IM07TS MACOM | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 10

Technical content

2 pole telecom/signal relay, polarized Through Hole Types (THT), standard version with 5.08 mm, narrow version with 3.2 mm between the terminal rows or Surface Mount Type (SMT) Relay types: non-latching with 1 coil latching with 1 coil

Features

  • Telecom/signal relay (dry circuit, test access, ringing) - Slim line10 x 6 mm, 0.39 x 0.24 inch - Low profile 5.65 mm, 0.222 inch - Minimum board-space 60 mm - Switching current 2 A - 2 changeover contacts (2 form C / DPDT) - Bifurcated contacts, gold plated - High sensitivity results in low nominal power consumption 140 mW for non latching 100 mW for latching version - High surge capability (1.2/50 µs and 10/700 µs) meets Bellcore GR 1089, FCC Part 68 and ITU-T K20 ³1500 V between open contacts ³ 2500 V between coil and contacts - High mechanical shock resistance up to 300 G functional up to 500 G survival Typical applications: - Communications equipment Linecard application – analog, ISDN, xDSL, PABX Voice over IP - Office and business equipment - Measurement and control equipment - Consumer electronics Set top boxes, HiFi - Medical equipment Options: Surge capability ³ 2500 V between open contacts IM Relay Insulation category: Supplementary insulation according IEC/EN 60950 and UL 1950 Working voltage £ 300 Vrms Mains supply voltage SMT: 250 Vrms THT: 200 Vrms Repetitive peak voltage 2500 V Pollution degree: External: 2 Internal: 1 Flammability classification: V-0 Maximum operating temperature: 85°C CSA-C22.2 No. 14-95 File No. 169679-1079886 CSA-C22.2 No. 950-95 UL 508 File No. E111441 UL 1950 3rd ed. QC 160501-CH0001 IEC/EN60950 IEC Ref. Cert. No. 1176 CECC 16501-003

View onto the component side of the PCB (top view) Terminal assignment Relay - top view Non-latching type, not energized condition Dimensions IM THT IM THT IM SMT IM SMT Standard Narrow Gull Wings J-Legs mm inch mm inch mm inch T 3.2 0.125 3.2 0.125 N/A N/A N/A N/A SMT Version Gull Wings J Legs Solder pad layout View onto the component side of the PCB (top view) Gull Wings J Legs Ø min. 0.75 Latching type, 1 coil reset condition Standard version Narrow version Standard version Narrow version

1.5 1.13 3.4 0.15 140 16 IM00 3 2.1 6.8 0.30 140 64 IM01 4.5 3.15 10.3 0.45 140 145 IM02 5 3.5 11.4 0.50 140 178 IM03 6 4.2 13.7 0.60 140 257 IM04 9 6.3 20.4 0.90 140 574 IM05 12 8.4 27.3 1.20 140 1028 IM06 24 16.8 45.6 2.40 200 2880 IM07 Coil Data (values at 23°C) Nominal Operate/set voltage range Release/ Nominal power Resistance Relay code voltage reset voltage consumption Unom Minimum Maximum Minimum voltage UI voltage UII Vdc Vdc Vdc Vdc mW W / ± 10 % non-latching 1 coil latching 1 coil 1.5 1.13 4.1 - 1.13 100 23 IM40 3 2.25 8.1 - 2.25 100 90 IM41 4.5 3.38 12.1 - 3.38 100 203 IM42 5 3.75 13.5 - 3.75 100 250 IM43 6 4.5 16.2 - 4.50 100 360 IM44 9 6.75 24.2 - 6.75 100 810 IM45 12 9.00 32.3 - 9.00 100 1440 IM46 24 18.00 41.9 - 18.00 200 2880 IM47 Further coil versions are available on request. IM Relay Ambient temperature tamb [°C] UI = Minimum voltage at 23° C after pre-energizing with nominal voltage without contact current UII = Maximum continous voltage at 23° The operating voltage limits UI and UII depend on the temperature according to the formula: UI tamb =K I · UI 23° C and UII tamb =K Il · UIl 23° C tamb = Ambient temperature UI tamb = Minimum voltage at ambient temperature, t amb UII tamb = Maximum voltage at ambient temperature, t amb kI, kII = Factors (dependent on temperature), see diagram

Number of contacts and type Contact assembly Contact material Limiting continuous current at max. ambient temperature Maximum switching current Maximum swichting voltage Maximum switching capacity Thermoelectric potential Initial contact resistance / measuring condition: 10 mA / 20 mV Electrical endurance at contact application 0 cable load open end Resistive load at 125Vdc / 0.24 A - 30 W at 220 Vdc / 0.27 A - 60 W at 250 Vac / 0.25 A - 62.5 VA at 30 Vdc / 1 A - 30 W at 30 Vdc / 2 A - 60 W Mechanical endurance UL/CSA ratings 2 changeover contacts Bifurcated contacts Palladium-ruthenium, gold-covered 2 A 2 A

