JLLS_V01 LITTELFUSE | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 9
Technical content
Littelfuse.com/jlls, Littelfuse.com/jlln © 2020 Littelfuse, Inc. Rev: 0618201 of 9 POWR-GARD® Fuse CLASS T – JLLN / JLLS SERIES 300/600 V ac • Fast-Acting • 1–1200 A
Description
JLLN / JLLS series fuses are less than 1/3 the size of comparable Class R fuses and are typically used for short circuit protection of drives and surge sensitive components. When rated in accordance with the NEC*, JLLN / JLLS fuses provide fast-acting overload and short circuit protection for non-inductive circuits and equipment. Features/Benefits Extremely current-limiting Compact design 200 kA interrupting rating JLLN 35–60 amperes available with PCB mounts
Applications
Variable speed drive protection Power conversion devices (inverters, rectifiers, UPS) Power supplies and power distribution units Compact mains switches Recommended Fuse Holders LFT30 series LFT60 series LSCR series for 70–800 amperes Web Resources Download TC curves, CAD drawings and other technical information: Littelfuse.com/jlln Littelfuse.com/jlls AMPERE RATINGS 1 25 70 175 450 1100 2 30 80 200 500 1200 3 35 90 225 600 6 40 100 250 700 10 45 110 300 800 15 50 125 350 900* 20 60 150 400 1000 *J L L S onl y
Ordering Information
JLLS 6 T – – JLLS006 JLLS006.T JLLN 35 T – XL† JLLN035L JLLN035.TXL JLLN 40 T – XLSE† JLLN040LSE JLLN040.TXLSE JLLN 100 V XP – JLLN100P JLLN100.VXP † Option is available for JLLN 35–60 amperes only. Premium plating is standard Specifications JLLN Voltage Ratings Ac: 300 V Dc: 160 V (1–60 A)
125 V (70–1200 A)
Ampere Range 1–1200 A Interrupting Ratings Ac: 200 kA rms symmetrical Dc: 50 kA (1–30 A) 20 kA (35–1200 A) Approvals Ac: UL Standard 248-15, Class T UL Listed (File: E81895): 1–1200 A CSA Certified (File: LR29862): 1–600 A Dc: UL Listed (File: E81895): 1–1200 A Material 1–30 A: melamine body, bronze caps 35–1200 A: melamine body, copper caps Environmental RoHS Compliant Country of Origin Mexico JLLS Voltage Ratings Ac: 600 V Dc: 300 V Ampere Range 1–1200 A Interrupting Ratings Ac: 200 kA rms symmetrical Dc: 20 kA Approvals Ac: UL Standard 248-15, Class T UL Listed (File: E81895): 1–1200 A CSA Certified (File: LR29862): 1– 600 A Dc: Littelfuse self-certified Material 1–30 A: melamine body, copper caps 35–60 A: melamine body, bronze caps 70–1200 A: melamine body, copper caps Environmental RoHS Compliant Country of Origin Mexico Part Numbering System JLLN xxxx V — Package Quantity Series Options Amperage T = 10 (1–60 A) V = 5 (70 –100 A) X = 1 (110–1200 A) Blank = Standard Non-Plated XP = Premium Silver Plated XL = Leaded† XV = Vertical Mount† XLS = Solder Lead† XLSE = Solder Lead Extended† *NEC is a trademark of its respective owner.
