KNP500 KNP600 KNP700 Power Rating at 40 °C 3W 4W 5W 6W 7W Power Rating at 70 °C 1/4W 1/2W 1W 2W Resistance Range (±1%) 0.1Ω - 150Ω 0.1Ω - 750Ω 0.1Ω - 1.5KΩ 0.1Ω - 2.4KΩ 0.1Ω - 3.3KΩ 0.1Ω - 3.3KΩ 0.1Ω - 6.2KΩ 0.1Ω - 6.2KΩ 0.1Ω - 6.2KΩ Resistance Range (±2% & ±5%) 0.1Ω - 200Ω 0.1Ω - 800Ω 0.1Ω - 2.2KΩ 0.1Ω - 2.7KΩ 0.1Ω - 3.9KΩ 0.1Ω - 3.9KΩ 0.1Ω - 6.8KΩ 0.1Ω - 6.8KΩ 0.1Ω - 6.8KΩ Voltage Proof on Insulation 250V 300V 400V 400V 400V 400V 400V 400V 400V Maximum working voltage √(P X R) Operating Temp. Range - 40°C to +200°C Temperature Coefficient ±300ppm/°C Note: For resistance value out of above range is by request. CHARACTERISTICS KNP50S KNP1WS KNP2WS KNP3SS KNP3WS KNP5WS KNP7WS Power Rating at 40 °C 5W 7W Power Rating at 70 °C 1/2W 1W 2W 3W 3W Resistance Range (±1%) 0.1Ω - 150Ω 0.1Ω - 750Ω 0.1Ω - 1.5KΩ 0.1Ω - 1.5KΩ 0.1Ω - 2.4KΩ 0.1Ω - 3.3KΩ 0.1Ω - 3.3KΩ Resistance Range (±2% & ±5%) 0.1Ω - 200Ω 0.1Ω - 800Ω 0.1Ω - 2.2KΩ 0.1Ω - 2.2KΩ 0.1Ω - 2.7KΩ 0.1Ω - 3.9KΩ 0.1Ω - 3.9KΩ Voltage Proof on Insulation 200V 300V 400V 400V 400V 400V 400V Maximum working voltage √(P X R) Operating Temp. Range - 40°C to +200°C Temperature Coefficient ±300ppm/°C Note: For resistance value out of above range is by request.
www.yageo.com Apr. 01, 2024 V.5 TEST AND REQUIRMENTS TEST TEST METHOD PROCEDURE APPRAISE Short Time Overload IEC 60115-1 4.13 10 times rated power for 5 sec. ±2%+0.05Ω Voltage Proof on Insulation IEC 60115-1 4.7 In V-Block for 60 sec. test voltage as above table No Breakdown Temperature Coefficient IEC 60115-1 4.8 Between -40°C to +155°C By Type Insulation Resistance IEC 60115-1 4.6 In V-Block for 60 sec. >100MΩ Solderability IEC 60115-1 4.17 245±5°C for 3±0.5 Sec. 95% Min. coverage Solvent Resistance of Marking IEC 60115-1 4.30 IPA for 5±0.5 Min. with ultrasonic No deterioration of coatings and markings Robustness of Terminations IEC 60115-1 4.16 Direct load for 10 Sec. in the direction of the terminal leads ≥2.5Kg(24.5N) Damp Heat Steady State IEC 60115-1 4.24 40±2°C,90-95% RH for 56 days, loaded with 0.1 times RCWV ±5.0%+0.05Ω Endurance at 70°C IEC 60115-1 4.25 70±2°C at RCWV (or Umax., whichever ±5.0%+0.05Ω Temperature Cycling IEC 60115-1 4.19 -55°C Room Temp. +155°C Room Temp. (5 cycles) ±1.0%+0.05Ω Resistance to Soldering Heat IEC 60115-1 4.18 260±3°C for 10±1 Sec., immersed to a point 3±0.5mm from the body ±1.0 %+0.05Ω Accidental Overload Test IEC 60115-1 4.26 4 times RCWV for 1 Min. No evidence of flaming or arcing Note: RCWV (Rated Continuous Working Voltage): The DC or AC (rms) continuous working voltage corresponding to the rated power is determined by the following formula: V=√(P X R) or max. working voltage whichever is less Where V=Continuous rated DC or AC (rms) working voltage (V) P=Rated power (W) R=Resistance value (Ω)
www.yageo.com Apr. 01, 2024 V.5 PULSE DIAGRAMS KNP100 Series: Pmax.: Maximum permissible peak pulse power ti: Pulse duration tp: Pulse repetition time KNP200 Series: Pmax.: Maximum permissible peak pulse power ti: Pulse duration tp: Pulse repetition time
www.yageo.com Apr. 01, 2024 V.5 KNP300 Series: Pmax.: Maximum permissible peak pulse power ti: Pulse duration tp: Pulse repetition time KNP400 Series: Pmax.: Maximum permissible peak pulse power ti: Pulse duration tp: Pulse repetition time
