K50U BANNER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
The Sure Cross® K50U sensor works in a variety of environments to provide a measurement of the distance between the target and the sensor. It is designed for plug-and-play use with the Wireless Q45U Node (or any other Banner 1-wire serial node), creating a cost-effective and easy-to-use solution for monitoring remote or mobile tanks and totes. Benefits
- Monitor wirelessly to avoid long cable runs
- Threaded housing for easy installation
- Easily monitor remote and mobile tanks and totes
- Completely wireless solution with 2+ year battery life at default sample rates
- Provides a distance measurement from the target to the sensor
- Built-in temperature compensation
- Rugged design for demanding sensing environments; rated IEC IP67, NEMA 6P
- Connects using a 1-wire serial interface
- Designed to work with FlexPower 1-Wire Serial Interface Node models DX80N9X1S-P6 and DX80N2X1S-P6, the 10 to 30 V dc powered 1-Wire Serial Interface Node models DX80N9X6S-P6 and DX80N2X6S-P6, MultiHop M-H6 and M-H6L radios, and Wireless Q45 Sensor Nodes DX80N2Q45U and DX80N9Q45U WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Models Model Range and Frequency Supply Voltage I/O K50UX1ARA Range: 100 mm to 1 m (3.94 in to 39.4 in) Freq: 224 kHz 3.6 to 5.5 V dc or 10 to 30 V dc Distance to target using a 1-wire serial interface K50UX1CRA Range: 300 mm to 3 m (11.8 in to 118 in) Freq: 114 kHz Overview The K50U is an easy-to-use ultrasonic sensor with extended range and built-in temperature compensation. This sensor is designed to interface with a Node with 1-Wire Serial Interface. To install the sensor to either the serial Node or a cable, follow these instructions: 1. Align the notch in the Node’s or cable’s female connector with the key in the sensor’s male connector. 2. Gently slide the sensor end into the Node’s or cable’s connector. 3. Rotate the Node’s or cable’s threaded nut to tighten the sensor down. DO NOT attempt to rotate the sensor after it is connected to the Node’s serial port or the cable end, this will damage the sensor. Indicator LEDs communicate the status of the sensor. The flashing green Power LED indicates the sensor is in Run Mode (the sensor’s normal operating condition). Configure this sensor using the Sure Cross® Sensor Configuration Tool (instruction manual 170002) and adapter cable BWA- USB1WIRE-001 (datasheet 170020). Principles of Operation Ultrasonic sensors emit one or multiple pulses of ultrasonic energy, which travel through the air at the speed of sound. A portion of this energy reflects off the target and travels back to the sensor. The sensor measures the total time required for the energy to reach the target and return to the sensor. The distance to the object is then calculated using the following formula: D = ct ÷ 2 Sure Cross® U-GAGE K50U Ultrasonic Sensor Original Document 191599 Rev. F
2 May 2018
D = distance from the sensor to the target c = speed of sound in air t = transit time for the ultrasonic pulse To improve accuracy, an ultrasonic sensor may average the results of several pulses before outputting a new value. Temperature Effects The speed of sound is dependent upon the composition, pressure and temperature of the gas in which it is traveling. For most ultrasonic applications, the composition and pressure of the gas are relatively fixed, while the temperature may fluctuate. In air, the speed of sound varies with temperature according to the following approximation: In metric units: C m/s = 2 0 √ 2 73 + T C In English units: ft/s = 49 √ 460 + T FC Cm/s = speed of sound in meters per second Cft/s = speed of sound in feet per second TC = temperature in °C TF = temperature in °F Temperature Compensation Changes in air temperature affect the speed of sound, which in turn affects the total time for the echo measured by the sensor. An increase in air temperature shifts both sensing window limits closer to the sensor. Conversely, a decrease in air temperature shifts both limits farther away from the sensor. This shift is approximately 3.5% of the limit distance for a 20° C change in temperature. The K50U series ultrasonic