K50_V14 BANNER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 8

Technical content

50 mm IO-Link Controlled Multicolor RGB Devices (Touch Button, Push Button, and Optical Sensor)

  • IO-Link gives full access to color, flashing, rotating, and dimming settings as well as advanced animations such as dynamic sequence mode and LED control
  • Output settings, including on and off delays, output function, and output state are also available with IO-Link
  • 18 V DC to 30 V DC operation Standard Model: Touch Button Compact Model: Touch Button Optical Sensor Push Button WARNING:
  • Do not use this device for personnel protection
  • Using this device for personnel protection could result in serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A device failure or malfunction can cause either an energized (on) or de-energized (off) output condition. Models Touch Button Models
  • Excellent immunity to false triggering by water spray, oils, and other foreign materials Rated IEC IP67 and IP69K per DIN 40050-9
  • Vibration feedback models available for an unmistakable touch confirmation
  • Can be actuated with bare hands or gloves; adjustable sensitivity
  • Compact models available for lower profile applications
  • Models constructed from FDA-grade materials available Family K50 P = Pro Q** = 4-pin integral M12/Euro-style quick disconnect QP = 150 mm (5.9 in) PVC cable with 4-pin M12/Euro-style quick disconnect QP Connector * Not available in FDA-grade material or with vibration feedback ** Not available in FDA-grade material Models with a quick disconnect require a mating cordset Activation Method T = Touch TF = Touch, FDA-grade Housing C = Compact* Blank = Standard Dome Control K = IO-Link P T C K Style TV = Touch, Vibration Feedback TFV = Touch, FDA-grade, Vibration Feedback To order the touch button with an alternate laser marking than the touch icon, see Standard Laser Marking Options on p. 7. Push Button and Optical Sensor Models
  • Fixed-field models are immune to ambient light, EMI and RFI interference
  • Fixed-field models rated IEC IP67 and IP69K per DIN 40050-9 Push Button models rated IEC IP65 Family K50 P = Pro Q = 4-pin integral M12/Euro-style quick disconnect QP = 150 mm (5.9 in) PVC cable with 4-pin integral M12/Euro-style quick disconnect Q Connector Models with a quick disconnect require a mating cordset *Cutoff distance will vary from specified range based on target and tolerances. Activation Method FF50 = 50 mm Fixed Field* FF100 = 100 mm Fixed Field* Control K = IO-Link P FF50 K Style FF200 = 200 mm Fixed Field* PB = Push Button QPMA = 150 mm (5.9 in) PUR cable with 4-pin integral M12/Euro-style quick disconnect K50 Pro Devices with IO-Link Original Document 208737 Rev. E