www.yageo.com Apr. 01, 2024 V.5 KNP500 Series: Pmax.: Maximum permissible peak pulse power ti: Pulse duration tp: Pulse repetition time KNP700 Series: Pmax.: Maximum permissible peak pulse power ti: Pulse duration tp: Pulse repetition time
www.yageo.com Apr. 01, 2024 V.5 KNP2WS Series: Pmax.: Maximum permissible peak pulse power ti: Pulse duration tp: Pulse repetition time KNP3WS Series: Pmax.: Maximum permissible peak pulse power ti: Pulse duration tp: Pulse repetition time
www.yageo.com Apr. 01, 2024 V.5 KNP3SS Series: Pmax.: Maximum permissible peak pulse power ti: Pulse duration tp: Pulse repetition time KNP5WS Series: Pmax.: Maximum permissible peak pulse power ti: Pulse duration tp: Pulse repetition time
www.yageo.com Apr. 01, 2024 V.5 KNP7WS Series: Pmax.: Maximum permissible peak pulse power ti: Pulse duration tp: Pulse repetition time
www.yageo.com Apr. 01, 2024 V.5 AXIAL / REEL TAPE SPECIFICATION Unit: mm Normal Miniature a A B1-B2 (Max.) S (spacing) T (max. deviation of spacing) KNP-25 KNP50S 6 ± 0.5 52.4 ± 1.5 1.2 5 1 mm per 10 spacing, 0.5 mm per 5 spacing 26.0 ± 1.5 1.0 KNP-50 KNP1WS 6 ± 0.5 52.4 ± 1.5 1.2 5 KNP100 KNP2WS KNP200 KNP300 KNP400 KNP3WS KNP500 KNP600 KNP7WS 6 ± 0.5 91.0 ± 1.5 1.5 10 KNP700 - 6 ± 0.5 91.0 ± 1.5 1.5 10
www.yageo.com Apr. 01, 2024 V.5 TAPE ON REEL PACKING TYPE Unit: mm/piece Normal Miniature Across Flange(A) B Quantity Per Reel KNP-25 KNP50S 66.5 75.5 5,000 KNP-50 KNP1WS 66.5 75.5 2,500 KNP100 KNP2WS KNP3SS 87 96 2,000 KNP200 KNP3WS 87 96 1,000 KNP300 KNP400 KNP5WS 87 96 1,000
www.yageo.com Apr. 01, 2024 V.5 TAPE ON BOX PACKING BULK PACKING Normal Miniature Piece/Per Inner Box Bag/Per Inner Box Piece Per Bag KNP-25 KNP50S 10,000 10 1,000 KNP-50 KNP1WS 5,000 5 1,000 KNP100 KNP2WS KNP3SS 2,000 4 500 KNP200 KNP3WS 1,000 2 500 KNP300 KNP400 KNP5WS 1,000 2 500 KNP500 KNP600 KNP7WS 500 10 50 KNP700 - 500 10 50 TYPE DIMENSIONS Unit: mm/piece Normal Miniature A B C Quantity Per Box KNP-25 KNP50S 48 102 255 5,000 KNP-25 KNP50S 81 104 260 5,000 KNP-50 KNP1WS 73 45 258 1,000 KNP100 KNP2WS KNP3SS 81 91 260 1,000 KNP100 KNP2WS KNP3SS 103 78 260 1,000 KNP200 KNP3WS 81 91 260 1,000 KNP200 KNP3WS 103 94 260 1,000 KNP300 KNP400 KNP5WS 81 91 260 500 KNP300 KNP400 KNP5WS 103 78 260 500 KNP500 KNP600 KNP7WS 116 79 255 250 KNP700 - 116 79 255 250
www.yageo.com Apr. 01, 2024 V.5 FORMING M TYPE MB TYPE TYPE DIMENSIONS Unit: mm Normal Miniature L ψD ψd P H1 H2 t KNP100 KNP2WS KNP300 TYPE DIMENSIONS Unit: mm Normal Miniature L ψD ψd P H KNP100 KNP2WS KNP300
www.yageo.com Apr. 01, 2024 V.5 MHA TYPE TYPE DIMENSIONS Unit: mm Normal Miniature L ψD ψd B H0 HI P P0 KNP-50 KNP1WS P1 P2 F W W0 W1 ΨD0 MHB TYPE TYPE DIMENSIONS Unit: mm Normal Miniature L ψD ψd B H H0 HI H2 H3 KNP200 KNP3WS P P0 PI P2 F W W0 W1 ΨD0
www.yageo.com Apr. 01, 2024 V.5 MHC TYPE TYPE DIMENSIONS Unit: mm Normal Miniature L ψD ψd B H HI P P0 KNP200 KNP3WS F TYPE FK TYPE FFK TYPE FKK TYPE TYPE DIMENSIONS Unit: mm Normal Miniature L ψD ψd P h H Max. hl HI Max. E Max. e
www.yageo.com Apr. 01, 2024 V.5 PN TYPE (Taping Pack) AV TYPE (Taping Pack) TYPE DIMENSIONS Unit: mm Normal Miniature H1 Max. Max. Max. KNP-25 KNP50S 13 21.5 8.5 KNP-50 KNP1WS 17 25.5 8.5 KNP100 KNP2WS KNP3SS 19 27.5 8.5 TYPE DIMENSIONS Unit: mm Normal Miniature H1 Max. Max. Max. KNP-25 KNP50S 11.5 20 8.5 KNP-50 KNP1WS 14.5 23 8.5 KNP100 KNP2WS KNP3SS 17.5 26 8.5 FT TYPE (Taping Pack) TYPE DIMENSIONS Unit: mm Normal Miniature H1 Max. Max. Max. KNP-25 KNP50S 10 18.5 8.5 KNP-50 KNP1WS 13 21.5 8.5 KNP100 KNP2WS KNP3SS 16 24.5 8.5
