Features
High Daylight Visibility, Multicolor Indicator with Optional Audible Alarm for Indoor or Outdoor Use Highly visible indicator provides bright, even light in direct sunlight Ex/HazLoc approvals for potentially explosive environment applications Three colors in one device 36 mm threaded polycarbonate base Rugged IP69K per DIN 40050-9, UL Type 4X housing Variety of connector options Rugged UV-stabilized polycarbonate base and window
100 V AC to 240 V AC operating voltage
IK10 impact rating for maximum protection Models Standard models shown. Contact factory for other options. Family K100 Blank = 2 m integral ITC-ER PVC cable Q = 5-pin 1/2 in. 20 UNF male quick disconnect * Q Connector P Style Color 1 * G G = Green Color 2 Y R = Red Color 3 R Audible A Blank = None Models with a quick disconnect require a mating cordset * Must be enclosed with a protected conduit or a suitable enclosure* Optional color: Blue Z Classification N Installation Instructions Ex/HazLoc Applications WARNING: Explosive Atmospheres/Hazardous Locations It is the user's responsibility to ensure that all local, state, and national laws, rules, codes, or regulations relat- ing to the installation and use of this device in any particular application are satisfied. This device must be in- stalled by a Qualified Person(1), in accordance with this document and applicable regulations. WARNING: Explosion Hazard Do not disconnect equipment unless the power has been switched off or the area is known to be non-haz- ardous. CAUTION: Electrostatic Discharge (ESD) Special Conditions for Safe Use Parts of the enclosure are non-conducting and can generate an ignition-capable level of ESD. Clean the equipment with only a damp cloth. General Notes and Conditions for Use See Specifications and Wiring Diagrams for important information concerning entity parameters, permissible locations, electrical connections and certifications. In addition to the warning above concerning user responsibility, the installation must comply with the following: All installations must comply with all manufacturer's instructions. © Banner Engineering Corp.
June 09, 2023page 2 (1) Aggressive substances—for example, acidic liquids or gases that may attack metals, or solvents that may affect polymeric materials. (2) Suitable precaution—for example, regular checks as part of routine inspections or establishing from the materials data sheet that is resistant to specific chemi- cals. K100 Pro Hazardous Daylight Visible Beacon - AC Datasheet All applicable wiring methods in accordance with the relevant local regulations and the authority having jurisdiction. U.S. Installations: The relevant requirements of the National Electric Code® (ANSI/NFPA-70 NEC®). Canadian Installations: The relevant requirements of the Canadian Electrical Code (CSA C22.1). Do not attempt any repairs to this device; it contains no field-replaceable parts or components. Tampering and/or replacement with non-factory components may adversely affect the safe use of the system. The nonconducting materials of this device may be susceptible to ignition-capable level of electrostatic charging and precautions must be taken to avoid this. The user/installer shall ensure that the equipment is not installed in a location where it may be subjected to external conditions (such as high-pressure steam) which are conducive to creating a build-up of electrostatic charges. Clean with a damp cloth only. If the equipment is likely to come into contact with aggressive substances(1), then it is the responsibility of the user to take suitable precautions(2) that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised. The ingress protection (IP rating) of enclosures/panels may be invalidated by the installation of the beacon. The installation of the beacon in a particular enclosure/panel is subject to the evaluation/acceptance of the authority having jurisdiction. Models with integral quick-disconnect (QD) connectors: Use recommended Banner cordsets (see "Cordsets" on page 5), or suitable quick-disconnect cordsets with threaded retain- ing nut (see "Specifications" on page 3). The cordset must be securely fastened using the quick-disconnect retaining nut to prevent disconnection. Maximum connector torque: 6 ft-lbs. Must be installed such that the connector is protected from impact and unauthorized disconnection. The method of protec- tion can include conduit (e.g. pole, pendent), enclosed raceway, a listed enclosure suitable for the intended use, and/or by inaccessible location that excludes possible impact damage. Wiring Diagram Key A Neutral Hot 