3 April 2020

18–30 V DC IO-Link Communication Not used Key 1 = Brown 2 = White 3 = Blue 4 = Black IO-Link® IO-Link® is a point-to-point communication link between a master device and a sensor and/or light. It can be used to automatically parameterize sensors or lights and to transmit process data. For the latest IO-Link protocol and specifications, please visit www.io-link.com. For the latest IODD files, please refer to the Banner Engineering Corp website at: www.bannerengineering.com. IO-Link Process Data In (Device to Master) Use process data to read the device output state. When the device is in Four State Full Logic mode, use process data to read the device logic state in addition to the output state. Name Description Output State Output state follows touch, optical sensor, or push button input Device State Current state (State 1, State 2, State 3, State 4). Only available with Operation Mode set to Four State Full Logic or Multicolor IO-Link Process Data Out (Master to Device) Use process data out to define device states. Use parameter data to define device modes, states, touch settings, output settings, vibration feedback, and custom colors. Advanced Mode Use process data to control delays, color, intensity, flash, and other animation types. Process data is also used to control the sequence value dynamically. Use parameter data to create custom colors, intensity, speeds, and to define output and touch settings. Four State Full Logic Mode Use process data to define the Job Input state and to read the touch, optical sensor, or push button state and device state (State 1, State 2, State 3, State 4). See below for more information about how to achieve legacy logic types (C, D, E, and H). Use parameter data to change color, intensity, flash, speed, select animation type, and define output settings. Multicolor Mode Use process data to activate the defined device state. Use parameter data to define output settings, control delays, color, intensity, flash, and other animation types for State 1, State 2, State 3, and State 4. Definitions for device states in Advanced Mode, Four State Full Logic Mode, and Multicolor Mode Name Description Animation Type Off Indicator is off Steady Color 1 is solid on at defined intensity Flash Color 1 flashes at defined speed, color intensity, and pattern Two Color Flash Color 1 and Color 2 flash alternately at defined speed, color intensities, and pattern 50/50 Color 1 is displayed on 50% of the indicator and Color 2 is displayed on the other 50% of the indicator at the defined color intensities 50/50 Rotate Color 1 is displayed on 50% of the indicator and Color 2 is displayed on the other 50% of the indicator while rotating at the defined speed, color intensities, and rotational direction Chase Color 1 is displayed as a single spot against the background of Color 2 while rotating at the defined speed, color intensities, and rotational direction Intensity Sweep Color 1 repeatedly increases and decreases intensity between 0% to 100% at defined speed and color intensity Color Sweep Color 1 and Color 2 transition alternately at defined speed and color intensities Sequence Color 1 increments against the background of Color 2 at defined Dynamic or Static Sequence Value (Advanced mode and other modes respectively) Animation Direction Defines the direction of rotation for the 50/50 rotate, chase, and sequence animations (CW or CCW) Animation Pattern Defines the flash pattern for flash and two color flash animations (normal, strobe, three pulse, SOS, or random); also defines the pattern of the vibration feedback Animation Speed Defines the animation speed (slow, medium, fast, or custom); also defines the speed of the vibration feedback pattern Vibration Feedback Defines the type of vibration response when the button is touched (Off, On, Animation Pattern) (Touch models with vibration only) Off Delay Type Defines if the Off Delay should be measured from when the conditions for the State began (Leading Edge) or from when the conditions ended (Trailing Edge) Off Delay (ms) The duration of the animation Off Delay. Leading Edge Off Delays can be used to ensure the animation is active for at least a minimum amount of time. K50 Pro Devices with IO-Link 2 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 208737 Rev. E