Littelfuse.com/jlls, Littelfuse.com/jlln © 2020 Littelfuse, Inc. Rev: 0618202 of 9 POWR-GARD® Fuse CLASS T – JLLN / JLLS SERIES B C A F D F E A B C D G A C D Fig. 1 Fig. 2 Fig. 3 AMPERES REFER TO FIG. NO. SERIES DIMENSIONS INCHES ( mm) A B C D E F G 1–30 1 35–60 70–100 3 110 –200 3 225–400 3 450–600 3 700–800 3 900–1200 3 Dimensions Inches (mm)
Littelfuse.com/jlls, Littelfuse.com/jlln © 2020 Littelfuse, Inc. Rev: 0618203 of 9 POWR-GARD® Fuse CLASS T – JLLN / JLLS SERIES LSE T erminal Option CHICAGO, ILLINOIS 60631 3RD ANGLE PROJECTION
1 OL-JLLN000LSE
® REVISION DRWG NO. TITLE A DRW DATE GRAMS/PIECE FINISH GOOD WT MYORK 1/17/2018 MATL SPEC FINISH UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS, DIMENSIONS IN BRACKETS [ ] ARE INCHES DIMENSIONING AND DO NOT INCLUDE PLATING. TOLERANCING TO BE INTERPRETED IN ACCORDANCE WITH ANSI Y14.5M-1994 DENOTES CRITICAL CHARACTERISTICS. DENOTES CPK DIMENSIONS, -MINIMUM CPK VALUE DENOTES A CHARACTERISTIC THAT PROVIDES AN INDICATION OF PROCESS PERFORMANCE. PROCEDURE FOR MEASUREMENT AND TRACKING TO BE DEFINED IN LITTELFUSE INSPECTION INSTRUCTIONS. DENOTES CP DIMENSIONS, -MINIMUM CP VALUE MUST BE WITHIN THE DIMENSIONAL LIMITATIONS SHOWN ON DRAWING AND INITIALLY LOCATED TO ALLOW FOR MAXIMUM TOOL LIFE. CPK CP SHEET 1 OF 1 SCALE JLLN-LSE OUTLINE NTS REVISION REV DATE DESCRIPTION 1 1/17/18 PRELIMINARY DRAWING CREATED MRY 15.42 [0.607] REF 4.09 [0.161] REF 4.75 [0.187] REF 12.70 [0.500] REF 14.22 [0.560] REF 12.95 - 0.00 0.13+ 0.510 - 0.000 0.005+[ ] 24.49 [0.964] MAX 21.84 [0.860] MIN 1.32 [0.052] REF 4.19 - 0.00 0.13+ 0.165 - 0.000 0.005+ [ ] PAD LAYOUT 4.19 [0.165] REF 22.28 [0.877] REF 23.98 [0.944] REF LEAD-FREE SOLDERING PROFILE: PRE-HEAT: ABOVE 130°C FOR 75 SECONDS MAX. REFLOW: 278°C FOR 8 SECONDS MAX. TIME: 250 SECONDS MAX. MAX. TEMP: 280°C PRELIMINARY Solder JLLN-XLS Leaded JLLN-XL Vertical Mount JLLN-XV 4.95 [0.195] REF 44.81 [1.764] 42.93 [1.690] MIN 45.57 [1.794] MAX 4.19 - 0.00 0.13+ 0.165 - 0.000 0.005+ [ ] 1.32 [0.052] REF 12.95 - 0.00 0.13+ 0.510 - 0.000 0.005+ [ ] PAD LAYOUT 12.70±0.25 0.500±0.010[ ] 34.54 [1.360] 29.72 [1.170] PCB Mounting Options (JLLN 35–60 A Only) CHICAGO, ILLINOIS 60631 3RD ANGLE PROJECTION Littelfuse ® REVISION DRWG NO. TITLE DRW DATE GRAMS/PIECE FINISH GOOD WT MATL SPEC FINISH UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS, DIMENSIONS IN BRACKETS [ ] ARE INCHES DIMENSIONING AND DO NOT INCLUDE PLATING. TOLERANCING TO BE INTERPRETED IN ACCORDANCE WITH ANSI Y14.5M-1994 DENOTES CRITICAL CHARACTERISTICS. DENOTES CPK DIMENSIONS, -MINIMUM CPK VALUE DENOTES A CHARACTERISTIC THAT PROVIDES AN INDICATION OF PROCESS PERFORMANCE. PROCEDURE FOR MEASUREMENT AND TRACKING TO BE DEFINED IN LITTELFUSE INSPECTION INSTRUCTIONS. DENOTES CP DIMENSIONS, -MINIMUM CP VALUE MUST BE WITHIN THE DIMENSIONAL LIMITATIONS SHOWN ON DRAWING AND INITIALLY LOCATED TO ALLOW FOR MAXIMUM TOOL LIFE. CPK CP SHEET 1 OF 1 SCALE B OL-JLLN000V B myork 03/27/2017 JLLN-V OUTLINE & PAD LAYOUT NTS REVISION REV DATE DESCRIPTION A 3/29/17 517351GCP - RELEASE MRY B 8/9/19 521072ECP/D - ADD LEAD DIMENSIONS MRY PAD LAYOUT CHICAGO, ILLINOIS 60631 3RD ANGLE PROJECTION Littelfuse ® REVISION DRWG NO. TITLE DRW DATE GRAMS/PIECE FINISH