1 = Brown 2 = Blue 3 = White 4 = Black 5 = Gray An "X" denotes an active input. For example: When Input 1 and Input 3 are both active, the indicator will be Color 1 Flashing at 1 Hz. Default Configuration Wiring Operating Mode/Function Brown (Input Blue (Input 2) Black (Input Gray (Input 4) Non-Audible Audible X Color 1 Steady Color 1 Steady X Color 2 Steady Color 2 Steady X Color 3 Steady Color 3 Steady X X Color 1 Flashing at 1 Hz Color 1 Flashing at 1 Hz X X Color 2 Flashing at 1 Hz Color 2 Flashing at 1 Hz X X Color 3 Flashing at 1 Hz Color 3 Flashing at 1 Hz X X X Color 3, 3-pulse Strobe Color 3, 3-pulse Strobe X Off Audible Steady, Frequency 2.5 KHz, Volume High X X Color 1 Steady Color 1 Steady, Audible Steady, Frequency 2.5 KHz, Volume High X X Color 2 Steady Color 2 Steady, Audible Steady, Frequency 2.5 KHz, Volume High X X Color 3 Steady Color 3 Steady, Audible Steady, Frequency 2.5 KHz, Volume High X X X Color 1 Flashing at 1 Hz Color 1 Flashing at 1 Hz, Audible Steady, Frequency 2.5 KHz, Volume High X X X Color 2 Flashing at 1 Hz Color 2 Flashing at 1 Hz, Audible Steady, Frequency 2.5 KHz, Volume High X X X Color 3 Flashing at 1 Hz Color 3 Flashing at 1 Hz, Audible Steady, Frequency 2.5 KHz, Volume High X X X X Color 3, 3-pulse Strobe Color 3, 3-pulse Strobe, Audible Steady, Frequency 2.5 KHz, Volume High © Banner Engineering Corp.
K100 Pro Hazardous Daylight Visible Beacon - AC Datasheet June 09, 2023 page 3 Specifications Supply Protection Circuitry Protected against reverse polarity and transient voltages Leakage Current Immunity 400 µA The use of relay output PLC is recommended since there is no leakage current. Solid state output PLCs often have leak- age current above 1 mA and, therefore, turn the light on in the off state. To counteract the leakage current, a shunt resistor must be used. A resistor must be applied from the neutral wire of the device to the hot wire of each channel of the device. Indicator Response Time On Response: 350 ms (maximum) Off Response: 20 ms (maximum) Audible Characteristics Sound Intensity at 2.5 KHz, at 1 m (typical): Low volume setting: 93 dB Medium volume setting: 96 dB High volume setting: 101 dB Construction Base, Dome, and Nut: Polycarbonate Operating Conditions 90% at +50 °C maximum relative humidity (non-condensing) Storage Temperature: –40 °C to +70 °C (–40 °F to +158 °F) Connections Integral 5-pin 1/2 in. 20UNF male quick-disconnect connec- tor or 2 m (6.5 ft) integral ITC-ER PVC-jacketed cable, de- pending on model Models with a quick disconnect require a mating cordset Connecting 5-pin M12 quick-disconnect cordsets (see "Cord- sets" on page 5): Female single-ended Multiconductor cable (at minimum): UL Style 2517, 24 AWG wire, rated ≥ 80 °C; M12 quick-disconnect connector: per IEC 61076-2-101, must have threaded M12 x 1 retaining nut Mounting M36 by 2.0 threaded base, maximum torque 5.0 N·m (44 inch-lbf) Interior 3/4-14 NPT Thread Mounting nut included Adjacent Unit Mounting Separation Distance Minimum: 0 in (mounted with unit flanges touching) Approvals NEC and CEC (cULus) Gas and Vapors: Class I Div 2 Groups ABCD T4 Dust and Fibers/flyings: Class II Div 2 Groups FG T6; Class III Div 1 and Div 2 T6 Maximum Input Power Light Only: 12.1 W Light and Audible: 13.7 W Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 30G 11 ms dura- tion, half sine wave) Impact: IK10 (60068-2-75) Environmental Rating IP66, IP69K per DIN 40050-9, UL Type 4X LED Lifetime Lumen maintenance L70 When operating within specifications, output decreases less than 30% after 42,000 hours Certifications E530817 Supply Voltage and Current
100 V AC to 240 V AC, 50 Hz to 60 Hz
Maximum Current (mA AC at 60 Hz) Steady On, Flash, or Strobe Function(1) Rotate Function Light Only Light & Audible Light Only Light & Audi- ble 100 140 154 96 100 230 78 85 62 68 Default Indicator Characteristics Color Dominant Wavelength (nm) or Color Tempera- ture (CCT) Color Coordi- nates(2) Lumen Output (Typical at 25 °C) x y Green 528 nm 0.1603 0.6973 360 Yellow 589 nm 0.5557 0.4276 525 Red 625 nm 0.6999 0.2982 155 Blue 475 nm 0.1167 0.1121 165 Internal temperature compensation circuitry: Reduces the Lu- men Output to decrease the unit internal operating tempera- ture. The amount of reduction is dependent on the ambient operating temperature, supply voltage, color, and/or audible functions being utilized. (1) Flash or Strobe Mode: Peak current, operating at 50% duty cycle or less. (2) Refer to CIE 1931 chromaticity diagram or color chart, to show equivalent color with indicated color coordinates. © Banner Engineering Corp.