Definitions for device states in Advanced Mode, Four State Full Logic Mode, and Multicolor Mode Name Description Dynamic/Static Sequence Value Defines the span of Color 1 in the Sequence animation [0-255]. 0 means no portion of the animation will be Color 1, and it increases in a circular manner to 255 which indicates the full circumference will be Color 1. In Advanced Mode, this is in process data and is called Dynamic Sequence Value. In the other modes, this is in parameter data and is called Static Sequence Value. Sequence Shift Shifts the beginning of the sequence animation to the specified LED (LED1 at 12 o'clock continuing in the direction indicated by the Animation Direction parameter Color 1 Defines Color 1 of defined animation Color 1 Intensity Defines the intensity of Color 1 in the animation (high, medium, low, off, or custom) Color 2 Defines Color 2 of defined animation Color 2 Intensity Defines the intensity of Color 2 in the animation (high, medium, low, off, or custom) Four State Full Logic Mode State Descriptions Use process data job input and the touch button, optical sensor, or push button input to dictate which one of these states the device should be in. Use parameter data to define the state characteristics. State 1: Process Data job input off and touch, optical sensor, or push button inactive State 2: Process Data job input on and touch, optical sensor, or push button inactive State 3: Process Data job input off and touch, optical sensor, or push button active State 4: Process Data job input on and touch, optical sensor, or push button active Four State Full Logic Not Actuated Actuated No Input State 1 State 3 Job Input State 2 State 4 Legacy Logic Definitions (Four State Full Logic) C Logic State 1 is Off. State 2 is Color 1/Job Input. State 3 is Color 2/Acknowledge. State 4 is defined the same as State 3 D Logic State 1 is Off. State 2 is Color 1/Job Input. State 3 is Off. State 4 is defined the same as State 2 E Logic State 1 is Off. State 2 is Color 1/Job Input. State 3 is Color 2/Mispick. State 4 is defined the same as State 2 H Logic State 1 is power, defined as Color 1. State 2 is defined the same as State 1. State 3 is Color 2/ Sense. State 4 is defined the same as State 3 LED Control Mode Use process data to define the color and intensity of each individual LED. Use parameter data to define customer colors and intensities. LED1 is oriented at the 12 o'clock position continuing clockwise through LED8 near 11 o'clock position. Name Description LED 1 Color…LED 8 Color Defines the color of the designated LED. LED 1 Intensity…LED 8 Intensity Defines the intensity of the designated LED [Values: 0-10] Vibration Feedback Defines the type of vibration response when the button is touched (Off, On, Pattern) (Touch models with vibration only) Vibration Pattern Defines the pattern of the vibration feedback (normal, strobe, three pulse, SOS, or random) (Touch models with vibration only) Vibration Speed Defines the speed of the vibration feedback pattern (slow, medium, fast, or custom) (Touch models with vibration only) Demo Mode Cycles through color spectrum, 50/50 rotate, intensity sweep, and sequence mode. Touch, optical sensor, or push button speeds cycle rate up or down (can be either Momentary or Latching). Touch, optical sensor, or push button initiates state showing individually colored LEDs. When set to demo mode, the device will cycle through the defined sequence when power is applied regardless of its connection to an IO-Link master. Touch Settings Use Parameter Data to define the following settings. Setting Description Touch Sensitivity Defines the sensitivity of the touch button as either Standard, High or Low. Low sensitivity resists false activation. High sensitivity can be used for improved touch response (Touch models only) Function Latching or Momentary Options. Momentary function toggles output on only during a touch, optical sensor, or push button input. Latching function toggles output on or off for each touch, optical sensor, or push button input Mute Enable Turning on mute disables the touch, optical sensor, or push button input On Delay (ms) Length of time the button needs to be pressed or the sensor needs to be blocked to trigger an active state. 0-60,000 ms Output Settings Use Parameter Data to define the following settings. Setting Description Output State Normally Open or Normally Closed. Normally Open turns the output on with a touch, optical sensor, or push button input. Normally Closed turns the output off with a touch, optical sensor, or push button input Off Delay Type Leading Edge or Trailing Edge. Leading Edge delays will begin once a touch, optical sensor, or push button has been sensed. Trailing edge delays will begin once the touch, optical sensor, or push button has been released K50 Pro Devices with IO-Link P/N 208737 Rev. E www.bannerengineering.com - Tel: + 1 888 373 6767 3

Off Delay (ms) Length of time before the output state returns to a touch, optical sensor, or push button inactive state after the button has been released or sensor has been unblocked. 0-60,000 ms Specifications Supply Voltage

