K219_en Rev 3 1 R K219 HIGH POWER LATCHING RELAY  90A Latching Relay  UC2 capability as per IEC 62055-31: Rated Breaking Current (Ic) = 60A Reference Voltage (Un) = 240V Rated Breaking Voltage (Uc) = 276V  4kV dielectric strength between coil and contacts.  Outline dimensions: (54.9 x 35 x 19.5)mm.  Custom assemblies available with flex wire and/or copper extensions, and/or with integrated shunt.  RoHS compliant materials and process. Contact Data Characteristics Rated Load* 60A @ 276V Insulation resistance 1,000MΩ (at 500 Vdc) Contact form 2A or 2B Dielectric strength: Contact material AgSnO2 Coil to contact 4kVac for 1 min. Contact resistance† 0.7mΩ (at 80 A) 10kV 1.2us/50us Max. switching voltage‡ 276 Vac Pole to Pole 8kV 1.2us/50us Max. carrying current 90 A Across open contacts 2kVac for 1min. Max. switching current§ 60 A Dielectric creepage 8.9 mm Rated switching power 16,560 VA Ambient temperature -40°C to +85°C Set time ≤ 30 ms Ambient humidity 5% - 85% RH Reset time ≤ 30 ms Vibration 1.5 mm (DA) 10 Hz to 55 Hz Electrical endurance 10,000 cycles Shock resistance: Mechanical endurance 100,000 cycles Functional** 98 m/s2 Survival 980 m/s2 Coil termination PCB or Wire Unit weight 75g * Load at which the relay can pass UC2 as per IEC 62055-31 † Typical value for initial contact resistance per relay pole: Using a sample quantity of at least 20 units, take the average value from 5 continuous measurements from each sample. ‡ Voltage at which the relay can pass electrical endurance testing as per IEC 62055-31 § Current at which the relay can pass UC2 as per IEC 62055-31 ** Unit may change state but is still functional

K219_en Rev 3 2 Coil Data Single Coil (Latching) Dual Coil (Latching) Coil Consumption 3W 6W Pulse Duration 50ms 50ms Coil Resistance (Ω±10%) at 23°C Nominal Coil Voltage Min Set/Reset Voltage Single Coil (Latching) Dual Coil (Latching) 6Vdc 4.8Vdc 12Ω 2 x 6Ω 9Vdc 7.2Vdc 27Ω 2 x 13.5Ω 12Vdc 9.6Vdc 48Ω 2 x 24Ω 24Vdc 19.2Vdc 192Ω 2 x 96Ω 48Vdc 38.4Vdc 768Ω 2 x 384Ω

Ordering Information

K219 ☐ -☐ ☐ ☐ -☐ T -Cxxxx Relay Series Terminal Type: A: See drawing X: Custom Design†† Coil Type: S: Single Coil D: Dual Coil Coil Voltage‡‡: 6,9,12,24,48 Vdc Polarity: P: Positive N: Negative Contact Form: 2A: Form 2A – Normally open (NO) 2B: Form 2B – Normally closed (NC) Contact Material: T: AgSnO2 Custom Number: Cxxxx: Where xxxx represents a unique number for custom relay terminal designs. †† For custom designs, please contact KG Technologies. Integrated shunts, flex-wire, copper extension and brass terminals available. ‡‡ Coil voltage should be indicated in three-digit format (6Vdc = 006)

K219_en Rev 3 3 Dimensional Drawings (Unit: mm) Type A Contact Terminals Terminal Layout

K219_en Rev 3 4 Wiring Diagrams Single Coil Dual Coil Positive Polarity Negative Polarity Positive Polarity Negative Polarity Application Notes 1. It is possible that during transit or final assembly the relay could change state. Therefore, it is recommended that all relays be set to the desired state via a power supply. 2. In order to maintain an “Open” or “Closed” state of the relay, the coil voltage should reach the rated voltage. The pulse width should be 50ms minimum to ensure a proper change of state. DO NOT energi ze both T1 and T3 at the same time on a Dual Coil or energize the coil for longer than 1 minute (damage to the coil could occur). 3. Applying excessive heat to the relay terminals (soldering or welding) can cause damage to the internal structure of the relay and should be avoided. 4. Moving or bending the terminals can cause damage to the internal structure of the relay and should be avoided. 5. For definitions of terms used in this data sheet, see glossary at www.kgtechnologies.net. Disclaimer: This datasheet is for reference only. All specifications are subject to change without prior notice. KG Technologies, Inc. cannot predict every possible application for our relays. While we do our best to make our relays as versatile as possible, we highly recommend contacting our engineering team if you have any questions. KG Technologies, Inc. is not responsible for malfunctioning relays when operated outside the specified parameters given in this datasheet.