K137_en Rev 1 1 R K137 HIGH POWER LATCHING RELAY 100A Latching Relay 4kV dielectric strength between coil and contacts. Outline dimensions: (43.2 x 37.2 x 22.0)mm. Custom assemblies available with flex wire and/or copper extensions, and/or with integrated shunt. RoHS compliant materials and process. Contact Data Characteristics Rated Load 100A @ 240V Insulation resistance 1,000MΩ (at 500 Vdc) Contact form 1A or 1B Dielectric strength: Contact material AgSnO2 Coil to contact 4kVac for 1 min. Contact resistance* 0.35mΩ (at 100 A) 12kV 1.2us/50us Max. switching voltage 440 Vac Across open contacts 2kVac for 1min. Max. carrying current 100 A Dielectric creepage 8 mm Max. switching current 100 A Ambient temperature -40°C to +85°C Rated switching power 24,400 VA Ambient humidity 5% - 85% RH Set time ≤ 20 ms Vibration 1.5 mm (DA) 10 Hz to 55 Hz Reset time ≤ 20 ms Shock resistance: Electrical endurance 10,000 cycles Functional† 98 m/s2 Mechanical endurance 100,000 cycles Survival 980 m/s2 Coil termination PCB or Wire Unit weight 75g * Typical value for Initial Contact Resistance: Using a sample quantity of at least 20 units, take the average value from 5 continuous measurements from each sample. † Unit may change state but is still functional
K137_en Rev 1 2 Coil Data Single Coil (Latching) Dual Coil (Latching) Coil Consumption 3W 6W Pulse Duration 50ms 50ms Coil Resistance (Ω±10%) at 23°C Nominal Coil Voltage Min Set/Reset Voltage Single Coil (Latching) Dual Coil (Latching) 6Vdc 4.8Vdc 12Ω 2 x 6Ω 9Vdc 7.2Vdc 27Ω 2 x 13.5Ω 12Vdc 9.6Vdc 48Ω 2 x 24Ω 24Vdc 19.2Vdc 192Ω 2 x 96Ω 48Vdc 38.4Vdc 768Ω 2 x 384Ω
Ordering Information
K137 ☐ -☐ ☐ ☐ -☐ T 2 -Cxxxx Relay Series Terminal Type: A: See Drawing X: Custom Design‡ Coil Type: S: Single Coil D: Dual Coil Coil Voltage§: 6,9,12,24,48 Vdc Polarity: P: Positive N: Negative Contact Form: 1A: Form 1A – Normally open (NO) 1B: Form 1B – Normally closed (NC) Contact Material: T: AgSnO2 Contact Type: 2: Dual contact Custom Number: Cxxxx: Where xxxx represents a unique number for custom relay terminal designs. ‡ For custom designs, please contact KG Technologies. Integrated shunts, flex-wire, copper extension and brass terminals available. § Coil voltage should be indicated in three-digit format (6Vdc = 006)
K137_en Rev 1 3 Dimensional Drawings (Unit: mm) Type A Contact Terminals
K137_en Rev 1 4 Wiring Diagrams (Unit: mm) Dual Coil Positive Polarity Negative Polarity Application Notes 1. It is possible that during transit or final assembly the relay could change state. Therefore, it is recommended that all relays be set to the desired state via a power supply. 2. In order to maintain an “Open” or “Closed” state of the relay, the coil voltage should reach the rated voltage. The pulse width should be 50ms minimum to ensure a proper change of state. DO NOT energize both T1 and T3 at the same time on a Dual Coil or energize the coil for longer than 1 minute (damage to the coil could occur). 3. Applying excessive heat to the relay terminals (soldering or welding) can cause damage to the internal structure of the relay and should be avoided. 4. Moving or bending the terminals can cause damage to the internal structure of the relay and should be avoided. 5. For definitions of terms used in this data sheet, see glossary at www.kgtechnologies.net. Disclaimer: This datasheet is for reference only. All spec ifications are subject to change without prior notice. KG Technologies, Inc. cannot predict every possible application for our relays. While we do our best to make our relays as versatile as possible, we highly recommend contacting our engineering team if you have any questions. KG Technologies, Inc. is not responsible for malfunctioning relays when operated outside the specified parameters given in this datasheet.