18 V DC to 30 V DC

132 mA maximum current at 18 V DC Touch Models: 93 mA typical at 24 V DC Optical Models: 75 mA typical at 24 V DC Push Button Models: 65 mA typical at 24 V DC Supply Protection Circuitry Protected against reverse polarity and transient voltages Touch Dwell Time If touch dwells for longer than 60 seconds, the output will revert to the untouched state Vibration Feedback Characteristics Max Total On-Time Per Touch: 3 seconds Mechanical Life: 500,000 cycles For all touch conditions, the default Vibration Feedback is On and the type of vibration feedback is Steady Touch Response Time Input Response: 5 ms minimum Touch Response: 300 ms maximum (Standard Sensitivity touch response) Optical Sensor Emitter LED Infrared, 870 nm Operating Conditions Humidity: 90% at +50 °C maximum relative humidity (non-condensing) Storage: –40 °C to +70 °C (–40 °F to +158 °F) Environmental Rating Touch and Optical Models: IEC IP67, IP69K per DIN 40050-9 Push Button Models: IEC IP65 Mounting M30 × 1.5 threaded base, maximum torque 4.5 N·m (40 in·lbf) Construction Standard Model Base, Dome, and Nut: Polycarbonate FDA Model Base, Dome, and Nut: FDA-grade copolyester Push Button: Thermoplastic Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 30G 11 ms duration, half sine wave) IO-Link Interface Supports Smart Sensor Profile: No Baud Rate: 38400 bps (COM2) Process Data In: 16 bits (2 bytes) Process Data Out: 80 bits (10 bytes) IODD Files: Provides all programming options, plus additional functionality Connections Integral 4-pin M12/Euro-style quick disconnect or 150 mm (5.9 inch) PVC cable with a M12/Euro-style quick disconnect, depending on model Models with a quick disconnect require a mating cordset Certifications Default Indicator Characteristics Color Dominant Wavelength (nm) or Color Temperature (CCT) Color Coordinates2 Lumen Output for Touch Models (Typical at 25 °C)3x y Green 522 0.154 0.700 16.5 Red 620 0.689 0.309 8.3 Yellow 576 0.477 0.493 23.8 Blue 466 0.140 0.054 4.6 White 5700K 0.328 0.337 25.1 Cyan 493 0.170 0.340 18.4 Magenta – 0.379 0.172 11.1 Amber 589 0.556 0.420 15.7 Rose – 0.515 0.220 9.1 Lime Green 562 0.388 0.561 21.4 Sky Blue 486 0.155 0.247 19.5 Orange 599 0.616 0.370 12.1 Violet – 0.217 0.089 9.7 Spring Green 508 0.177 0.536 17.0 Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. Standard Models: Touch Button Ø50 mm [1.97”] 66 mm [2.6”] 55 mm [2.17”] 35 mm [1.38”] M30 x 1.5 M12 x 1 Compact Models: Touch Button 17 mm [0.67”] 37.0 mm [1.46”] 48.0 mm [1.89”] Ø50 mm [1.97”] 1 QP models must be installed to protect the cable and cable entrance from high-pressure spray to meet IP69K. 2 Refer to the CIE 1931 (x,y) Chromaticity Diagram to show equivalent color with indicated color coordinates. Actual coordinates may differ ± 5%. 3 Values shown apply to touch dome models only. Lumen output for compact models is 20% lower, optical sensor models is 14% lower, and push button models is 10% lower. K50 Pro Devices with IO-Link 4 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 208737 Rev. E

Ø50.0 mm [1.97”] M30 × 1.5 M12 × 1 36.3 mm 56.3 mm 67.3 mm [1.43”] [2.22”] [2.65”] Accessories Cordsets 4-Pin Threaded M12/Euro-Style Cordsets—Double Ended Model Length Style Dimensions Pinout MQDEC-401SS 0.31 m (1 ft) Male Straight/Female Straight 40 Typ. [1.58"] ø 14.5 [0.57"] M12 x 1 44 Typ. [1.73"] ø 14.5 [0.57"] M12 x 1 Female Male 1 = Brown 2 = White 3 = Blue 4 = Black MQDEC-403SS 0.91 m (3 ft) MQDEC-406SS 1.83 m (6 ft) MQDEC-412SS 3.66 m (12 ft) MQDEC-420SS 6.10 m (20 ft) MQDEC-430SS 9.14 m (30 ft) MQDEC-450SS 15.2 m (50 ft) 4-Pin Threaded M12/Euro-Style Cordsets—Double Ended, Oil Resistant Model Length Style Dimensions Pinout MQDEC-401SS-PUR 0.3 m (1 ft) Male Straight/Female Straight 40 Typ. [1.58"] ø 14.5 [0.57"] M12 x 1 44 Typ. [1.73"] ø 14.5 [0.57"] M12 x 1 Female Male 1 = Brown 2 = White 3 = Blue 4 = Black MQDEC-403SS-PUR 1 m (3.28 ft) MQDEC-406SS-PUR 2 m (6.56 ft) MQDEC-415SS-PUR 5 m (16.40 ft) MQDEC-430SS-PUR 10 m (32.81 ft) K50 Pro Devices with IO-Link P/N 208737 Rev. E www.bannerengineering.com - Tel: + 1 888 373 6767 5

