ILI-MB-E3 GAMEWELL-FCI | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Features
ILI-MB-E3 and ILI-S-E3:
- Listed under UL Standard 864, 9th Edition
- Network ready integral 625K baud ARCNET
- 115.2K baud RS-232
- Signaling line circuits with: - Two (2), Class A, Style 6, 7* or Class B, Style 4 circuits - 40 Character user-defined text per device - Capacity of 159 sensors and 159 addressable modules per circuit
- 4100 event history log *Style 7 wiring requires the use of System Sensor M500X Isolator Modules. ILI-MB-E3 Only:
- Two (2), notification applianc e circuits, Class “A”, Style Z or Class B, Style Y rated at 2.0 amps. per circuit
- RS-485 supporting sixteen (16), ASM-16 switch mod- ules and/or ANU-48 LED driver modules
- Alarm, trouble, and supervisory dry contacts Form “C”, rated at 2 amp. @ 30 VDC (resistive)
- Supports six (6), local/remote LCD-E3 annunciators and five (5), LCD-7100 annunciators APPROVED FM MEA Approved SIGNALING City of Chicago Approved City of Denver ApprovedS1869 3025415 231-06-E 7165-0694:268 7165-0694:269 Class 1 Class 2 High Rise An ISO 9000-2000 Company
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
9000-0605 Rev. e1 page 2 of 2 www.gamewell-fci.com ILI-S-E3 ILI-S-E3 The Intelligent Loop Interface - Expansion Board (ILI-S-E3) provides the E3 Series control panel with two (2), additional signaling line circuits. The layout is similar to the ILI-MB-E3 except a number of components are omitted. The ILI-S-E3 occupies one node on the Broadband network. The ILI-S- E3 provides two (2), signaling line circuits and terminals for the connections to up to 159 detectors and 159 modules per SLC in Velociti mode. In clip mode, each SLC supports 99 detectors and 98 modules. Installation Typically, the ILI-MB-E3 or ILI-S-E3 can be mounted in the following E3 Series cabinets:
- Cabinet B and D, backbox
- Cabinet C, INX-E3 sub-assembly plate
- Cabinet C, INCC-E3 sub-assembly plate For instructions on installing the ILI-MB-E3 or ILI-S-E3, refer to the E3 Series ® Expandable Emergency Evacuation Installation/Operating Manual, Part Number: 9000-0574, the ILI-MB-E3 Installation Instructions, Part Number: 9000- 0579, or the ILI-S-E3 Installation Instructions, Part Number: 9000-0569. Specifications Operating Voltage: 24 VDC FWR (from PM-9 Power Supply) Operating Current: 0.081 amp. Alarm Current: 0.150 amp. max. Operating Temperature: 32° to 120° F (0° to 49° C) Relative Humidity: 0 to 93%, non-condensing at 90° F (32° C) SLC 40 Ohms maximum line impedance.- 0.5 µf maximum line capacitance.
Ordering Information
ILI-MB-E3 Intelligent Loop Interface-Main Board ILI-S-E3 Intelligent Loop Interface-Expansion Board