GOOD WT MATL SPEC FINISH UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS, DIMENSIONS IN BRACKETS [ ] ARE INCHES DIMENSIONING AND DO NOT INCLUDE PLATING. TOLERANCING TO BE INTERPRETED IN ACCORDANCE WITH ANSI Y14.5M-1994 DENOTES CRITICAL CHARACTERISTICS. DENOTES CPK DIMENSIONS, -MINIMUM CPK VALUE DENOTES A CHARACTERISTIC THAT PROVIDES AN INDICATION OF PROCESS PERFORMANCE. PROCEDURE FOR MEASUREMENT AND TRACKING TO BE DEFINED IN LITTELFUSE INSPECTION INSTRUCTIONS. DENOTES CP DIMENSIONS, -MINIMUM CP VALUE MUST BE WITHIN THE DIMENSIONAL LIMITATIONS SHOWN ON DRAWING AND INITIALLY LOCATED TO ALLOW FOR MAXIMUM TOOL LIFE. CPK CP SHEET 1 OF 1 SCALE B OL-JLLN000V B myork 03/27/2017 JLLN-V OUTLINE & PAD LAYOUT NTS REVISION REV DATE DESCRIPTION A 3/29/17 517351GCP - RELEASE MRY B 8/9/19 521072ECP/D - ADD LEAD DIMENSIONS MRY PAD LAYOUT CHICAGO, ILLINOIS 60631 3RD ANGLE PROJECTION ® REVISION DRWG NO. TITLE A DRW DATE GRAMS/PIECE FINISH GOOD WT MYORK 1/17/2018 MATL SPEC FINISH UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS, DIMENSIONS IN BRACKETS [ ] ARE INCHES DIMENSIONING AND DO NOT INCLUDE PLATING. TOLERANCING TO BE INTERPRETED IN ACCORDANCE WITH ANSI Y14.5M-1994 DENOTES CRITICAL CHARACTERISTICS. DENOTES CPK DIMENSIONS, -MINIMUM CPK VALUE DENOTES A CHARACTERISTIC THAT PROVIDES AN INDICATION OF PROCESS PERFORMANCE. PROCEDURE FOR MEASUREMENT AND TRACKING TO BE DEFINED IN LITTELFUSE INSPECTION INSTRUCTIONS. DENOTES CP DIMENSIONS, -MINIMUM CP VALUE MUST BE WITHIN THE DIMENSIONAL LIMITATIONS SHOWN ON DRAWING AND INITIALLY LOCATED TO ALLOW FOR MAXIMUM TOOL LIFE. CPK CP SHEET 1 OF 1 SCALE JLLN-LSE OUTLINE NTS REVISION REV DATE DESCRIPTION 1 1/17/18 PRELIMINARY DRAWING CREATED MRY 15.42 [0.607] REF 4.09 [0.161] REF 4.75 [0.187] REF 12.70 [0.500] REF 14.22 [0.560] REF 12.95 - 0.00 0.13+ 0.510 - 0.000 0.005+[ ] 24.49 [0.964] MAX 21.84 [0.860] MIN 1.32 [0.052] REF 4.19 - 0.00 0.13+ 0.165 - 0.000 0.005+ [ ] PAD LAYOUT 4.19 [0.165] REF 22.28 [0.877] REF 23.98 [0.944] REF LEAD-FREE SOLDERING PROFILE: PRE-HEAT: ABOVE 130°C FOR 75 SECONDS MAX. REFLOW: 278°C FOR 8 SECONDS MAX. TIME: 250 SECONDS MAX. MAX. TEMP: 280°C PRELIMINARY
Littelfuse.com/jlls, Littelfuse.com/jlln © 2020 Littelfuse, Inc. Rev: 0618204 of 9 POWR-GARD® Fuse CLASS T – JLLN / JLLS SERIES - DATA GENERATED IN EXCEL - 1000 900 800 700 600 500 400 300 200 100 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000 900 800 700 600 500 400 300 200 100 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000 900 800 700 600 500 400 300 200 100 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 1000 900 800 700 600 500 400 300 200 100 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 - 1A - 2A - 3A - 6A - 10A BASIS FOR DATA: TEST VOLTAGE: TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 1/21/14 A
2 OF 8
Time Current Curve JLLN (1–10 A) - DATA GENERATED IN EXCEL - 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 10000090000 80000 70000 60000 50000 40000 30000 20000 100009000 8000 7000 6000 5000 4000 3000 2000 1000900 800 700 600 500 400 300 200 10090 - 15A - 20A - 25A - 30A BASIS FOR DATA: TEST VOLTAGE: TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 1/21/14 A
3 OF 8