June 09, 2023page 4 (1) Red shown. See Base Candela table. K100 Pro Hazardous Daylight Visible Beacon - AC Datasheet Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in ac- cordance with local and national electri- cal codes and regulations. Overcurrent protection is required to be provided by end prod- uct application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (A) Supply Wiring (AWG) Required Overcurrent Protection (A) 20 5.0 26 1.0 22 3.0 28 0.8 24 1.0 30 0.5 Photometric Data Multiply the values shown in the chart by the maximum candela values in the Max. Candela table: 180°1.2 0.8 0.6 0.4 0.2 0.2 0.4 0.6 0.8 1.2 170°160°150° 140° 130° 120° 100° 90° 80° 70° 60° 50° 40° 30° 20°10°0° Polar Candela Distribution 90° Horizontal Base Candela Green 46 Yellow 67 Red 20 Blue 21 Candela Viewing Angle Example – Red Angle Factor Base(1) Candela 120 (top view) 0.7 20 14 90 (side view) 1 20 20 60 (bottom view) 0.7 20 14 Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. © Banner Engineering Corp.
K100 Pro Hazardous Daylight Visible Beacon - AC Datasheet June 09, 2023 page 5 Standard Models Audible Models 80.9 [3.18] Ø 92.8 [3.65] Ø 118.5 [4.67] 134.7 [5.3] 25.5 [1.01] 13.0 [0.51] M36 x 2.0 Interior T 1/2 - 20 81.0 [3.19] Ø 92.8 [3.65] [4.67] 134.8 [5.31] 25.5 [1.01] 13.0 [0.51] M36 x 2.0 Interior 1/2 - 20 Accessories Cordsets All measurements are listed in millimeters, unless noted otherwise. 5-Pin 1/2-in Dual Key Cordsets—Single Ended Model Length Style Dimensions Pinout MQAC2-506 2 m (6.56 ft) Straight ø 14.5 1/2-20 UNF-2B 1 = Brown 2 = Blue 3 = White 4 = Black 5 = Gray MQAC2-515 5 m (16.4 ft) MQAC2-530 9.14 m (30 ft) Brackets LMB36RA Indicator light right-angle mounting 36 mm mounting hole Stainless steel 50.8 25.44 X Ø6.5 62.5 Ø36.5 © Banner Engineering Corp.
June 09, 2023page 6 K100 Pro Hazardous Daylight Visible Beacon - AC Datasheet Elevated Mount System Model Features Components Black Anodized Alu- minum ¾ in. NPT Black Anodized Aluminum ½ in. NPT Clear Anodized Alu- minum ½ in. NPT SOP-E34-150A 150 mm (6 in) long SOP-E12-150A 150 mm (6 in) long SOP-E12-150AC 150 mm (6 in) long Elevated-use stand-off pipe Black anodized aluminum or clear an- odized aluminum surface Threaded at both ends Compatible with most industrial environ- ments SOP-E34-300A 300 mm (12 in) long SOP-E12-300A 300 mm (12 in) long SOP-E12-300AC 300 mm (12 in) long SOP-E34-600A 600 mm (24 in) long SOP-E12-600A 600 mm (24 in) long — SOP-E34-900A 900 mm (36 in) long SOP-E12-900A 900 mm (36 in) long SOP-E12-900AC 900 mm (36 in) long SA-M36E12 Adapter from M36 thread to 12-14 NPSM thread Streamlined black plastic mounting base adapter/cover Drilled hole SA-M36SOP M36 thread adapter with clearance for ¾ pipe mount Streamlined black plastic mounting base adapter/cover Drilled hole Pipe Mounting Flange Model Features Construction SA-F12 Elevated-use stand-off pipes (½ in, NPSM/ DN15) M5 mounting hardware and nitrile gasket included Die-cast zinc base with black paint ø28 ø70 4x ø5.5 Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of ship- ment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUD- ING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BAN- NER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or lia- bilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installa- tion of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the prod- uct warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other lan- guage. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. © Banner Engineering Corp.