Contact Data Click here for glossary of terms Rated Load 100A 277V ac Contact form 1A or 1B C ontact material A gSnO2 Max. switching voltage 440V ac Max. switching current 100A M ax. switching power: 27,700V A (AC switching) 2,800W (DC swit ching) Electrical endurance 10,000 c ycles Mechanical endurance 100,000 c ycles Characteristics Click here for glossary of terms Insulation resistance 1,000 MΩ (a t 500VDC) Dielectric strength: C oil to contact 4,000 Vac for 1 min. A cross open contacts 2,000 Vac for 1 min. Dielectric creepage ≥8mm Oper ating temperature -40 t o +85°C Ambient humidity 98% RH, +40°C V ibration 1.5mm (D A), 10 to 55 Hz Shock resistance: Functional* 30G Destructive 100G T ermination QC or PCB Nominal Coil Voltage Min. Operating Voltage Max. Operating Voltage Coil Resistance (Ω± 10%) at 23°C Single Coil (Latching) Dual Coil (Latching) 6Vdc 4.8Vdc 7.2Vdc 16Ω 2 x 8Ω 12Vdc 9.6Vdc 14.4Vdc 60Ω 2 x 30Ω 24Vdc 19.2Vdc 28.8Vdc 250Ω 2 x 125Ω 48Vdc 38.4Vdc 57.6Vdc 1000Ω 2 x 500Ω Coil Data Click here for glossary of terms Single Coil (Latching) D ual Coil (Latching) Coil Consumption 2.4W 4.8W P ulse Duration Min. 50ms, 100ms to 200ms recommended Min. 50ms, 100ms to 200ms recommended * Unit may change state but is still functional. 102012 K100 World Class Switching Solutions for Energy Management 100A P Owe R LAtC hi N g Re LAy » 2mm contact gap » UL Approval file number E178562 » VDE IEC 61810-1 Certified » RoHS compliant » Outline dimensions: (60.0 x 40.0 x 21.0)mm

Ordering Information

K100 A –D 012 Q P – 1A T R elay Series: T erminal Type: A: S ee drawings 1 X: C ustom design 2 Coil Type: S: Single c oil D ouble coil Coil Voltage 3: 6, 12, 24, 48 Vdc Coil Terminal Type: Q: Q uick connect R: PCB t erminals Coil Polarity: P = Positive N = Nega tive Contact Form: 1A: Form 1A – NO 1B: F orm 1B – NC Contact Material: T: AgSnO 2 A-Style Terminals Dimensional Drawings K100 Page 2 of 3 All dimensions in mm unless otherwise noted. For more information, please contact KG Technologies. 60.0 40.0 34.0 18.0 21.0 K100A 1 O ther standard terminal type drawings available upon request. 2 F or custom designs, please contact KG Technologies. Integrated shunts, flex-wire, copper extensions and br ass terminals available.

3 C oil voltage should be indicated in three digit format (6Vdc = 006)

Disclaimer: This data sheet is for reference only. All specifications are subject to change without prior notice. KG T echnologies, Inc. cannot predict every possible application for our relays. While we do our best to make our relays as versatile as possible, we highly recommend contacting our engineering team if you have any questions. KG T echnologies, Inc. is not responsible for malfunctioning relays when operated outside the specified parameters given in this data sheet. 102012 Wiring Diagrams 1: All relays are shipped in the “Closed” position. It is possible that during transit or final assembly the relay could change its state to the “Open” position. Therefore, it is recommended that all relays be set to the desired state of the relay via a power supply. 2: In order to maintain an “Open” or “Closed” state of the relay, the coil voltage should reach the rated voltage. The pulse width should be 50ms minimum to ensure a proper change of state. DO NOT energize both T1 and T3 at the same time on a Dual Coil or energize the coil for longer than 1 minute (damage to the coil could incur). 3: Relays without flex-wire cannot be tin-soldered. Moving or bending the terminals could cause damage to the internal structure of the relay. 4: For definitions of terms used in this data sheet, see glossary at www.kgtechnologies.net. Additional Application Notes Dual Coil S ingle Coil Dual Coil – Positive Polarity: Place a negative connection on T2. Then apply a 50ms positive pulse to T1 to open the contacts or to T3 to close the contacts. Dual Coil – Negative Polarity: Place a positive connection on T2. Then apply a 50ms negative pulse to T3 to open the contacts or to T1 to close the contacts. Single Coil: Place a negative connection on T1. Then apply a 50ms positive pulse to T3 to close the contacts. Reversing polarity will open the contacts. Application Notes Dual Coil Connection Single Coil Connection T1 T3 Positive Polarity Negative Polarity T1 T3 T1 T3 T1 T2 T3 Dual Coil T1 T3 Single Coil