- DATA GENERATED IN EXCEL - 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 10000090000 80000 70000 60000 50000 40000 30000 20000 100009000 8000 7000 6000 5000 4000 3000 2000 1000900 800 700 600 500 400 300 200 10090 - 35A - 40A - 45A - 50A - 60A BASIS FOR DATA: TEST VOLTAGE: TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 1/21/14 A
4 OF 8
- DATA GENERATED IN EXCEL - 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 10000090000 80000 70000 60000 50000 40000 30000 20000 100009000 8000 7000 6000 5000 4000 3000 2000 1000900 800 700 600 500 400 300 200 10090 - 70A - 80A - 90A - 100A BASIS FOR DATA: TEST VOLTAGE: TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 1/21/14 A
5 OF 8
Time Current Curve JLLN (15–30 A) Time Current Curve JLLN (35–60 A) Time Current Curve JLLN (70–100 A)
Littelfuse.com/jlls, Littelfuse.com/jlln © 2020 Littelfuse, Inc. Rev: 0618205 of 9 POWR-GARD® Fuse CLASS T – JLLN / JLLS SERIES - DATA GENERATED IN EXCEL - 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 10000090000 80000 70000 60000 50000 40000 30000 20000 100009000 8000 7000 6000 5000 4000 3000 2000 1000900 800 700 600 500 400 300 200 10090 - 110A - 125A - 150A - 175A - 200A BASIS FOR DATA: TEST VOLTAGE: TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 1/21/14 A
6 OF 8
- DATA GENERATED IN EXCEL - 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 10000090000 80000 70000 60000 50000 40000 30000 20000 100009000 8000 7000 6000 5000 4000 3000 2000 1000900 800 700 600 500 400 300 200 10090 - 225A - 250A - 300A - 350A - 400A BASIS FOR DATA: TEST VOLTAGE: TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 1/21/14 A
7 OF 8
- DATA GENERATED IN EXCEL - 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 10000090000 80000 70000 60000 50000 40000 30000 20000 100009000 8000 7000 6000 5000 4000 3000 2000 1000900 800 700 600 500 400 300 200 10090 - 450A - 500A - 600A - 700A - 800A - 1000A - 1100A - 1200A BASIS FOR DATA: TEST VOLTAGE: TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 1/21/14 A
8 OF 8
Time Current Curve JLLN (110–200 A) Time Current Curve JLLN (225–400 A) Time Current Curve JLLN (450–1200 A)
Littelfuse.com/jlls, Littelfuse.com/jlln © 2020 Littelfuse, Inc. Rev: 0618206 of 9 POWR-GARD® Fuse CLASS T – JLLN / JLLS SERIES - DATA GENERATED IN EXCEL - 1000 900 800 700 600 500 400 300 200 100 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000 900 800 700 600 500 400 300 200 100 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000 900 800 700 600 500 400 300 200 100 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 1000 900 800 700 600 500 400 300 200 100 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 - 1A - 2A - 3A - 6A - 15A - 20A - 25A - 30A - 10A CURRENT IN AMPERES TIME IN SECONDS BASIS FOR DATA: TEST VOLTAGE: TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 01/21/14 A Time Current Curve JLLS (1–30 A) - DATA GENERATED IN EXCEL - 1000 900 800 700 600 500 400 300 200 100 90 10 9 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000 900 800 700 600 500 400 300 200 100 90 10 9 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 90 - 35A - 40A - 45A - 50A - 60A CURRENT IN AMPERES TIME IN SECONDS BASIS FOR DATA: TEST VOLTAGE: TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 01/21/14 A