220 Vdc

250 Vac

60 W, 62.5 VA < 10 mV < 50 mW min. 2.5 x 10 6 operations min. 2.0 x 10 6 operations min. 5 x 105 operations min. 1 x 105 operations min. 1 x 105 operations min. 5 x 105 operations min. 1 x 105 operations typ. 108 operations

30 Vdc / 2 A

220 Vdc / 0.27 A 120 Vdc / 0.5 A 250 Vac / 0.25 A Capacitance between coil and contacts between adjacent contact sets between open contacts RF Characteristics Isolation at 100 / 900 MHz Insertion loss at 100 / 900 MHz V.S.W.R. at 100 / 900 MHz max. 2 pF max. 2 pF max. 1 pF - 37.0 dB / - 18.8 dB - 0.03 dB / - 0.33 dB 1.06 / 1.49 High Frequency Data * High Dielectric Version „C“ Insulation Insulation resistance at 500 VDC Dielectric test voltage (1 min) between coil and contacts between adjacent contact sets between open contacts Surge voltage resistance according to Bellcore TR-NWT-001089 (2 / 10 ms) between coil and contacts between adjacent contact sets between open contacts according to FCC 68 (10 / 160 ms) between coil and contacts between adjacent contact sets between open contacts > 10

9 W > 109 W

1800 Vrms 1800 Vrms

1000 Vrms 1800 Vrms

1000 Vrms 1500 Vrms

2500 V 2500 V

1500 V 2500 V

Standard Version High Dielectric Version

Operate time at Unom typ. / max. Reset time (latching) at Unom , typ. / max. Release time without diode in parallel (non-latching), typ. / max. Release time with diode in parallel (non-latching), typ. / max. Bounce time at closing contact, typ. / max. Maximum switching rate without load Ambient temperature Thermal resistance Maximum permissible coil temperature Vibration resistance (function) Shock resistance, half sinus, 11 ms half sinus, 0.5 ms Degree of protection Needle flame test Mounting position Processing information Weight (mass) Resistance to soldering heat 1 ms / 3 ms 1 ms /3 ms 1 ms / 3 ms 3 ms / 5 ms 1 ms / 5 ms 50 operations/s -40° C ... +85° C < 150 K/W 125° C 20 G 10 to 1000 Hz

50 G (function)

500 G (damage)

immersion cleanable, IP 67 application time 20 s, no burning and glowing any Ultrasonic cleaning is not recommended max. 0.75 g 260° C / 10 s IM Relay All data refers to 23° C unless otherwise specified. Recommended soldering conditions Soldering conditions according CECC 00802 Vapor Phase Soldering: Temperature/Time Profile (Lead Temperature) Infrared Soldering: Temperature/Time Profile (Lead Temperature) Full line: typical Dotted line: process limits 10 sec ca. 40 sec max. 245° C 215° C 130° C 180° C Time (s) 215° C 180° C 130° C 100° C external preheating 20 - 40 sec Full line: typical Dotted line: process limits forced cooling Time (s) Temperature °C Temperature °C

Tube for THT version - 50 relays per tube, 1000 relays per box Tape and reel for SMT version - 1’000 relays / reel, 1’000 or 5’000 relays / box Packing Dimensions in mm

