Rev. 1.9, 20-Apr-07 www.vishay.com For technical support, please contact: optocoupler.answers@vishay.com Optocoupler, Phototransistor Output, Dual Channel, SOIC-8 package, 110 °C Rated
FEATURES
- Operating temperature from - 55 °C to + 110 °C Two Channel Coupler SOIC-8 Surface Mountable Package Isolation Test Voltage, 4000 V RMS Compatible with Dual Wave, Vapor Phase and IR Reflow Soldering Lead (Pb)-free component Component in accordance to RoHS 2002/95/EC and WEEE 2002/96/EC i179018 8 C
DESCRIPTION
The 110 °C rated ILD1205T/1206T/1207T are optically coupled pairs with a Gallium Arsenide infrared LED and a silicon NPN phototrans istor. Signal information, including a DC level, can be transmitted by the device while maintaining a high degree of electrical isolation between input and output. The ILD1205T/1206T/ 1207T come in a standard SOIC-8 small outline package for surface mounting which makes it ideally suited for high density applications with limited space. In addition to eliminating through-holes requirements, this package conforms to standards for surface mounted devices. A specified minimum and maximum CTR allows a narrow tolerance in the electrical design of the adjacent circuits. The high BV CEO of 70 V gives a higher safety margin compared to the industry standard of 30 V. AGENCY APPROVALS UL - File No. E52744 System Code Y CUL - File No. E52744, equivalent to CSA bulletin 5A DIN EN 60747-5-2(VDE0884) Available with Option 1
APPLICATIONS
AC Adapters P L C s Switch Mode Power Supplies DC/DC Converters Microprocessor I/O Interfaces General impedance matching circuits Note: For additional information on the available options refer to Option Information. ORDER INFORMATION PART REMARKS ILD1205T CTR 40 - 80 %, SOIC-8 ILD1206T CTR 63 - 125 %, SOIC-8 ILD1207T CTR 100 - 200 %, SOIC-8
1) Tamb = 25 °C, unless otherwise specified. Rating for extended periods of the time can adversely affect reliability. Figure 1. Power Dissipation vs. Ambient Temperature
17544 P (m W)
1) Tamb = 25 °C, unless otherwise specified. evaluation. Typical values are for information only and are not part of the testing requirements. Figure 2. Switching Test Circuit
www.vishay.com Document Number 83599 Rev. 1.9, 20-Apr-07 Vishay Semiconductors ILD1205T/1206T/1207T For technical support, please contact: optocoupler.answers@vishay.com PACKAGE DIMENSIONS in inches (millimeters) 0.036 (0.91) 0.014 (0.36) 0.170 (4.32) 0.045 (1.14) 0.260 (6.6) R 0.010 (0.13) 0.050 (1.27) i178020 ISO Method A 40° 0.240 (6.10) 0.050 (1.27) Typ. 0.016 (0.41) 0.004 (0.10) 0.008 (0.20) Lead coplanarity ± 0.001 Max. 0.008(0.20) 0.120 ± 0.002 (3.05 ± 0.05) CL R0.010 (0.25) Max. 0.040 (1.02) 5° Max. Pin One I.D. 0.154 ± 0.002 (3.91 ± 0.05) 0.015 ± 0.002 (5.84 ± 0.05) 0.020 ± 0.004 (0.51 ± 0.10) 2 Plcs. 0.0585 ± 0.002 (1.49 ± 0.05) 0.125 ± 0.002 (3.18 ± 0.05)
Rev. 1.9, 20-Apr-07 www.vishay.com Vishay Semiconductors ILD1205T/1206T/1207T For technical support, please contact: optocoupler.answers@vishay.com OZONE DEPLETING SUBSTANCES POLICY STATEMENT It is the policy of Vishay Semiconductor GmbH to 1. Meet all present and future national and international statutory requirements. 2. Regularly and continuously improve the performance of our products, processes, distribution and operating systems with respect to their impact on the health and safety of our employees and the public, as well as their impact on the environment. It is particular concern to control or eliminate releases of those substances into the atmosphere which are known as ozone depleting substances (ODSs). The Montreal Protocol (1987) and its London Amendments (1990) intend to severely restrict the use of ODSs and forbid their use within the next ten years. Various national and international initiatives are pressing for an earlier ban on these substances. Vishay Semiconductor GmbH has been able to use its polic y of continuous improvements to eliminate the use of ODSs listed in the following documents. 1. Annex A, B and list of transitional substances of the Montreal Protocol and the London Amendments respectively 2. Class I and II ozone depleting substances in the Clean Air Act Amendments of 1990 by the Environmental Protection Agency (EPA) in the USA 3. Council Decision 88/540/EEC and 91/690/EEC Annex A, B and C (transitional substances) respectively. Vishay Semiconductor GmbH can certify that our semico nductors are not manufactured with ozone depleting substances and do not contain such substances. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All operating parameters must be validated for each customer application by the customer. Should the buyer use Vishay Semiconductors products for any unintended or unauthorized application, the buyer shall indemnify Vishay Semiconductors against all claims, costs, damages, and expenses, arising out of, directly or indirectly, any claim of personal damage, injury or death associated with such unintended or unauthorized use. Vishay Semiconductor GmbH, P.O.B. 3535, D-74025 Heilbronn, Germany
Document Number: 91000 www.vishay.com Revision: 08-Apr-05 1 Notice Specifications of the products displayed herein are subjec t to change without notice. Vishay Intertechnology, Inc., or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies. Information contained herein is intended to provide a product description only. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Vishay's terms and conditions of sale for such products, Vishay assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sale and/or use of Vishay products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications. Customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Vishay for any damages resulting from such improper use or sale.