JK1APF-12V NAIS | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
15.7 .618 .43321.4 .843
FEATURES
- Compact & Slim design: 11.0 mm (length) 21.4 mm (width) 15.7 mm (height) (.433 .843 .618 inch)
- High capacity type (8 A) available
- Surge resistance: Min. 8,000 V between contact and coil
- High sensitivity: 200 mW nominal operating power
- Sealed type available
- VDE, TÜV, SEMKO also approved SPECIFICATIONS Contact Coil Remarks * Specifications will vary with foreign standards certification ratings. Measurement at same location as "Initial breakdown voltage" section Detection current: 10 mA Wave is standard shock voltage of 1.2 m s according to JEC-212-1981 Excluding contact bounce time Half-wave pulse of sine wave: 11ms; detection time: 10 m s Half-wave pulse of sine wave: 6ms Detection time: 10 m s Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61). Characteristics Type Standard type High capacity type Arrangement 1 Form A Initial contact resistance, max. (By voltage drop 6 V DC 1 A) 100 m W Contact material Silver alloy Rating (resistive load) Nominal switching capacity
3 A 30 V DC
3 A 125 V AC
5 A 30 V DC
8 A 125 V AC
Max. switching power 90 W, 500 VA 150 W, 1,250 V A Max. switching voltage 250 V AC, 110 V DC (0.3 A) Max. switching current 3 A 8 A Expected life (min. operations) Mechanical (at 180 cpm) 5 Electrical (at 20 cpm) (at rated load) 10 Nominal operating power Standard and high capacity type 200 mW Max. operating speed 20 cpm Initial insulation resistance* Min. 100 M W at 500 V DC Initial breakdown voltage* Between open contacts 750 Vrms for 1 min. Between contact and coil 2,000 Vrms for 1 min. Surge voltage between contact and coil* Min. 8,000 V Operate time* (at nominal voltage) Approx. 4 ms Release time* (at nominal voltage) (without diode) Approx. 2 ms Temperature rise (ambient temperature: 70 Max. 45 C with nominal coil voltage and at maximum allowable contact current Shock resistance Functional* Min. 98 m/s {10 G} Destructive* Min. 980 m/s {100 G} Vibration resistance Functional* 10 to 55 Hz at double amplitude of 1.6 mm Destructive 10 to 55 Hz at double amplitude of 2 mm Conditions for operation, transport and storage* (Not freezing and condensing at low temperature) Ambient temp. –40 C to +70 C –40 F to +158 F Humidity 5 to 85% R.H. Unit weight Approx. 7 g .25 oz TYPICAL APPLICATIONS
- Home appliances Microwave ovens, Air conditioners
- Office equipment Photocopiers, Facsimiles
- Industrial machines NC machines
ORDERING INFORMATION
Notes: UL/CSA, VDE approved type is standard. 1. For TV-5 rated type, add sufix “-TV”. 1. For detailed specifications, please consult us. 2. Standard packing: Carton: 100 pcs.; Case: 500 pcs. Ex. JK 1a P F 12 V Contact capacity Nil: Standard 3 A P: High capacity Nil: Sealed type F: Flux-resis- tant type 24, 48 V Protectiive constructiion Coil voltage (DC)
- Standard type (3 A) 2. High capacity type (8 A) Coil voltage, V DC Part No. Sealed type Flux-resistant type
3 JK1a-3V JK1aF-3V
5 JK1a-5V JK1aF-5V
6 JK1a-6V JK1aF-6V
9 JK1a-9V JK1aF-9V
12 JK1a-12V JK1aF-12V
18 JK1a-18V JK1aF-18V
24 JK1a-24V JK1aF-24V
48 JK1a-48V JK1aF-48V
Coil voltage, V DC Part No. Sealed type Flux-resistant type
3 JK1aP-3V JK1aPF-3V
5 JK1aP-5V JK1aPF-5V
6 JK1aP-6V JK1aPF-6V
9 JK1aP-9V JK1aPF-9V
12 JK1aP-12V JK1aPF-12V
18 JK1aP-18V JK1aPF-18V
24 JK1aP-24V JK1aPF-24V
48 JK1aP-48V JK1aPF-48V
COIL DATA (at 20 C 68 Nominal voltage, V DC Pick-up voltage V DC (max.) Drop-out voltage, V DC (min.) Coil resistance W 10%) Nominal operating current, mA ( 10%) Nominal operating power, mW Max. allowable voltage at 70 V DC 3 2.4 0.15 45 67 200 3.9 5 4.0 0.25 125 40 200 6.5 6 4.8 0.3 180 33 200 7.8 9 7.2 0.45 405 22 200 11.7 12 9.6 0.6 720 17 200 15.6 18 14.4 0.9 1,620 11 200 23.4 24 19.2 1.2 2,880 8.3 200 31.2 48 38.4 2.4 11,520 4.2 200 62.4 DIMENSIONS 15.4 .606 0.3 .012 .157 .433 7.62 .300 21.4 .843 1COM N.O. 2.54 .100 1.6 .063 15.24 .600 Dimension: Gener al tolerance Max. 1mm .039 inch 0.2 .008 1 to 5mm .039 to .197 inch 0.3 .012 Min. 5mm .197 inch 0.4 .016 PC board pattern (Copper-side view) Tolerance: 0.1 .004 2-0.9 dia. 2-.035 dia. 2-1.3 dia. 2-.051 dia. mm inch REFERENCE DATA 1-(1). Maximum value for switching capacity (Standard type) 1-(2). Maximum value for switching capacity (High capacity type) 2. Operate/release time Contact voltage, V Contact current, A 100 100 250 AC resistive load Contact voltage, V Contact current, A 108 100 100 250 AC resistive load Coil applied voltage, %V Operate/release time, ms 80 100 120 140 160 180 Max. Max. Min.x– Min. Operate time Release time
- Coil temperature rise (High capacity type) Measured portion: Inside the coil Contact current: 8 A 4. Ambient temperature characteristics (High capacity type) Contact current: 8 A 80 120 140 160 180100 Coil applied voltage, %V Temperature rise, deg. Ambient temperature 25°C Ambient temperature 70°C 20 40 60 80 100 200 300 Ambient temperature, °C Voltage, %V Allowable ambient temperatures against % coil voltage (max. inside the coil temperature set as 115°C 239°F) Pick-up voltage with a hot-start condition of 100%V on the coil Pick-up voltage 5.-(1) Life curve (Standard type) Operation frequency: 20 times/min. (ON/OFF = 1.5s:1.5s) Ambient temperature: Room temperature 5.-(2) Life curve (High capacity type) Operation frequency: 20 times/min. (ON/OFF = 1.5s:1.5s) Ambient temperature: Room temperature 100 102 3 4 125V AC resistive load 250V AC resistive load Contact current, A Life, ·104 100 2345 67 89 125V AC resistive load 250V AC resistive load Contact current, A Life, ·104 For Cautions for Use, see Relay Technical Information (Page 48 to 76). 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog