K30_V08 BANNER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Compact, single-point devices for error-proofing of bin-picking operations
- FDA-grade materials; rated to IEC IP67, IP68, and IP69K
- Laser marked information withstands aggressive cleaning procedures
- Excellent immunity to false triggering by water spray, detergents, oils, and other foreign materials
- Rugged, cost-effective and easy-to-install solutions for error-proofing and parts- verification applications
- Compact devices are completely self contained—No controller needed
- Illuminated dome provides an easy-to-see green job light: some models also light red for alternate operation
- Easy actuation—no force required
- 12 to 30 V dc operation
- Can be actuated with bare hands or in gloves Models Model1 Function Output Connection Job Light K30APT2FGXDQP
- Job light is ON at all times while job input is active
- Touch activates output PNP, NO 150 mm (6 in) pigtail PVC cable with a 4- pin M12/Euro-style male, stainless steel, quick disconnect (QD) Green K30RPT2FGXDQP PNP, NC K30ANT2FGXDQP NPN, NO K30RNT2FGXDQP NPN, NC K30APT2FGRCQP
- Job light is Green while job input is active
- Touch activates output and overrides job light (turns Red) for visual verification that action was sensed PNP, NO Green (Red) K30RPT2FGRCQP PNP, NC K30ANT2FGRCQP NPN, NO K30RNT2FGRCQP NPN, NC K30APT2FGREQP • Job light is Green at all times while job input is active
- Touch activates output
- A touch while job input is inactive causes unit to light Red, providing visual verification that sensor is functioning properly PNP, NO Green (Red) K30RPT2FGREQP PNP, NC K30ANT2FGREQP NPN, NO K30RNT2FGREQP NPN, NC Specifications Supply Voltage 12 to 30 V dc Supply Current 55 mA max current (exclusive of load) Supply Protection Circuitry Protected against reverse polarity and transient voltages Output Rating Maximum Load: 150 mA ON-state saturation voltage: < 2 V at 10 mA dc; < 2.5 V at 150 mA dc OFF-state leakage current: <10 µA at 30 V dc Output Response Time: 150 milliseconds On and Off Power-Up Delay 300 milliseconds Construction Base, dome, and nut: FDA-grade polycarbonate Indicators Job ("Pick") Indicator: Green Pick Sensed Indicator: Red or Off, depending on model Mounting M22 × 1.5 Threaded base, max torque 2.25 N·m (20 in-lbf) Connections 150 mm (6 in) pigtail PVC cable with a 4-pin M12/Euro-style male, stainless steel, quick disconnect (QD) or 2 m (6.5 ft) unterminated PVC- jacketed cable, depending on model 1 To order the 2 m (6.5 ft) PVC cable models, omit suffix QP from model number (example, K30APT2FGXD). A model with a QD requires a mating cable (see Cordsets). EZ-LIGHT® Touch Gen 2 K30 FDA-Grade Pick-to-Light Original Document 189834 Rev. C
10 February 2016
Vibration and Mechanical Shock Vibration 10 Hz to 55 Hz 1.0 mm p-p amplitude per IEC 60068-2-6 Shock 30G 11 ms duration, half sine wave per IEC 60068-2-27 Environmental Rating IEC IP67, IP69K per DIN 40050-9. Storage Operating Conditions Temperature: –40 °C to +50 °C (–40 °F to +122 °F) Humidity: 90% at 50 °C maximum relative humidity (non- condensing) Certifications Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to http:// www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Dimensions M22 X 1.5 30.0 [1.18] 41.0 [1.62] 23.5 [.93] Wiring Diagrams NPN PNP Color Key 12-30V dc Job Light Enable < 1.0V dc
4 Load
Enable > 7V dc 1 = Brown 2 = White 3 = Blue 4 = Black Cabled wiring diagrams are shown. Quick disconnect (QD) wiring diagrams are functionally identical. EZ-LIGHT® Touch Gen 2 K30 FDA-Grade Pick-to-Light 2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 189834 Rev. C
4-Pin Threaded M12/Euro-Style Cordsets Model Length Style Dimensions Pinout (Female) MQDC-406 1.83 m (6 ft) Straight 44 Typ. ø 14.5 M12 x 1 1 = Brown 2 = White 3 = Blue 4 = Black MQDC-415 4.57 m (15 ft) MQDC-430 9.14 m (30 ft) MQDC-450 15.2 m (50 ft) MQDC-406RA 1.83 m (6 ft) Right-Angle 32 Typ.[1.26"] 30 Typ.[1.18"] ø 14.5 [0.57"] M12 x 1 MQDC-415RA 4.57 m (15 ft) MQDC-430RA 9.14 m (30 ft) MQDC-450RA 15.2 m (50 ft) 4-Pin Threaded M12/Euro-Style Cordsets—Washdown, Stainless Steel Model Length Style Dimensions Pinout (Female) MQDC-WDSS-0406 1.83 m (6 ft) Straight 43.5 mm Ø4.8 mm Ø15.5 mm 1 = Brown 2 = White 3 = Blue 4 = Black MQDC-WDSS-0415 4.57 m (15 ft) MQDC-WDSS-0430 9.14 m (30 ft) Brackets SMB22A
- Right-angle bracket with curved slot for versatile orientation
- 12-ga. stainless steel
- Mounting hole for 22 mm sensor 46 AB C Hole center spacing: A to B = 26.0 Hole size: A = ø 4.6, B = 4.6 x 16.9, C = 22.2 SMB22FVK
- V-clamp, flat bracket and fasteners for mounting to pipe or extensions
- Clamp accommodates 28 mm diameter tubing or 1 in. square extrusions
- 22 mm hole for mounting sensor 46 118 34Aø22.5 Hole size: A = ø 22.5 EZ-LIGHT® Touch Gen 2 K30 FDA-Grade Pick-to-Light P/N 189834 Rev. C www.bannerengineering.com - Tel: +1-763-544-3164 3
- V-clamp, right-angle bracket and fasteners for mounting to pipe or extensions
- Clamp accommodates 28 mm diameter tubing or 1 in. square extrusions
- 22 mm hole for mounting sensor A Hole size: A = ø 22.5 SMBAMS22P
- Flat SMBAMS series bracket with 22 mm hole for mounting sensors
- Articulation slots for 90+° rotation
- 12-ga. (2.6 mm) cold-rolled steel 93 A C B Hole center spacing: A = 26.0, A to B = 13.0 Hole size: A = 26.8 x 7.0, B = ø 6.5, C = ø 22.5 SMBAMS22RA
- Right-angle SMBAMS series bracket with 22 mm hole for mounting sensors
- Articulation slots for 90+° rotation
- 12-ga. (2.6 mm) cold-rolled steel A C B Hole center spacing: A = 26.0, A to B = 13.0 Hole size: A = 26.8 x 7.0, B = ø 6.5, C = ø 22.5 TC-K30-CL
- Touch cover Ø A B Diameter: A = 40.7 Height: B = 31 All measurements are listed in millimeters, unless noted otherwise. Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. EZ-LIGHT® Touch Gen 2 K30 FDA-Grade Pick-to-Light www.bannerengineering.com - Tel: +1-763-544-3164