4-Pin Threaded M12/Euro-Style Cordsets—Double Ended, Washdown, Stainless Steel Model Length Style Dimensions Pinout MQDEC-WDSS-401SS 0.3 m (1 ft) Male Straight/Female Straight 40 Typ. 43.5 Typ. 13.9 13.9 M12 x 1 Female Male 1 = Brown 2 = White 3 = Blue 4 = Black MQDEC-WDSS-403SS 0.91 m (3 ft) MQDEC-WDSS-406SS 1.83 m (6 ft) MQDEC-WDSS-412SS 3.66 m (12 ft) Brackets SMB30A

  • Right-angle bracket with curved slot for versatile orientation Clearance for M6 (¼ in) hardware
  • Mounting hole for 30 mm sensor
  • 12-ga. stainless steel A B C Hole center spacing: A to B=40 Hole size: A=ø 6.3, B= 27.1 x 6.3, C=ø 30.5 SMB30FA
  • Swivel bracket with tilt and pan movement for precise adjustment Mounting hole for 30 mm sensor
  • 12-ga. 304 stainless steel
  • Easy sensor mounting to extrude rail T-slot
  • Metric and inch size bolt available A B 68.936.3 83.2 Bolt thread: SMB30FA, A= 3/8 - 16 x 2 in; SMB30FAM10, A= M10 - 1.5 x 50 Hole size: B= ø 30.1 SMB30FVK
  • V-clamp, flat bracket and fasteners for mounting to pipe or extensions
  • Clamp accommodates 28 mm dia. tubing or 1 in. square extrusions
  • 30 mm hole for mounting sensors 118 A Hole size: A= ø 31 SMB30MM
  • 12-ga. stainless steel bracket with curved mounting slots for versatile orientation Clearance for M6 (¼ in) hardware
  • Mounting hole for 30 mm sensor A B C Hole center spacing: A = 51, A to B = 25.4 Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1 SMB30RAVK
  • V-clamp, right-angle bracket and fasteners for mounting sensors to pipe or extrusion Clamp accommodates 28 mm dia. tubing or 1 in. square extrusions
  • 30 mm hole for mounting sensors A Hole size: A = ø 30.5 SMB30SC
  • Swivel bracket with 30 mm mounting hole for sensor Black reinforced thermoplastic polyester
  • Stainless steel mounting and swivel locking hardware included B A Hole center spacing: A=ø 50.8 Hole size: A=ø 7.0, B=ø 30.0 K50 Pro Devices with IO-Link 6 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 208737 Rev. E
  • Flat SMBAMS series bracket 30 mm hole for mounting sensors
  • Articulation slots for 90°+ rotation
  • 12-ga. 300 series stainless steel 93 A C B Hole center spacing: A=26.0, A to B=13.0 Hole size: A=26.8 x 7.0, B=ø 6.5, C=ø 31.0 SMBAMS30RA
  • Right-angle SMBAMS series bracket 30 mm hole for mounting sensors
  • Articulation slots for 90°+ rotation
  • 12-ga. (2.6 mm) cold-rolled steel 53 A C B Hole center spacing: A=26.0, A to B=13.0 Hole size: A=26.8 x 7.0, B=ø 6.5, C=ø 31.0 TC-K50-CL
  • Touch cover Ø A B Diameter: A = 67 mm Height: B = 42.5 mm LMB30LP
  • Low profile 30 mm mounting hole
  • 300 series stainless steel 2 X Ø5.5 Ø30.5 LMB30LPC
  • For 28 mm tubular racking LMB30LP attached to clamp bracket
  • Toolless mount to racking
  • 30 mm mounting hole 2 X M5 x 0.8 Hex Nut Ø30.5 Ø28 Standard Laser Marking Options Circle Icon (add -CRCLI to model number) Power/Start Icon (add -STRTI to model number) Stop Icon (add -STOPI to model number) Reset Icon (add -RSETI to model number) Example: K50PTKQ-RSETI Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. K50 Pro Devices with IO-Link P/N 208737 Rev. E www.bannerengineering.com - Tel: + 1 888 373 6767 7

FCC Part 15 and CAN ICES-3 (B)/NMB-3(B) This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the manufacturer. K50 Pro Devices with IO-Link © Banner Engineering Corp. All rights reserved