Ordering Information

4th generation slim line – low profile polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with of 140... 200 mW, latching relays with 1 coil 100 mW. The IM relay is available as through hole and surface mount type (J-Legs and Gull Wings) and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills the Bellcore requirements according GR 1089 (2,5 kV – 2 / 10 µs) and FCC part 68 (1,5 kV – 10 / 160 µs). The IM is CECC/ IECQ approved and certified in accordance with IEC/EN 60950 and UL1950. Dimensions approx. 10 x 6 mm board space and 5.65 mm height. P2 Relays 3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption 140 mW, latching relays with 1 coil 70 mW. The P2 relay is available as through hole or surface mount type and capable to switch currents up to 5 A. Dielectric strength fulfills the Bellcore requirements according GR 1089 (2,5 kV – 2 / 10 µs) and FCC part 68 (1,5 kV – 10 / 160 µs). Dimensions approx. 15 x 7,5 mm board space and 10 mm height. FX Relays 3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage high sensitive version, 140... 300 mW for the standard version, latching relays with 1 coil 100 mW. The FX2 relay is available as through hole type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills the Bellcore requirements according GR 1089 (2,5 kV – 2 / 10 µs) and FCC part 68 (1,5 kV – 10 / 160 µs). The FX2 is CECC/IECQ approved and certified in accordance with IEC/EN 60950 and UL1950. Dimensions approx. 15 x 7,5 mm board space and 10,7 mm height. FT2 / FU2 Relays 3rd generation non polarized, non latching 2 c/o telecom relay with bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power through hole and surface mount type. Dielectric strength fulfills the Bellcore requirements according GR 1089 (2,5 kV – 2 / 10 µs) and FCC part 68 (1,5 kV – 10 / 160 µs). The FT2/FU2 is CECC/IECQ approved and certified in accordance with IEC/EN 60950 and UL1950. Dimensions approx. 15 x 7,5 mm board space and 10 mm height. FP2 Relays 3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal 260 mW for the high sensitive version, 140... 300 mW for the standard version, latching relays with 1 coil 100 mW.. The FP2 relay is available as through hole type and capable to switch loads up to 30 W/62,5 VA. Dielectric strength fulfills FCC part 68 (1,5 kV – 10 / 160 µs). The FP2 is CECC/IECQ approved. Dimensions approx. 14 x 9 mm board space and 5 mm height. MT2 / MT4 2nd generation non polarized, non latching 2 c/o and 4 c/o telecom and signal relay with bifurcated contacts. Nominal voltage range from 4.5 ... 48 V, coil power consumption 150/200/300/400 and 550 mW, and 300 mW (MT4). Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV – 10 / 160 µs) for both and the Bellcore requirements according GR 1089 (2,5 kV – 2 / 10 µs) the MT4 only. Dimensions MT2 approx. 20 x 10 mm board space and 11 mm height, MT4 approx. 20 x15 mm board space and 11 mm height. D2n Relays 2nd generation non polarized 2 c/o relay for telecom and various other applications. Nominal voltage range from 3 ... 48 V, coil power currents up to 3 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV – 10 / 160 µs). Dimensions approx. 20 x10 mm board space and 11,5 mm height. P1 Relays Extremely sensitive, polarized 1 c/o relay with bifurcated contacts for a wide range of applications, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption 65 mW, latching relays with 1 coil 30 mW. The P1 relay is available as through hole or surface mount type and capable to switch currents up to 1 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV – 10 / 160 µs). Dimensions approx. 13 x 7,6 mm board space and 7 mm height for THT or 8 mm height for SMT version. W11 Relays Low cost, non polarized 1 c/o relay for various applications. Nominal voltage range from 3 ... 24 V, coil power consumption 450 mW, sensitive versions 200 mW. The W11 relay is capable to switch currents up to 3 A. Dielectric strength 1000 Vrms. Dimensions approx. 15,6 x 10,6 mm board space and 11,5 mm height. Reed Relays High sensitive, non polarized relay for telecom and various other applications, available with 1 n/o, 2 n/o or 1c/o contacts. Nominal for 1 n/o and 125 ... 280 mW for 2 n/o or 1 c/o versions. Reedrelays are available in DIP or SIL housing and capable to switch currents up to 0,5 A. Integrated diode and/or electrostatic shield optional. Dielectric strength 1500 Vdc. Dimensions approx. 19,3 x 7 mm board space and 5 ... 7,5 mm height for DIP or 19,8 x 5 mm board space and 7,8 mm height for SIL version. Cradle Relays Extremely reliable and mature relay family of 1 st generation for various signal switching applications. Available as non polarized, polarized / latching and relay with AC coil. The benefit is the possibility of combining various contact sets from 1 up to 6 poles, single and bifurcated contacts, different contact materials with a coil voltage range from 1,5 Vdc to 220 Vac. Cradle relays are available as dust protected and hermetically sealed versions, with plug in or solder terminals and are capable to switch currents up to 5 A. Forcibly guided (linked) contact sets optional. Dielectric strength 500 Vrms. Dimensions from approx. 19 x 24 to 19x35 mm board space and 30 mm height. Other Relays We offer a variety of different relay families for maintenance and replacement purposes. These relays are up to 60 years old now, such as Card Relay SN (V23030 / V23031 series), Small General Purpose Relay (V23006 series), Small Polarized Relay (V23063 ... V23067 and V23163 ... V23167 series). Accessories like sockets, hold down springs, etc. optional. IM Relay

Tyco Electronics AXICOM Ltd. Seestrasse 295 - P.O. Box 220 CH-8804 Au-Wädenswil / Switzerland Phone +41 1 782 9111 Fax +41 1 782 9080 E-mail: axicom@tycoelectronics.com Tyco Electronics Corporation POB 3608, Harrisburg, PA 17105, USA Phone +1 800-522-6752 Tyco Electronics EC Trutnov s.r.o. Komenského 821 CZ-541 01 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.com Tyco Electronics AMP GmbH Paulsternstrasse 26 D-13629 Berlin / Germany Phone +49 30 386 38260 Fax +49 30 386 38569 E-mail: axicom@tycoelectronics.com April 2002 Rev. 3.01