sensors are temperature compensated, to reduce sensor errors from temperature by about 90%. Exposure to direct sunlight can affect the sensor’s ability to accurately compensate for changes in temperature. LED Indicators Signal LED (red) Power LED (green) Power is Off Off Sensor is operating normally (power is on, sensor is in Run mode) Flashing Serial Communications Transmit/Receive Intermittent Flashing Error Continuous Flashing Reserved Off Self-Diagnostic Error Mode—In the unlikely event of a microprocessor memory error, the Signal LED continuously flashes. If this occurs, the setup parameters have been lost and the sensor may be corrupt. Contact your Banner representative for further information. Sensor Configuration Tool The Sensor Configuration Tool offers an easy way to manage sensor parameters, retrieve data, and visually show sensor data from a number of different sensors. The Sensor Configuration Tool software runs on any Windows machine and uses an adapter cable to connect the sensor to your computer. Download the most recent version of the Sensor Configuration Tool from Banner Engineering's website: www.bannerengineering.com/wireless. The Sensor Configuration Tool currently supports the following sensors: Sensor Type Model USB Adapter Cable Temperature and Humidity M12FTH3Q and M12FT3Q Model BWA-HW-006: USB-to-RS-485 adapter cable OR Model BWA-UCT-900: USB to RS-485 adapter cable M12FTH4Q and M12FT4Q Model BWA-USB1WIRE-001: USB-to-RS-232 1-Wire adapter cable Vibration and Temperature QM42VT1 Model BWA-USB1WIRE-001: USB-to-RS-232 1-Wire adapter cable QM42VT2 Model BWA-HW-006: USB-to-RS-485 adapter cable OR Model BWA-UCT-900: USB to RS-485 adapter cable OR When updating the firmware, you must use one of the two USB to RS-485 adapter cables plus a splitter pigtail cable p/n 83265 Sure Cross® U-GAGE K50U Ultrasonic Sensor 2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 191599 Rev. F
Sensor Type Model USB Adapter Cable GPS GPS50M Model BWA-HW-006: USB-to-RS-485 adapter cable AND a field-wireable M12/Euro-style connector or connecter with pigtail OR Model BWA-UCT-900: USB to RS-485 adapter cable AND a field-wireable M12/Euro-style connector or connecter with pigtail U-GAGE K50U Ultrasonic K50UX1CRA Model BWA-USB1WIRE-001: USB-to-RS-232 1-Wire adapter cable K50UX2CRA Model BWA-HW-006: USB-to-RS-485 adapter cable OR Model BWA-UCT-900: USB to RS-485 adapter cable K50UX1ARA Model BWA-USB1WIRE-001: USB-to-RS-232 1-Wire adapter cable K50UX2ARA Model BWA-HW-006: USB-to-RS-485 adapter cable OR Model BWA-UCT-900: USB to RS-485 adapter cable Wiring This sensor is designed to be plugged directly into compatible Nodes. The Node powers the sensor and periodically requests data using the 1-wire serial interface. Refer to the Class I Division 2 control drawings (p/n 143086) for wiring specifications or limitations. 5-pin M12/Euro-style Connector (Male) Pin Wire Color Sensor Connection 1 Brown Power IN (+), 3.6 to 5.5 V dc
2 White 1-Wire serial device select (sinking input to sensing device)
3 Blue Ground (-)
4 Black Not used/reserved
5 Gray 1-Wire serial communications
The temperature = (Modbus register value) ÷ 20. The distance (in) = (Modbus register value) ÷ 100. Sensor Register Output Type I/O Range Holding Register Representation Min Max Min (Dec) Max (Dec)
1 Distance (mm) 0 65535 0 65535
2 Temp °C –1638.4 1638.3 –32768 32767 3 Temp °F –1638.4 1638.3 –32768 32767 4 Distance (in) 0 655.35 0 65535 Distance readings below 250 mm (9.84 in) for model K50UX1CRA and below 75 mm (2.95 in) for model K50UX1ARA result in a register value of 0. If no reflection is received because the target is too far away, the register value is an error value of 65535. Specifications Supply Voltage 3.6 to 5.5 V dc or 10 to 30 V dc Current Default sensing: 180 µA Disabled sensing: 40 µA Active comms: 3.3 mA Construction Housing: PBT polyester Transducer: epoxy/ceramic composite Indicators Two LEDs Connection Integral 5-pin M12/Euro-style male quick disconnect Sure Cross® U-GAGE K50U Ultrasonic Sensor P/N 191599 Rev. F www.bannerengineering.com - Tel: +1-763-544-3164 3
