KBU10 JUXING | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

GLASS PASSIVATED BRIDGE RECTIFIERS REVERSE VOLTAGE - 50 to 1000Volts FORWARD CURRENT - 10/15/25/35Amperes

FEATURES

Surge overload rating -200~300 amperes peak Ideal for printed circuit board Reliable low cost construction utilizing molded plastic technique Plastic material has UL flammability classification 94V-0 Mounting postition:Any Mounting torgue:5 In.Ib.Max Weight: 0.25ounces ,7.0grams MAXIMUM RATINGS AND ELECTRICALCHARACTERISTIC S Rating at 25℃ ambient temperature unless otherwise specified. Single phase, half wave ,60Hz, resistive or inductive load. For capacitive load, derate current by 20% KBU KBU KBU KBU KBU KBU KBU 10005 1001 1002 1004 1006 1008 1010 15005 1501 1502 1504 1506 1508 1510 25005 2501 2502 2504 2506 2508 2510 35005 3501 3502 3504 3506 3508 3510 Maximum Recurrent Peak Reverse Voltage V RRM 50 100 200 400 600 800 1000 V Maximum RMS Voltage V RMS 35 70 140 280 420 560 700 V Maximum DC Blocking Voltage V DC 50 100 200 400 600 800 1000 V Maximum Average Forward (with heatsink Note 2) Rectified Current @ T C =100℃ (without heatsink) Peak Forward Surage Current 8.3ms Single Half Sine-Wave Super Imposed on Rated Load (JEDEC Method) Maximum Forward Voltage at 5.0/7.5/12.5/17.5A DC V F V Maximum DC Reverse Current @ T J =25℃ at Rated DC Blocking Voltage @ T J =125℃ Operating Temperature Range T J Storage Temperature Range T STG NOTES: 1.Measured at 1.0MHz and applied reverse voltage of 4.0V DC. 2.Device mounted on 100mm*100mm*1.6mm cu plate heatsink. A 1.1 uA 500 UNIT I (AV) A CHARACTERISTICS SYMBOL I FSM I R -55 to +150 -55 to +150 KBU 10 15 25 35 200 250 300 300 KBU KBU KBU 3.0 3.2 3.6 4.2 7 5 - ; BRIDGE RECTIFIERS http://www.trr-jx.comversion: 02 Dimensions in inches and (milimeters) .935(23.7) .895(22.7) .600(16.8) .700(17.8) .300 (7.5) .780(19.8) .740(18.8) (20.0) 0.787MIN. .048(1.2)DIA. .045(1.15)TYP. .071(1.8) .180(4.6) .256(6.5) .236(6.0) .15 X23L (3.8 X5.7L) HOLE THRU (23.0) 0.906 MIN.

FIG.2– TYPICAL FORWARD CHARACTERISTICS INSTANTANEOUS FORWARD CURRENT (AMPERES) INSTANTANEOUS FORWARD VOLTAGE, VOLTS 0.1 1.0 0.01 100 KBU25 KBU15 KBU 35 KBU10 FIG.3– TYPICAL REVERSE CHARACTERISTICS PERCENT OF RATED PEAK REVERSE VOLTAGE INSTANTANEOUS REVERSE CURRENT MICROAMPERES T J = 25 0.01 0.1 1.0 140120100806040200 TEMPERATURE (°C) FIG. 4 – DERATING CURVE OUTPUT RECTIFIED CURRENT AVERAGE FORWARD OUTPUT CURRENT AMPERES 100 150 KBU35 KBU25 KBU15 KBU10 FIG. 1 – MAXIMUM FORWARD SURGE CURRENT PEAK FORWARD SURGE CURRENT AMPERES NUMBER OF CYCLES AT 60Hz KBU25/35 KBU15 KBU10 200 300 250 10 100 150 100 350 http://www.trr-jx.comversion: 02 Characteristic Curves A =25 ℃ unless otherwise noted) KBU10/15/25/35 7 5 - ; BRIDGE RECTIFIERS