- DATA GENERATED IN EXCEL - 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 10000090000 80000 70000 60000 50000 40000 30000 20000 100009000 8000 7000 6000 5000 4000 3000 2000 1000900 800 700 600 500 400 300 200 10090 - 70A - 80A - 90A - 100A CURRENT IN AMPERES TIME IN SECONDS BASIS FOR DATA: TEST VOLTAGE: TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 03/13/2014 A
- DATA GENERATED IN EXCEL - 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000900 800 700 600 500 400 300 200 10090 109 10.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.10.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 10000090000 80000 70000 60000 50000 40000 30000 20000 100009000 8000 7000 6000 5000 4000 3000 2000 1000900 800 700 600 500 400 300 200 10090 - 110A - 125A - 150A - 175A - 200A CURRENT IN AMPERES TIME IN SECONDS BASIS FOR DATA: TEST VOLTAGE: TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 03/13/2014 A
Time Current Curve JLLS (35–60 A) Time Current Curve JLLS (70–100 A) Time Current Curve JLLS (110–200 A)
Littelfuse.com/jlls, Littelfuse.com/jlln © 2020 Littelfuse, Inc. Rev: 0618207 of 9 POWR-GARD® Fuse CLASS T – JLLN / JLLS SERIES - DATA GENERATED IN EXCEL - 1000 900 800 700 600 500 400 300 200 100 90 10 9 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000 900 800 700 600 500 400 300 200 100 90 10 9 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 90 - 225A - 250A - 300A - 350A - 400A CURRENT IN AMPERES TIME IN SECONDS BASIS FOR DATA: TEST VOLTAGE: TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 01/21/14 A
- DATA GENERATED IN EXCEL - 1000 900 800 700 600 500 400 300 200 100 90 10 9 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000 900 800 700 600 500 400 300 200 100 90 10 9 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 90 - 450A - 500A - 600A CURRENT IN AMPERES TIME IN SECONDS BASIS FOR DATA: TEST VOLTAGE: TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 01/21/14 A
- DATA GENERATED IN EXCEL - 1000 900 800 700 600 500 400 300 200 100 90 10 9 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 1000 900 800 700 600 500 400 300 200 100 90 10 9 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 100000 90000 80000 70000 60000 50000 40000 30000 20000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 900 800 700 600 500 400 300 200 100 90 - 700A - 800A - 900A - 1000A - 1100A - 1200A BASIS FOR DATA: TEST VOLTAGE: TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET TIME CURRENT CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 01/21/14 A
Time Current Curve JLLS (225–400A) Time Current Curve JLLS (450–600A) Time Current Curve JLLS (700–1200A)
Littelfuse.com/jlls, Littelfuse.com/jlln © 2020 Littelfuse, Inc. Rev: 0618208 of 9 POWR-GARD® Fuse CLASS T – JLLN / JLLS SERIES SHORT CIRCUIT CURRENT* APPARENT RMS SYMMETRICAL CURRENT FOR VARIOUS FUSE RATINGS
30 A 60 A 100 A 200 A 400 A 600 A 800 A 1200 A
