K30_V07 BANNER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Compact, Single-Point Devices for Error Proofing of Bin-Picking Operations

  • Rugged, cost-effective and easy-to-install multicolor indicator light with pushbutton
  • Illuminated dome provides an easy-to-see green job light; some models also light red for alternate operation
  • Waterproof IP65 construction for washdown environments
  • Compact devices are self-contained — no controller needed
  • Immune to EMI and RFI interference
  • 12 V dc to 30 V dc operation
  • Cabled and quick disconnect models available WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Models Model Function Output Connection1 Job Light K30APPBGXDQ • Job light is ON at all times while job input is active.
  • Pressing push button activates output. PNP, NO Integral 4-pin M12/ Euro-style quick disconnect Green K30ANPBGXDQ NPN, NO K30APPBGRCQ • Job light is green while job input is active, until push button is pushed.
  • Pressing push button activates output and overrides job light (it turns Red) for visual verification that action was sensed. PNP, NO Green (Red) K30ANPBGRCQ NPN, NO K30APPBGREQ • Job light is ON at all times while job input is active.
  • Pressing push button activates output.
  • Pressing push button while job input is inactive causes unit to light Red, providing visual indication that sensor is functioning properly. PNP, NO Green (Red) K30ANPBGREQ NPN, NO Overview The solid-state output interfaces to a system controller, which is pre-programmed for a specific sequence of tasks. Mounted in or near each bin in an assembler’s work station, the sensor job light signals the assembler:
  • Which bins contain items to be picked in a given operation; and
  • In what order they should be picked. As the assembler takes a part in sequence and pushes the button, the sensor senses that the part was removed and sends an output signal to the controller. The controller verifies if the correct part was taken and may respond by turning that job light OFF, activating the job light of the next bin in the sequence. If multiple parts are to be removed from one bin, the job light may remain ON until the appropriate number of signals is returned to the controller. If an incorrect part is selected, the control system may be wired to signal an alarm for the assembler and/or a supervisor, or it may be programmed to interpret the action as a call for parts. 1 Integral quick disconnect models are listed.
  • To order the 2 m (6.5 ft) PVC cable model, omit the suffix "Q" in the model number. For example, K30APPBGXD.
  • Models with a quick disconnect require a mating cordset. EZ-LIGHT® K30 Series Pick-to-Light Sensors Original Document 155796 Rev. D

22 November 2016

Install the K30 sensor at such a height and in a location that will be easy for the user and/or supervisor to see the indicator and comfortable for the user to press the push-button. Wiring 12-30V dc Job Light Enable ≥ 8V dc Load 1 = brown 2 = white 3 = blue 4 = black Specifications Supply Voltage and Current 12 V dc to 30 V dc (10% max. ripple) at 50 mA maximum Supply/Output Protection Circuitry Protected against reverse polarity and transient voltages Output Rating Max. load: 150 mA ON-state saturation voltage: < 0.5 V at 10 mA dc; < 1.0 V at 150 mA dc OFF-state leakage current: < 10 μ A at 30 V dc Job Light Enable Input Impedance: 10 KOhms Input high > 8.0 V Environmental Rating IEC IP65 Enclosure Type 13 Construction Base: polycarbonate Translucent dome: polycarbonate Push button: thermoplastic Output Protection Protected against false pulse on power-up and continuous overload or short circuit of output. Output Response Time 1 millisecond On and Off Indicators Job ("Pick") Indicator: Green Pick Sensed Indicator: Red or OFF, depending on model Connections Integral 4-pin M12/Euro-style quick disconnect fitting, PVC-jacketed 2 m (6.5 ft) or 9 m (30 ft) cable, depending on model. Operating Conditions 90% at +50 °C maximum relative humidity (non-condensing) Storage Temperature Certifications Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 EZ-LIGHT® K30 Series Pick-to-Light Sensors 2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 155796 Rev. D

All measurements are listed in millimeters [inches], unless noted otherwise. Accessories Cordsets 4-Pin Threaded M12/Euro-Style Cordsets Model Length Style Dimensions Pinout (Female) MQDC-406 1.83 m (6 ft) Straight 44 Typ. ø 14.5 M12 x 1 1 = Brown 2 = White 3 = Blue 4 = Black MQDC-415 4.57 m (15 ft) MQDC-430 9.14 m (30 ft) MQDC-450 15.2 m (50 ft) MQDC-406RA 1.83 m (6 ft) Right-Angle 32 Typ.[1.26"] 30 Typ.[1.18"] ø 14.5 [0.57"] M12 x 1 MQDC-415RA 4.57 m (15 ft) MQDC-430RA 9.14 m (30 ft) MQDC-450RA 15.2 m (50 ft) Brackets SMB22A

  • Right-angle bracket with curved slot for versatile orientation
  • 12-ga. stainless steel
  • Mounting hole for 22 mm sensor

46 A B

C Hole center spacing: A to B = 26.0 Hole size: A = ø 4.6, B = 4.6 x 16.9, C = 22.2 EZ-LIGHT® K30 Series Pick-to-Light Sensors P/N 155796 Rev. D www.bannerengineering.com - Tel: +1-763-544-3164 3

Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. EZ-LIGHT® K30 Series Pick-to-Light Sensors © Banner Engineering Corp. All rights reserved