K246_EN Rev 2.0 1 K246 HIGH POWER LATCHING RELAY
- 2 00A Latching Relay
- Electrical endurance 6000 cycles
- 4kV dielectric strength between coil and contacts
- According to ANSI C12.1 (Carrying current: 12kA / 66.7ms; 7kA /100ms)
- Outline dimensions: (73.3 x 74.8 x 29.8)mm
- UL 508 Compliant *
- RoHS compliant materials and process Contact Data Characteristics Rated Load † 200A @ 240V Insulation resistance 1,000MΩ (at 500 Vdc) Contact form 2A or 2B Dielectric strength: Contact material AgSnO2 Coil to contact 4kVac for 1 min. Contact resistance ‡ 0.25mΩ (at 200A) 10kV 1.2µs/50µs Max. switching voltage 265 Vac Pole to Pole 8kV 1.2µs/50µs Max. carrying current 200 A Across open contacts 2k Vac for 1min. Max. switching current 200 A Dielectric creepage 9 .6 mm Rated switching power 48,000 VA Ambient temperature - 40°C to +85°C Set time ≤ 30 ms Ambient humidity 5% - 85% RH Reset time ≤ 30 ms Vibration 1.5 mm (DA) 10 Hz to 55 Hz Electrical endurance § 6 ,000 cycles Shock resistance: Mechanical endurance ** 100,000 cycles Functional †† 196 m/s2 Survival ‡‡ 980 m/s2 Coil termination PCB or Wire Unit weight 400g * Compliant to: UL 508; File Number: E178562 † Load at which the relay can pass ANSI C12.1 ‡ (Duration 11ms), 6 shocks (six ops in both directions of each of the three mutually perpendicular axes, totally 36 ops), No opening or closing of any closed or opened contact circuit respectively shall exceed 100 μs § Applies to both Form 2A and Form 2B products; Power Factor: 1.0; 240Vac / 200A @ 23°C; Duty Cycle: 1s ON/ 9s OFF ** Duty Cycle: 1s ON/ 1s OFF @ 23°C †† Unit may change state but is still functional ‡‡ Acceleration 980 m/s2 (Duration 6 ms)
K246_EN Rev 2.0 2 Coil Data Single Coil (Latching) Dual Coil (Latching) Coil Consumption 12W 24W Pulse Duration 50ms 50ms Coil Resistance (Ω±10%) at 23°C Nominal Coil Voltage Min Set/Reset Voltage Single Coil (Latching) Dual Coil (Latching) 6Vdc 4.8Vdc 3Ω 2 x 1.5Ω 9Vdc 7.2Vdc 6.75Ω 2 x 3.3Ω 12Vdc 9.6Vdc 12Ω 2 x 6Ω 24Vdc 19.2Vdc 48Ω 2 x 24Ω 48Vdc 38.4Vdc 192Ω 2 x 96Ω
Ordering Information
Terminal Type: A: See drawing X: Custom Design §§ Coil Type: S: Single Coil D: Dual Coil Coil Pin Position L: Coil pins on left of relay R: Coil pins on right of relay Coil Voltage *: 6 , 9, 12, 24, 48 Vdc Polarity: P: Positive N: Negative Contact Form: 2A: Form 2A – Normally Open (NO) 2B: Form 2B – Normally Closed (NC) Contact Material: T: AgSnO2 Manual Actuation: 1: No 2: Yes Auxiliary NIL: No auxiliary contact Switch Type: A: Switch state same as relay state (Pins exit from top) B: Switch state opposite to relay state (Pins exit from top) C: Switch state opposite to relay state (Pins exit from bottom) Custom Number: Cxxxx: Where xxxx represents a unique number for custom relay terminal designs §§ For custom designs, please contact KG Technologies. Integrated shunts, flex-wire, copper extension and brass terminals available * Coil voltage should be indicated in three-digit format (6Vdc = 006)
K246_EN Rev 2.0 3 Dimensional Drawings (Unit: mm) TYPE A CONTACT TERMINALS ; AUXILIARY CONTACT TYPE A (TOP VIEW) Dimensional Drawings (Unit: mm) TYPE A CONTACT TERMINALS ; AUXILIARY CONTACT TYPE B (TOP VIEW)
K246_EN Rev 2.0 4 Dimensional Drawings (Unit: mm) TYPE A CONTACT TERMINALS ; AUXILIARY CONTACT TYPE C (BOTTOM VIEW) Coil Wiring Diagrams ††† Single Coil Dual Coil Positive Polarity Negative Polarity Positive Polarity Negative Polarity ††† Manual switch is used to switch the load contacts Manual switch position to: A: Relay Contacts open; B: Relay Contacts closed Auxiliary contact state also changes with main contact state when manual switch is operated
K246_EN Rev 2.0 5 Auxiliary Contacts Wiring Diagrams Load Contact State Load Contact State Auxiliary Contact State Auxiliary Contact State Load Contact State Auxiliary Contact State ‡‡‡ For Part number: K246 ■-■ ■ ■ ■-■ T ■ A - Cxxx; Only auxiliary pins T8 and T10 are present on the product §§§ For Part number: K246 ■-■ ■ ■ ■-■ T ■ B - Cxxx; Only auxiliary pins T8 and T9 are present on the product **** For Part number: K246 ■-■ ■ ■ ■-■ T ■ C - Cxxx; Only auxiliary pins T11 and T12 are present on the product
K246_EN Rev 2.0 6 Application Notes 1. It is possible that during transit or final assembly the relay could change state. Therefore, it is recommended that all relays be set to the desired state via a power supply. 2. In order to maintain an “Open” or “Closed” state of the relay, the coil voltage should reach the rated vo ltage. The pulse width should be 50ms minimum to ensure a proper change of state. DO NOT energize both T1 and T3 at the same time on a Dual Coil or energize the coil for longer than 1 minute (damage to the coil could occur). 3. Applying excessive heat to the relay terminals (soldering or welding) can cause damage to the internal structure of the relay and should be avoided. 4. Moving or bending the terminals can cause damage to the internal structure of the relay and should be avoided. 5. For definitions of terms used in this data sheet, see glossary at www.kgtechnologies.net. Disclaimer: This datasheet is for reference only. All specifications are subject to change without prior notice. KG Technologies, Inc. cannot predict every possible application for our relays. While we do our best to make our relays as versatile as possible, we highly recommend contacting our engineering team if you have any questions. KG Technologies, Inc. is not responsible for malfunctioning relays when operated outside the specified parameters given in this datasheet.