IHVA150 TEC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
01-2021 Rev. 0121 www.te.com © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. General Purpose Contactors TE Connectivity High Voltage Contactors IHVA150 Series n Non-polarity for contact current n Maximum DC breaking capacity at 1500A n Maximum DC breaking capacity at 1500VDC n Maximum making inrush current capacity at 600A n Optional auxiliary contact available n High insulation resistance (14mm clearance/25mm creepage) Typical applications Charging station, AGV, Electric forklift, Energy storage systems, Photovoltaic inverter Approvals cULus E58304, CCC Main Contact Data Contact arrangement 1 Form X (SPST-NO-DM) Switching voltage range 1) 12 - 1500VDC Rated current 150 A Contact material Ag alloy Initial Voltage Drop 0.3mΩ (150A current 1 minute after) Operate Time max. 65ms Operate bounce time max. 2ms Release Time, max 20mS Mechanical Life 500,000 cycles Contact ratings Load Cycles 5A, 1500VDC, UL60947-4-1 200 20A, 1000VDC, UL60947-4-1 50 150A, 1500VDC, carry only, UL60947-4-1 / 150A, 110VDC, EN/UL60947-4-1 6,000 150A, 450VDC, 100 150A, 750VDC, 30 600A, make only, 3,000 1500A, 400VDC, break only 2 Auxiliary Contact Data Contact Form 1 Form A (SPST-NO) Contact Current, Max. 2A, 30VDC / 3A, 125VAC Contact Current, Min. 100mA, 8VDC Contact Resistance, Max. 0.3Ω @ 30VDC / 0.15Ω @ 125VAC Coil versions, DC coil Coil Nominal Operate Maximum Release Coil Coil Power code Voltage Voltage allowable Voltage resistance W VDC VDC voltage VDC Ω VDC 12 12 9 15 1 29 5 24 24 18 30 2 115 5 48 48 36 60 4 460 5 All figures are given for coil without pre-energization, at ambient temperature +23°C Insulation Data Dielectric Withstand Voltage (leakage current <1mA) between open contacts 5,600Vrms/8,000Vdc between contact and coil 6000Vrms Initial insulation resistance @ 500VDC between open contacts 1×108Ω between contact and coil 1×108Ω Clearance/creepage between contact and coil 14mm clearance/25mm creepage Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Ambient temperature DC coil -40°C to +85°C Category of environmental protection IEC 61810 RTII - flux proof Vibration resistance (functional) Sine, 55 – 2000Hz, Peak 20G Shock resistance (functional), 11ms 1/2 Sine, Peak 20G Terminal type Screw for contact, wire for coil Weight 465g Packaging/unit 20pcs/box IHVA150 Estimated Carrying Current Capability 2) 2) All figures are given at ambient temperature 85°C and the contactors connected with 2/0 cable 1) Please refer to “contact ratings” with the specified application condition. If there is no specified statement, the switching test was performed at room temp.
01-2021, Rev. 0121 www.te.com © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. General Purpose Contactors TE Connectivity High Voltage Contactors IHVA150 Series (Continued) Connection wire Dimensions Note: TE will provide 2 pairs of M8 nuts and gaskets. TE will provide the connection wire for coil terminals and auxiliary contact terminals (for the version with auxiliary contact).
01-2021 Rev. 0121 www.te.com © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. General Purpose Contactors TE Connectivity High Voltage Contactors IHVA150 Series (Continued) Product code Arrangement Mounting position Main Contact Material Coil Part number IHVA150-A3D12V-BF Normally Open Bottom Ag alloy 12VDC 2071547-1 IHVA150-A3D24V-BF 24VDC 2071547-2 IHVA150-A3D48V-BF 48VDC 2071547-3 IHVA150-H3D12V-BF Normally Open + NO Aux Contacts 12VDC 1-2071547-1 IHVA150-H3D24V-BF 24VDC 1-2071547-2 IHVA150-H3D48V-BF 48VDC 1-2071547-3 Product code structure IHVA 150 -A 3 D 12 V -B F ,XX Product series IHVA = IHVA Contactor Rated current 150 = 150A Contact form A = Normally Open H = Normally Open + NO Aux Contacts Main contact material 3 = Ag alloy Coil Power D = 5W Coil Voltage 12 = 12Vdc 24 = 24Vdc 48 = 48Vdc Enclosure V = RTII Mounting position B = Bottom Coil Terminal Connection F = Fasten Terminal Customer Special Designator XX 2 digit or letter specified by manufacture factory
01-2021, Rev. 0121 www.te.com © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. General Purpose Contactors TE Connectivity High Voltage Contactors IHVA150 Series (Continued) Precaution 1. When the Connection wire is inserted into the contactor, it is necessary to ensure that the convex hull of the Connection wire is stuck in the U-shaped groove to prevent the connecting wire from falling off. 2. Please do not directly connect the reverse diode to the coil if intend to suppress the reverse voltage of coil. It is recommended to use a reverse diode plus a Zener diode as below circuit. The regulated voltage is recommended to take 2 times the rated voltage of the coil. 3. When using PWM energy-saving control, ensure that the coil is firstly energized at rated coil voltage for 100mS, the PWM frequency is 20KHz, and duty cycle is > 25%.Similarly, do not directly connect the reverse diodes at both ends of the coil. 4. When the external circuit is connected to the contact end of the contactor, the copper bar used and the copper terminal plane around the bolt post must be in direct and close contact. Flat pad and elastic washer, the torque should be 8.8~11 N·M when tightening the nut to ensure reliable connection of the terminal and prevent the nut from loosening. 5. When the relay is switching the DC load circuit, the final mode of its switching life may cause the contact to be welded or the arc cannot be cut off. It is recommended that customers consider the precautions after relay failure to ensure safety in the actual application design.