Edition • 2023-07-21T16:26:47+02:00 Rotation speed monitor 1-channel IM21-14EX-CDTRI The rotation speed monitor IM21-14EX- CDTRI monitors frequencies, rotation speeds and pulse trains of rotating motor, gear or tur- bine parts according to over or undershoot of adjusted limit values. The current value is indi- cated on a display on the front of the device. Intrinsically safe sensors acc. to EN 60947-5-6 (NAMUR) can be connected. De- pending on the settings, the line is monitored for wire-break and/or short-circuit. In the event of an input circuit error the relays drop out, the transistor is blocked and the Pwr LED changes to red. The device can be parametrized and config- ured via PC (FDT / DTM). For this, connect the device to the PC via the 3.5 mm jack on the front (the matching transmission cable IM-PROG III can be ordered separately from TURCK). In addition, a basic scope of pa- rameters can be set via buttons and display on the front as well as via the HART capable power interface At each of the two relay outputs a predefined limit value can be monitored. The two relays also monitor overshoot/undershoot of window limits. The transistor output can also be used as a pulse divider. The measured value is per- manently written to a ring buffer with space for 8000 values. The writing process is stopped with a predefined trigger event, like for ex- ample "excess of limit value". After that, the stored signal sequence can be read out. A switching hysteresis is defined by setting a switch-on and off point. A switch-off delay can also be set to avoid shut down due to sudden frequency hops. ■ Monitoring of limit values and ranges ac- cording to over and underrange ■ Operating range 0.06…600,000 min ■ Pulse output Ex [ic Gc] II C/II B ■ Parameterized via PC (FDT/DTM), front- panel switch or HART ■ Ring buffer for up to 8000 measured val- ues ■ Display ■ Complete galvanic isolation ■ Input reverse-polarity protected ■ ATEX, IECEx, CFMUS, TR CU, NEPSI, TIIS, Kosha ■ Installation in zone 2

Edition • 2023-07-21T16:26:47+02:00 Type IM21-14EX-CDTRI ID 7505651 Nominal voltage Universal voltage supply unit Operating voltage 20…250 VAC Frequency 40…70 Hz Operating voltage 20…125 VDC Power consumption ð 3 W Monitoring range/Setting range ð 0.06…600000 min Max. input frequency 600000 min Pulse time ï 0.02 ms Pulse pause ï 0.02 ms NAMUR input NAMUR EN 60947-5-6 No-load voltage 8.2 VDC Short-circuit current 8.2 mA Input resistance 1 kò Cable resistance ð 50 ò Switch-on threshold 1.75 mA Switch-off threshold 1.55 mA Wire breakage threshold ð 0.06 mA Short-circuit threshold ï 6.4 mA Output circuits Output current 0/4…20 mA Load resistance current output ð 0.6 kò Fault current 0 / 22 mA adjustable Output circuits (digital) 2 x relays (NO) Output switching voltage relay ð 30 VDC / ð 250 VAC Switching current per output ð 2 A Switching capacity per output ð 500 VA/60 W Switching frequency ð 10 Hz Semicondutor output circuit(s) Output circuits (digital) 1 x transistor (potential-free, short-circuit proof) Switching voltage ð 30 VDC Switching current per output ð 0.05 A Switching frequency ð 10000 Hz Voltage drop ð 2.5 V Feed-forward pulse output Voltage ð 30 V Current ð 10 mA Response characteristic Measuring accuracy (including linearity, hysteresis and repeatability) ð 0.05 % of full scale Reference temperature 23 °C Temperature drift analog output 0.0025 %/K Galvanic isolation Test voltage 2.5 kV RMS Dimensions Output relay – Load curve Output relay – Electrical lifetime

Edition • 2023-07-21T16:26:47+02:00 Important note For Ex-applications the values specified in the corre- sponding Ex certificates (ATEX, IECEx, UL, etc.) ap- ply. Ex approval acc. to conformity certificate IBExU 07 ATEX 1132 Application area II (1) G, II (1) D Ignition protection category [Ex ia Ga] IIC , [Ex ia Da] IIIC Ex approval acc. to conformity certificate IBExU 07 ATEX B010 X Application area II 3 G Ignition protection type Ex nA nC [ic Gc] IIC/IIB T4 Gc Characteristic linear Displays/Operating elements Operational readiness Green Pulse input Yellow Error indication red Mechanical data Protection class IP20 Flammability class acc. to UL 94 V-0 Ambient temperature -25…+70 °C -25 ... +60 °C für FM Storage temperature -40…+80 °C Dimensions 104 x 27 x 110 mm Weight 249 g Mounting instructions DIN rail (NS35) or panel Housing material Polycarbonate/ABS Electrical connection 4 × 5-pin removable terminal blocks, reverse polarity protected, screw terminal Terminal cross-section 1 × 2.5 mm²/2 × 1.5 mm² Tightening torque 0.5 Nm

Edition • 2023-07-21T16:26:47+02:00 Accessories Type code Ident-No. Dimension drawing IM-CC-5X2BU/2BK 7504031 Cage clamp terminals for IM modules (Ex-devices with 27 mm overall width); includes: 2 pcs. 5-pin blue terminals and 2 pcs. 5-pin black terminals. WM1 WIDER- STANDSMODUL

0912101 The resistor module WM1 meets the requirements for line

monitoring between a mechanical contact and a TURCK signal processor. The input circuit of the signal processor is designed for sensors acc. to EN60947-5-6 (NAMUR) and equipped with a wire-break and short-circuit monitoring func- tion. IM-PROG III 7525111 USB-compatible programming adapter for the FDT/DTM- based parametrization of HART-capable Turck devices; gal- vanic separation between the device to be parametrized and the PC