K17M0142F2 ASHCROFT | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 4
Technical content
All specifications are subject to change without notice. All sales subject to standard terms and conditions. ©2020 Ashcroft Inc. K1_transducer_ds_RevB_09-03-20 ashcroft.com info@ashcroft.com 1.800.328.8258 K1 Pressure Transmitter Data Sheet
FEATURES
Pressure ranges from vacuum through 20,000 psi Choice of ±0.5% or ±1.0% accuracy All SS wetted parts FM approved (optional) NEMA 4X enclosure Wide range of electrical connections available Optional panel meter digital display – see Ashcroft model DM61 TYPICAL USES Hydraulic Refrigeration Machine tool Test/measurement Pump control HVAC Medical Construction equipment All general purpose industrial process applications KEY BENEFITS
- Proven sensor technology and performance
- Long time choice for many industrial
applications
- Superior long-term stability and repeatability PERFORMANCE SPECIFICATIONS Reference Temperature: 68°F (20°C) Accuracy Class (% Span): ±0.5%, ±1.00% of span Includes non-linearity, hysteresis, non- repeatability, zero offset and span setting errors Best Fit Straight Line (BFSL): Add ± 0.05% for ranges above 5000 psi Durability: > 10 million cycles Stability: ±0.5% Span/year at reference conditions ENVIRONMENTAL SPECIFICATIONS Temperature Limits: Storage: Operating: Compensated: –65°F to 250°F (–54°C to 121°C) –20°F to 180°F (–28°C to 82°C) –20°F to 160°F (–28°C to 71°C) Thermal Coefficients: (ref. 68°F (20°C)) Accuracy: 0.5% 1% Humidity Effects: No performance effect at 95% relative humidity-noncondensing Thermal Zero Coefficients: 1.5 on 0/30 psi, vac/15 range and by 3 on 0/15 and vac/0 ranges FUNCTIONAL SPECIFICATIONS Response Time: <5ms Pressure Ranges: 15 to 20,000 psig, compound to 60 psig Shock Effect: Less than ±0.05% F.S. effect for 100 g’s, 20ms shock in any axis Vibration Effect: Less than ±0.1% F.S. effect for 0-2,000 Hz at 20 g’s in any axis Position Effect: Less than ±0.01% F.S. Standard Ranges (psi, gauge, compund): 0/15* 0/30* 0/60* 0/7500* 0/10,000* 0/15,000* 0/20,000* vac./60* vac./45* vac./30* vac./15* vac./0* * 1% accuracy ranges only Overpressure: ≤2,000 psi ≥3,000 to ≤5,000 psi ≥7,500 to ≤20,000 psi Proof:
2 X Range
1.5 X Range
1.2 X Range
Burst:
8 X Range
3 X Range
All specifications are subject to change without notice. All sales subject to standard terms and conditions. ©2020 Ashcroft Inc. K1_transducer_ds_RevB_09-03-20 ashcroft.com info@ashcroft.com 1.800.328.8258 K1 Pressure Transmitter Data Sheet ELECTRICAL SPECIFICATIONS Output Signal: 4-20mA (2 wire) 1-5 Vdc (3 wire) 1-6 Vdc (3 wire) 1-11 Vdc (3 wire) (Min. excitation 15 Vdc) Power Requirements Unregulated: 10-36 Vdc Voltage Output: <3mA Circuit Protection: Reverse polarity and miss-wire protected Insulation Resistance (Circuit Case):
100 MΩ @ 100 Vdc
Rating: NEMA 4X (NEMA 1 only if <500 psig if electrical ter- mination is Bendix® or K1 part codes B4 & B6) Weight: 2 oz. (approx. w/o cable) Cable: No. 24 AWG, 36” PVC, shielded and vented Process Connection Sizes: 1/8 NPT Male or Female ¼ NPT Male or Female ¼ SAE-J-514 Male 9/16-18 UNF 2B AMINCO Female (over 10,000 psi) HAZARDOUS SPECIFICATIONS (K1 with XFM option) Intrinsically Safe – FM/CSA Intrinsic Safety: Class I, II and III Div. 1 Groups A, B, C, D, F and G when used with safety barriers in accordance with Ashcroft drawing 71B212 Sht (1-3) Non-incendive: Class I, II and III Div. 2, Groups A, B, C, D, F and G, no barriers needed WETTED MATERIAL Diaphragm Process Connection 17-4PH SS 304 SS NON-WETTED Housing 304 SS OPTIONAL FEATURES Calibration: Non-standard Approval: FM (with 4-20mA output and XFM option code) Thermal Coefficients: (ref. 68°F (20°C)) (0.5% Accuracy): ZERO ±0.014% SPAN ±0.014% Consult factory for: Nonstandard ranges, more Process Connection sizes and Output Signal non-standard options 1000 750 500 250 03 62010 1182 (R LOOP) 636 LOAD LIMITATIONS 4-20mA OUTPUT ONLY Loop Supply Voltage (VDC) V min = 10V+ (.022A x R L R L = R S + R W R L = Loop Resistance (ohms) R S = Sense Resistance (ohms) R W = Wire Resistance (ohms)
All specifications are subject to change without notice. All sales subject to standard terms and conditions. ©2020 Ashcroft Inc. K1_transducer_ds_RevB_09-03-20 ashcroft.com info@ashcroft.com 1.800.328.8258 K1 Pressure Transmitter Data Sheet ORDERING CODE Example: K1 7 M01 42 F2 100# XCL Model K1 - Pressure Transmitter K1 Accuracy/Tem. Effects Pressure Connection Size M01 - 1/8 NPT Male M01 M02 - ¼ NPT Male F02 - ¼ NPT Female MEK - 7/16-20 SAE Male F09 - 9/16-18 (¼) Female Aminco ® M04 - ½ NPT Male Output Signal 42 - 4-20 mA 42 15 - 1-5 Vdc 16 - 1-6 Vdc 11 - 1-11 Vdc 12 - 0.1-10 Vdc Electrical Termination F2 - 3´ shielded cable Integral Cable (Pigtail) F2 HM - W/o mating connection Hirschmann ® G series connector (minature type) B4 - W/o mating connection 4-Pin Bendix ® style B6 - W/o mating connection 6-Pin Bendix ® style B8 - W/o mating connection environmentall sealed/moisture proof 4-Pin Bendix ® style B9 - W/o mating connection environmentall sealed/moisture proof 6-Pin Bendix ® style C1 - 3´ shielded cable ½ NPT Male conduit shielded cable Standard Pressure Ranges 15# - 15 psi 30# - 30 psi 60# - 60 psi 100# - 100 psi 100# 150# - 150 psi 200# - 200 psi 300# - 300 psi 500# - 500 psi 750# - 750 psi 1000# - 1,000 psi 2000# - 2,000 psi 3000# - 3,000 psi 5000# - 5,000 psi 7500# - 7,500 psi 10000# - 10,000 psi 15000# - 15,000 psi (K1) with F09 code process conn. 20000# - 20,000 psi (K1) with F09 code process conn. 0# & vac - 0/vac 15# & vac - vac/15 psi 30# & vac - vac/30 psi 45# & vac - vac/45 psi 60# & vac - vac/60 psi 100# & vac - vac/100 psi Option (if including an option(s) must include an “X’’) X__ CL - Non-standard calibration CL FM - FM Approval option (K1 only with 4-20 mA)
All specifications are subject to change without notice. All sales subject to standard terms and conditions. ©2020 Ashcroft Inc. K1_transducer_ds_RevB_09-03-20 ashcroft.com info@ashcroft.com 1.800.328.8258 K1 Pressure Transmitter Data Sheet 3.0 HEX 6-PIN BENDIX 0.9 SQ. 4-PIN BENDIX 0.8 SQ. 3.0 DIMENSIONS in [ ] are millimeters For reference only, consult Ashcroft for specific dimensional drawings