www.yageo.com Apr. 01, 2024 V.5 MARKING COLOR 1st BAND 2nd BAND 3rd BAND MULTIPLIER TOLERANCE BLACK 0 0 0 1Ω BROWN 1 1 1 10Ω ± 1% ( F ) RED 2 2 2 100Ω ± 2% ( G ) ORANGE 3 3 3 1KΩ YELLOW 4 4 4 10KΩ GREEN 5 5 5 100K BLUE 6 6 6 1MΩ VIOLET 7 7 7 10MΩ GREY 8 8 8 0.001Ω WHITE 9 9 9 0.0001Ω GOLD 0.1Ω ± 5 % ( J ) SILVER 0.01Ω 4-BAND-CODE ±2%, ±5% 5-BAND-CODE ±1%
www.yageo.com Apr. 01, 2024 V.5
REVISION HISTORY
REVISION DATE CHANGE NOTIFICATION DESCRIPTION Version 5 Apr.1, 2024 - - Added forming code description for part number Version 4 Mar. 27, 2024 - - Delete M type for KNP500&KNP600&KNP7WS Version 3 Nov. 10, 2023 - - Delete MB type for KNP500&KNP600&KNP7WS Version 2 Aug. 31, 2023 - - Revised LEGAL DISCLAIMER Version 1 Jun. 10, 2022 - Add suffix code to part number Version 0 Aug. 2, 2021 - - First issue of this specification “ Yageo reserves all the rights for revising the content of this datasheet without further notification, as long as the products itse lf are unchanged. Any product change will be announced by PCN.”
www.yageo.com Apr. 01, 2024 V.5 LEGAL DISCLAIMER YAGEO, its distributors and agents (collectively, “YAGEO”), hereby disclaims any and all liabilities for any errors, inaccuracies or incompleteness contained in any product related information, including but not limited to product specifications, datasheets, pictures and/or graphics. YAGEO may make changes, modifications and/or improvements to product related information at any time and without notice. YAGEO makes no representation, warranty, and/or guarantee about the fitness of its products for any particular purpose or the continuing production of any of its products. To the maximum extent permitted by law, YAGEO disclaims (i) any and all liability arising out of the application or use of any YAGEO product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for a particular purpose, non -infringement and merchantability. YAGEO products are designed for general purpose applications under normal operation and usage conditions. Please contact YAGEO for the applications listed below which require especially high reliability for the prevention of defects which might directly cause damage to the third party's life, body or property: Aerospace equipment (artificial satellite, rocket, etc.), Atomic energy-related equipment, Aviation equipment, Disaster prevention equipment, crime prevention equipment, Electric heating apparatus, burning equipment, Highly public information network equipment, data-processing equipment , Medical devices, Military equipment, Power generation control equipment, Safety equipment, Traffic signal equipment, Transportation equipment and Undersea equipment, or for any other application or use in which the failure of YAGEO products could result in personal injury or death, or serious property damage. Particularly YAGEO Corporation and its affiliates do not recommend the use of commercial or automotive grade products for high reliability applications or manned space flight. Information provided here is intended to indicate product specifications only. YAGEO reserves all the rights for revising this content without further notification, as long as products are unchanged. Any product change will be announced by PCN.