5,000 700 775 1,100 1,650 3,500 4,000 5,000 5,000 10,000 900 1,000 1,400 2,100 4,400 5,100 6,750 8,250 15,000 1,000 1,100 1,600 2,400 5,000 5,900 7,75 0 10,000 20,000 1,100 1,250 1,800 2,700 5,500 6,500 8,750 11,000 25,000 1,230 1,300 1,950 2,900 6,000 7 ,000 9,500 12,000 30,000 1,300 1,475 2,050 3,100 6,400 7 ,500 10,000 12,500 35,000 1,330 1,575 2,150 3,300 6,750 7,75 0 10,500 13,500 40,000 1,430 1,600 2,300 3,500 7 ,000 8,000 11,000 14,000 50,000 1,500 1,750 2,400 3,700 7 ,500 8,750 12,000 15,000 60,000 1,700 1,900 2,700 4,000 8,000 9,500 12,500 16,000 80,000 1,850 2,100 2,800 4,400 9,000 10,500 14,000 17 ,500 100,000 2,000 2,250 3,150 4,800 9,750 11,500 15,000 18,500 150,000 2,300 2,600 3,600 5,500 11,000 13,000 17 ,500 22,000 200,000 2,600 2,800 3,900 6,000 12,000 14,500 19,500 24,000 *Prospective RMS Symmetrical Amperes Short-Circuit Current Note: Data Derived from Peak Let-Thru Curves - DATA GENERATED IN EXCEL - 100 1,000 10,000 100,000 1,000,000 100 1,000 10,000 100,000 PEAK LET- THRU IN AMPERES AVAILABLE FAULT CURRENT SYMMETRICAL R.M.S. AMPERES 1200A - 800A - 600A - 400A - 200A - 100A - 60A - 30A - BASIS FOR DATA: TEST VOLTAGE: 300V TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET PEAK LET-THRU CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 01/21/2014 A
2 OF 2
Peak Let-Thru Curve and Current-Limiting Effects of JLLN (300 V) Fuses
Littelfuse.com/jlls, Littelfuse.com/jlln © 2020 Littelfuse, Inc. Rev: 0618209 of 9 POWR-GARD® Fuse CLASS T – JLLN / JLLS SERIES - DATA GENERATED IN EXCEL - 100 1,000 10,000 100,000 1,000,000 100 1,000 10,000 100,000 PEAK LET- THRU IN AMPERES AVAILABLE FAULT CURRENT SYMMETRICAL R.M.S. AMPERES 800A - 600A - 500A - 400A - 200A - 100A - 60A - 30A - BASIS FOR DATA: TEST VOLTAGE: 600V TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET PEAK LET-THRU CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 01/28/2014 B
2 OF 3
- DATA GENERATED IN EXCEL - 1,000 10,000 100,000 1,000,000 1,000 10,000 100,000 PEAK LET- THRU IN AMPERES AVAILABLE FAULT CURRENT SYMMETRICAL R.M.S. AMPERES 1200A - 1100A - 1000A - 900A - BASIS FOR DATA: TEST VOLTAGE: 600V TIME CONSTANT/POWER FACTOR: FUSE CATALOG NUMBER: DRAWN BY: DATE: REVISION: DRAWING NO.: SHEET PEAK LET-THRU CHARACTERISTIC CURVES LITTELFUSE, INC. CHICAGO, IL. USA LLL 01/28/2014 A
3 OF 3
Peak Let-Thru Curve and Current-Limiting Effects of JLLS (600 V) Fuses Disclaimer Notice - Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own SHORT CIRCUIT CURRENT* APPARENT RMS SYMMETRICAL CURRENT FOR VARIOUS FUSE RATINGS 5,000 750 1,225 1,810 2,500 4,600 5,000 5,000 5,000 10,000 945 1,525 2,300 3,150 6,000 8,500 9,400 10,000 15,000 1,050 1,700 2,610 3,600 6,600 9,750 10,500 13,000 20,000 1,150 1,900 2,900 3,950 7,25 0 10,500 11,000 14,750 25,000 1,300 2,050 3,100 4,250 8,000 11,500 12,500 15,500 30,000 1,375 2,150 3,300 4,500 8,250 12,000 13,750 16,500 35,000 1,400 2,250 3,500 4,750 8,500 13,000 14,000 17 ,000 40,000 1,425 2,400 3,650 4,950 8,700 14,000 14,750 18,000 50,000 1,600 2,450 3,900 5,350 9,500 14,500 16,000 20,000 60,000 1,650 2,625 4,150 5,650 10,000 15,500 17,30 0 21,000 80,000 1,825 2,800 4,570 6,250 11,000 17 ,000 18,750 23,000 100,000 2,000 3,100 4,950 6,700 12,000 18,000 20,000 25,000 150,000 2,250 3,400 5,650 7,70 0 13,000 21,000 23,000 28,500 200,000 2,450 3,800 6,200 8,450 15,000 23,000 25,000 31,000 *Prospective RMS Symmetrical Amperes Short-Circuit Current Note: Data Derived from Peak Let-Thru Curves