KE007A0S6R541-SR LINEAGEPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 13
Technical content
Features
Compliant to RoHS EU Directive 2002/95/EC (-Z versions) Compliant to RoHS EU Directive 2002/95/EC with lead solder exemption (non-Z versions) Delivers up to 7A output current High efficiency – 92% at 6.5VOUT, full load Small size and low profile: 33.0 mm x 22.9 mm x 8.5 mm (1.30 in x 0.9 in x 0.335 in) Industry standard DOSA footprint Surface Mount, Tape and Reel (-SR Suffix) Output voltage adjustment trim Remote On/Off Remote Sense No reverse current during output shutdown Over temperature protection (non-latching) Output overcurrent/overvoltage protection (non- latching) Wide operating temperature range (-40°C to 85°C) Meets the voltage isolation requirements for ETSI 300-132-2 and complies with and is licensed for Basic Insulation rating per EN60950-1 CE mark meets 73/23/EEC and 93/68/EEC directives§ (PENDING APPROVAL) UL* 60950-1Recognized, CSA† C22.2 No. 60950-1-03 Certified, and VDE‡ 0805:2001-12 (EN60950-1) Licensed ISO** 9001 and ISO 14001 certified manufacturing facilities
Description
The KE007 (Sixteenth-brick) series power modules are isolated dc-dc converters that operate over an input voltage range of 43.2 to 57.6Vdc and provide a single precisely regulated output. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. The modules exhibit high efficiency, typical efficiency of 92% for 6.5V/7A output. This open frame modules is available in surface-mount, tape and reeled (-SR) package. RoHS Compliant
March 26, 2008 KE007A0S6R5-SR (Sixteenth-Brick) Power Modules: 43.2 – 57.6Vdc Input; 6.5Vdc Output; 7.0A Output Current LINEAGE POWER 2 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage Continuous S6R5 V IN -0.3 60 Vdc Operating Ambient Temperature S6R5 T A -40 85 °C (see Thermal Considerations section) Storage Temperature S6R5 T stg -55 125 °C I/O Isolation voltage (100% factory Hi-Pot tested) S6R5 ⎯ ⎯ 1500 Vdc Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage S6R5 V IN 43.2 48 57.6 Vdc Maximum Input Current S6R5 I IN,max 1.7 2.0 Adc (VIN= VIN, min to VIN, max, IO=IO, max) Input No Load Current S6R5 I IN,No load 55 mA (VIN = VIN, nom, IO = 0, module enabled) Input Stand-by Current S6R5 I IN,stand-by 35 mA (VIN = VIN, nom, module disabled) Inrush Transient S6R5 I t 0.1 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1μH source impedance; VIN, min to VIN, max, IO= IOmax ; See Test configuration section) S6R5 30 mAp-p Input Ripple Rejection (120Hz) S6R5 50 60 100 dB EMC, EN55022 See EMC Considerations section CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a time-delay fuse with a maximum rating of 5 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
March 26, 2008 KE007A0S6R5-SR (Sixteenth-Brick) Power Modules: 43.2 – 57.6Vdc Input; 6.5Vdc Output; 7.0A Output Current LINEAGE POWER 3 Electrical Specifications (continued) Parameter Device Symbol Min Typ Max Unit Output Voltage Set-point S6R5 V O, set 6.40 6.50 6.60 V dc (VIN=VIN, min, IO=IO, max, TA=25°C) Output Voltage S6R5 V O 6.30 ⎯ 6.70 V dc (Over all operating input voltage, resistive load, and temperature conditions until end of life) Adjustment Range S6R5 V O,adj 5.20 7.15 V dc Selected by an external resistor Output Regulation Line (VIN=VIN, min to VIN, max) S6R5 ⎯ ⎯ 0.1 % V O, set Load (IO=IO, min to IO, max) S6R5 ⎯ ⎯ 0.1 % V O, set Temperature (Tref=TA, min to TA, max) S6R5 ⎯ ⎯ 1.0 % V O, set Output Ripple and Noise on nominal output (VIN=VIN, nom ,IO= IO, max , TA=TA, min to TA, max) RMS (5Hz to 20MHz bandwidth) ⎯ 25 50 mV rms Peak-to-Peak (5Hz to 20MHz bandwidth) S6R5 ⎯ 75 150 mV pk-pk External Capacitance S6R5 C O, max 0 ⎯ 10,000 μF Output Current S6R5 I O 0 ⎯ 7 A dc Output Current Limit Inception (Hiccup Mode ) (VO= 90% of VO, set) S6R5 IO, lim 8.05 8.4 8.75 Adc Output Short-Circuit Current (VO≤250mV) ( Hiccup Mode ) S6R5 I O, s/c ⎯ 3 ⎯ Arms Efficiency VIN= VIN, nom, TA=25°C IO=IO, max , VO= VO,set S6R5 η 92.0 % Switching Frequency S6R5 f sw 190 200 235 kHz Dynamic Load Response (dIo/dt=0.1A/μs; VIN = VIN, nom; TA=25°C) Load Change from Io= 50% to 75% or 25% to 50% of Io,max; Peak Deviation S6R5 V pk ⎯ 130 ⎯ mV Settling Time (Vo<10% peak deviation) S6R5 t s ⎯ 200 ⎯ μs (dIo/dt=1A/μs; VIN = VIN, nom; TA=25°C) Load Change from Io= 50% to 75% or 25% to 50% of Io,max; Peak Deviation S6R5 V pk ⎯ 130 ⎯ mV Settling Time (Vo<10% peak deviation) S6R5 t s ⎯ 200 ⎯ μs
