K240_EN Rev 1.0 K240 200A POWER LATCHING RELAY

  • 200A switching capability
  • ANSI C12.1 compliant: Carrying: 12kA / 66.7ms; 7kA / 100ms
  • 4kV dielectric strength
  • Switching power up to 48.0kVA
  • Outline dimensions: (73.3 x 74.8 x 29.5)mm
  • RoHS compliant
  • Tin plating of terminals is available Contact Data Characteristics Contact form 2A, 2B Insulation resistance 1,000MΩ (at 500Vdc) Contact resistance * 0.25mΩ max (@ 200A) Dielectric strength: Contact material AgSnO2 Coil to contact 4kVac for 1 min. Contact rating † 200A @ 240Vac 10kV / 1.2 / 50µs Max. switching voltage 265Vac Across open contacts 2kVac for 1min. Max. switching current 200A Creepage distance 9.6 mm Max. switching power 48,00VA ‡ / 5,600W § Ambient temperature -40°C to +85°C Set time ≤ 20 ms Ambient humidity 5% - 85% RH Reset time ≤ 20 ms Vibration 1.5 mm (DA) 10 Hz to 55 Hz Electrical endurance 6,000 cycles ** Shock resistance: Mechanical endurance 100,000 cycles Functional †† 98 m/s2 Construction Dust protected Destructive 980 m/s2 Coil termination PCB Unit weight ±400g * Typical value for Initial Contact Resistance: Using a sample quantity of at least 20 units, take the average value from 5 continuous measurements from each sample † Load at which the relay can pass ANSI C12.1 (Applies to 240Vac rating only) ‡ AC Rating § DC Rating @ 28Vdc ** Electrical endurance at 240Vac / 200A; Power Factor: 1.0 †† Unit may change state but is still functional

K240_EN Rev 1.0 Coil Resistance (Ω±10%) at 23°C Nominal Coil Voltage Min Set/Reset Voltage Single Coil (Latching) Dual Coil (Latching) 6Vdc 4.8Vdc 3Ω 2 x 1.5Ω 9Vdc 7.2Vdc 6.75Ω 2 x 3.3Ω 12Vdc 9.6Vdc 12Ω 2 x 6Ω 24Vdc 19.2Vdc 48Ω 2 x 24Ω 48Vdc 38.4Vdc 190Ω 2 x 95Ω

Ordering Information

Terminal Type: A: See drawing B: See drawing X: Custom Design ‡‡ Coil Type: S: Single Coil D: Dual Coil Coil Pin Position: L: Coil pins on left of relay R: Coil pins on right of relay Coil Voltage §§: 6, 9, 12, 24, 48 Vdc Polarity: P: Positive N: Negative Contact Form: 2A: Form 2A – Normally open (NO) 2B: Form 2B – Normally closed (NC) Contact Material: T: AgSnO2 Custom Number: Cxxxx: Where xxxx represents a unique number for custom relay terminal designs ‡‡ For custom designs, please contact KG Technologies §§ Coil voltage should be indicated in three-digit format (6Vdc = 006) Coil Data Single Coil (Latching) Dual Coil (Latching) Coil Consumption 12W 24W Pulse Duration 50ms 50ms

K240_EN Rev 1.0 Dimensional Drawings (Unit: mm) K240A FORM 2A & 2B

K240_EN Rev 1.0 Dimensional Drawings (Unit: mm) K240B FORM 2A & 2B

K240_EN Rev 1.0 Wiring Diagrams Single Coil Dual Coil Positive Polarity Negative Polarity Disclaimer: This datasheet is for reference only. All specifications are subject to change without prior notice. KG Technologies, Inc. cannot predict every possible application for our relays. While we do our best to make our relays as versatile as possible, we highly recommend contacting our engineering team if you have any questions. KG Technologies, Inc. is not responsible for malfunctioning relays when operated outside the specified parameters given in this datasheet. Application Notes 1. It is possible that during transit or final assembly the relay could change state. Therefore, it is recommended that all relays be set to the desired state via a power supply. 2. In order to maintain an “Open” or “Closed” state of the relay, the coil voltage should reach the rated voltage. The pulse width should be 50ms minimum to ensure a proper change of state. DO NOT energize both T1 and T3 at the same time on a Dual Coil or energize the coil for longer than 1 minute (damage to the coil could occur). 3. Moving or bending the terminals can cause damage to the internal structure of the relay and should be avoided. 4. For definitions of terms used in this data sheet, see glossary at https://kgtechnologies.net/