Sensing range: 300 mm to 3 m (11.8 in to 118 in) Ultrasonic frequency: 114 kHz Temperature effect: 0.02% of distance/°C Resolution: 0.1% of distance (1.5 mm minimum) K50UX1ARA Performance Sensing range: 100 mm to 1 m (3.94 in to 39.4 in) Ultrasonic frequency: 224 kHz Temperature effect: 0.02% of distance/°C Resolution: 0.1% of distance (1.5 mm minimum) Communication Hardware 1-wire serial interface Baud Rates: 9.6k, 19.2k (default), or 38.4k Data Format: 8 data bits, No parity (default), even parity, or odd parity 1 stop bit Discrete Inputs One Sinking Rating: 3 mA max current at 30 V dc ON Condition: Less than 0.7 V OFF Condition: Greater than 2 V or open Discrete Outputs Discrete Outputs. One NMOS Sinking (Not used) Discrete Output Rating: Less than 10 mA maximum current at 30 V; ON- State Saturation: Less than 0.7 V at 20 mA Discrete Output ON Condition. Less than 0.7 V Discrete Output OFF Condition. Open Communication Protocol Sure Cross DX80 Sensor Node 1-Wire Serial Interface Communications Line Level Receive ON: Greater than 2 V Level Receive OFF: Less than 0.7 V Level Transmit ON: 2.7 to 3 V Level Transmit OFF: 0 V (pulldown resistor of 10 kOhm) Compatible Nodes
900 MHz Models
2.4 GHz Models
Leakproof design, rated IEC IP67 (NEMA 6) Operating Conditions 95% at +50 °C maximum relative humidity (non-condensing) Vibration and Mechanical Shock All models meet MIL-STD-202F, Method 201A (Vibration: 10 Hz to 60 Hz maximum, 0.06 inch (1.52 mm) double amplitude, 10G maximum acceleration) requirements. Also meets IEC 60947-5-2 (Shock: 30G 11 ms duration, half sine wave) requirements. Certifications Dimensions 59.5 mm [2.34”] 20 mm [0.79] 27.5 mm [1.08”] M30 x 1.5 50 mm [1.97”] 19 mm [0.75”] 1 1/4-11.5 NPT All measurements are listed in millimeters [inches], unless noted otherwise. 1 Operating the devices at the maximum operating conditions for extended periods can shorten the life of the device. Sure Cross® U-GAGE K50U Ultrasonic Sensor 4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 191599 Rev. F
1 Meter Models
With Plate Target (Typical) With Rod Target (Typical) Maximum Target Rotation Angle 0 200 mm (8.0 in) 400 mm (16.0 in) 600 mm (24.0 in) 800 mm (32.0 in) 1000 mm (40.0 in) 100 100 150 150 200 200 2.0 in 2.0 in 4.0 in 4.0 in 6.0 in 6.0 in 8.0 in 8.0 in DISTANCE 100 x 100 mm 10 x 10 mm WIDTH (mm) 100 100 150 150 200 200 0 200 mm (8.0 in) 400 mm (16.0 in) 600 mm (24.0 in) 800 mm (32.0 in) 1000 mm (40.0 in) 2.0 in 2.0 in 4.0 in 4.0 in 6.0 in 6.0 in 8.0 in 8.0 in 25 mm Rod 10 mm Rod DISTANCE WIDTH (mm) Target Rotation(Degrees) Distance
3 Meter Models
With Plate Target (Typical) With Rod Target (Typical) Maximum Target Rotation Angle 400 mm 300 mm 200 mm 100 mm 0 600 mm(24") 1200 mm(48") 1800 mm(72") 2400 mm(96") 3000 mm(120") 100 mm 200 mm 300 mm 400 mm 16" 12" 12" 16" DISTANCE WIDTH 100 x 100 mm 400 mm 300 mm 200 mm 100 mm 0 600 mm (24") 1200 mm (48") 1800 mm (72") 2400 mm (96") 3000 mm (120") DISTANCE 100 mm 200 mm 300 mm 400 mm 16" 12" 12" 16" WIDTH 25 mm Rod 10 mm Rod 0 500 mm(20") 1000 mm(40") 1500 mm(60") 2000 mm(80") 2500 mm(100") 3000 mm(120") TARGET ROTATION(DEGREES) DISTANCE Accessories Brackets BWA-BK-004
- Mounts both the K50U Ultrasonic sensor and a Wireless Q45U Node or DX80 Node 181 Ø30 BWA-BK-006
- Mounts both the K50U Ultrasonic sensor and a Wireless Q45U Node 97 Ø33.54X Ø5.2 4X Ø6 Euro-Style Cordsets - Double Ended When using the FlexPower Node with integrated battery, use a double ended cordset. When using a FlexPower Node with external power supply, use a single ended cordset. If using the communication lines, the cable length cannot exceed 3 meters (10 ft). Sure Cross® U-GAGE K50U Ultrasonic Sensor P/N 191599 Rev. F www.bannerengineering.com - Tel: +1-763-544-3164 5
5-Pin Threaded M12/Euro-Style Cordsets—Double Ended and Less Than 3 m Long Model Length Style Dimensions Pinout DEE2R-51D 0.31 m (1 ft) Female Straight/ Male Straight 40 Typ. ø 14.5 M12 x 1 44 Typ. ø 14.5 M12 x 1 Male Female 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Green/Yellow DEE2R-53D 0.91 m (3 ft) DEE2R-58D 2.44 m (8 ft) Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. Sure Cross® U-GAGE K50U Ultrasonic Sensor © Banner Engineering Corp. All rights reserved