March 26, 2008 KE007A0S6R5-SR (Sixteenth-Brick) Power Modules: 43.2 – 57.6Vdc Input; 6.5Vdc Output; 7.0A Output Current LINEAGE POWER 4 Isolation Specifications Parameter Device Symbol Min Typ Max Unit Isolation Capacitance S6R5 C iso ⎯ 1000 ⎯ pF Isolation Resistance S6R5 R iso 10 ⎯ ⎯ MΩ I/O Isolation Voltage S6R5 ⎯ ⎯ 1500 Vdc General Specifications Parameter Device Min Typ Max Unit Calculated MTBF Based upon Telcordia SR-332 Issue 1: Method 1 Case 3, (IO=80%IO, max, TA=40°C, Airflow = 200 lfm) S6R5 1,400,450 Hours Powered Random Vibration (VIN=VIN, min, IO=IO, max, TA=25°C, 0 to 5000Hz, 10Grms) S6R5 90 Minutes Weight S6R5 ⎯ 11.3 (0.4) ⎯ g (oz.) Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Device Symbol Min Typ Max Unit Remote On/Off Signal Interface (VIN=VIN, min to VIN, max ; open collector or equivalent, Signal referenced to VIN- terminal) Negative Logic: device code suffix “1” Logic Low = module On, Logic High = module Off Positive Logic: No device code suffix required Logic Low = module Off, Logic High = module On Logic Low - Remote On/Off Current S6R5 I on/off ⎯ ⎯ 1.0 mA Logic Low - On/Off Voltage S6R5 V on/off -0.7 ⎯ 1.2 V Logic High Voltage – (Typ = Open Collector) S6R5 V on/off ⎯ 5 V Logic High maximum allowable leakage current S6R5 I on/off ⎯ ⎯ 10 μA Turn-On Delay and Rise Times (IO=IO, max , VIN=VIN, nom, TA = 25 o Case 1: On/Off input is set to Logic Low (Module ON) and then input power is applied (delay from instant at which VIN = VIN, min until Vo=10% of Vo,set) S6R5 Tdelay ― 15 20 msec Case 2: Input power is applied for at least 1 second and then the On/Off input is set from OFF to ON (Tdelay = from instant at which VIN=VIN, min until VO = 10% of VO, set). S6R5 Tdelay ― 3 5 msec Output voltage Rise time (time for Vo to rise from 10% of Vo,set to 90% of Vo, set) S6R5 Trise ― 5 10 msec Output voltage overshoot – Startup ― 6.7 Vdc IO= IO, max; VIN=VIN, min to VIN, max, TA = 25 o C Remote Sense Range S6R5 0.65 V dc Output Overvoltage Protection S6R5 V O, limit 7.7 ⎯ 8.5 V Input Undervoltage Lockout Turn-on Threshold S6R5 V uv/on ⎯ 42 43 V Turn-off Threshold S6R5 V uv/off 39 40 ⎯ V Hysterisis S6R5 V hyst 2 ⎯ ⎯ V
Figure 17. Reflow Profile for Tin/Lead (Sn/Pb) Figure 18. Time Limit Curve Above 205oC for suggested Pb-free solder paste is Sn/Ag/Cu (SAC). Sn/Ag/Cu solder is shown in Fig. 19. The KE007 modules have a MSL rating of 1. varies according to the MSL rating (see J-STD-033A).
15 Seconds
60 Seconds
Figure 19. Recommended linear reflow profile
March 26, 2008 KE007A0S6R5-SR (Sixteenth-Brick) Power Modules: 43.2 – 57.6Vdc Input; 6.5Vdc Output; 7.0A Output Current LINEAGE POWER 11 Mechanical Outline for Surface Mount Module Dimensions are in millimeters and [inches]. Top View Side View Bottom View PIN FUNCTION
1 V IN(+)
2 On/Off
3 V IN(-)
4 V o(-)
5 Sense (-)
6 Trim
7 Sense (+)
8 Vo (+)
March 26, 2008 KE007A0S6R5-SR (Sixteenth-Brick) Power Modules: 43.2 – 57.6Vdc Input; 6.5Vdc Output; 7.0A Output Current LINEAGE POWER 12 Recommended Pad Layout Dimensions are in millimeters and [inches]. SMT Recommended Pad Layout (Component Side View) Packaging Details Tape Dimensions Dimensions are in millimeters and [inches]. The Sixteenth-brick SMT versions are supplied in tape & reel as standard. Details of tape dimensions are shown above. Modules are shipped in quantities of 140 modules per reel.
March 26, 2008 KE007A0S6R5-SR (Sixteenth-Brick) Power Modules: 43.2 – 57.6Vdc Input; 6.5Vdc Output; 7.0A Output Current Document No: DS06-118 ver. 1.01 PDF name: ke007_ds.pdf
Ordering Information
Please contact your Lineage Power Sales Representative for pricing, availability and optional features. Table 1. Device Code Table 2. Device Options
3000 Skyline Drive, Mesquite, TX 75149, USA
application. No rights under any patent accompany the sale of any such product(s) or information. © 2008 Lineage Power Corporation, (Mesquite, Texas) All International Rights Reserved.