60 Watt Single

/circle6 RoHS Compliant /circle6 18 - 40 & 33 - 75V Input Range /circle6 High Efficiency: 84% Typical /circle6 1500VDC Isolation Between Input and Output /circle6 Operation to 100oC Baseplate Temperature /circle6 50MS Transient Recovery, 0-90% Load Step /circle6 Primary & Secondary Remote On/Off /circle6 Adjustable Output V oltage /circle6 IHB60S Series Approved to UL/CUL 1950, EN60950 ISO9001 CERTIFIED INPUT VOLTAGE RATED V OUT (VDC) RATED MAXIMUM I OUT (A) MODEL (V DC) IHB60S2403C 24 (18-40) 3.3 18 IHB60S2405C 24 (18-40) 5.1 12 IHB60S4803C 48 (33-75) 3.3 18 IHB60S4805C 48 (33-75) 5.1 12 PRODUCT SELECTION CHART EFFICIENCY vs TEMPERATURE Case Temperature (°C) TCASE = +40°C, nominal input voltage, nominal load, recommended external components applied, unless otherwise specified. Change in Efficiency (%) Output Short-Circuit Duration Continuous Baseplate Temperature +100°C Storage Temperature +125°C Input to Output Isolation 1500 V DC ABSOLUTE MAXIMUM RATINGS The IHB60SC series standard half-brick modules are designed for today’s demanding industrial applications. Available in two wide range inputs, these isolated converters offer many features in the standard models. With a complement of safety agency approvals and low noise operations, the converters respond extremely fast to change in load conditions. Inherent in the design are very well-controlled output voltages and no need for minimum loading. OBSOLETE PRODUCT Contact factory for replacement model

2IHB60SC REV A (RoHS) 04/2006 SPECIFICATIONS, ALL MODELS Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. INPUT PARAMETER CONDITIONS MIN TYP MAX UNITS Voltage Range IHB60S24XC Series 18 24 40 V DC IHB60S48XC Series 33 48 75 V DC Reflected Ripple Current Peak - Peak 220 mA Input Ripple Rejection DC to 1KHz 50 60 dB Maximum Input Current Output Power = 60W IHB60S24XC Series V IN = 16V 6 A IHB60S48XC Series V IN = 30V 3 A No Load Power Dissipation P OUT = 0, VIN, Min<VIN<VIN, Max 6 W Inrush Charge IHB60S24XC Series 0.29 mC IHB60S48XC Series 0.165 mC Quiescent Operating Current Primary On/Off Disabled 7.5 10 mA Secondary On/Off Disabled 15 25 mA GENERAL PARAMETER CONDITIONS MIN TYP MAX UNITS ISOLATION Input to Output Peak Test 1500 V DC Input to Baseplate 1500 V DC Resistance, Input - Output 10 M 7 Capacitance, Input - Output 2000 pF Leakage Current V ISO = 240VAC, 60Hz 180 MA, rms GENERAL Set Point Accuracy VIN = Nominal, IO=INom 1 % Turn-on Time Within 1% of Nominal V OUT 3.5 5 mSec Remote On/Off Control Inputs Primary Open Collector/Drain Sink Current-Logic Low V IN = VMAX 7 mA Vlow 0.8 V Vhigh Open Collector Secondary Open Collector/Drain Sink Current-Logic Low 100 MA Vlow 0.4 V Vhigh Open Collector External Synchronization Input Frequency 440 520 KHz Pulse Width 150 320 nSec Source Impedence 47 7 Input High Voltage 4 5 V Input Low Voltage 0 1 V Input Impedance 470 7 Switching Frequency 470 480 490 KHz Weight 3 (85) oz (g) TEMPERATURE Case Temperature Operation/Specification -40 +100 oC Storage -55 +125 °C Shutdown +100 +115 °C Thermal Inpedance Case to Ambient 8.2 °C/W

3IHB60SC REV A (RoHS) 04/2006 SPECIFICATIONS, ALL MODELS Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. IHB60SX05C** OUTPUT V OUT PARAMETER CONDITIONS Min Nom Max UNITS Output Power 60 Watts Max 30 60 W Set Point Voltage I O Nom 5.1 V Output Current, IOUT 0 6.0 12 A Output Ripple, p-p DC to 20MHz* 100 200 mV Output Adjust Range * 4.60 5.50 V Output Temperature Drift .02 .05 %/°C Line Regulation V IN, Min≤VIN≤VIN, Max I O = IO, Nom 0.05 0.10 % Load Regulation Min Load to Rated Load 0.50 1.0 % Current Limit Inception 16.0 A Short-Circuit Current 12.6 16.0 A Transient Response 50 to 100% Load Step Peak Deviation 200 300 mV Settling Time V OUT, 1% of VOUT, Nom 35 50 MSec Overvoltage Limit 6.0 6.8 V Efficiency V IN=NOM, IO=12A 86 87 % *See Application Notes available on the web at www.murata-ps.com **X = Either 24 or 48 V OUT PARAMETER CONDITIONS Min Nom Max UNITS Output Power 60 Watts Max 30 60 W Set Point Voltage I O Nom 3.3 V Output Current, I OUT 0 9.0 18.0 A Output Ripple, p-p DC to 20MHz * 100 200 mV Output Adjust Range * 3.15 3.80 V Output Temperature Drift .02 .05 %/°C Line Regulation V IN, Min≤VIN≤VIN, Max I O = IO, Nom 0.05 0.10 % Load Regulation Min Load to Rated Load 0.50 1.00 % Current Limit Inception Other Outputs Min Load 23 A Short-Circuit Current 19 25 A Transient Response 50 to 100% Load Step Peak Deviation 150 250 mV Settling Time V OUT, 1% of VOUT, Nom 35 50 MSec Overvoltage Limit 4.2 5.0 V Efficiency V IN=NOM, IO=18A 83 84 % IHB60SX03C** OUTPUT These devices are intended for wave soldering or manual soldering. They are not intended to be subject to surface mount processes under any circumstances. The normal wave soldering process can be used with these devices where the device is subjected to a maximum wave temperature of 260°C for a period of no more than 10 seconds. Within this time and temperature range, the integrity of the device’s plastic body will not be compromised and internal temperatures within the converter will not exceed 175°C. Care should be taken to control manual soldering limits identical to that of wave soldering. THROUGH-HOLE SOLDERING INFORMATION

1 PRIMARY ON/OFF

4 SYNC IN

5 TRIM

8 SECONDARY ON/OFF

MATERIAL: Units are encapsulated in a low thermal resistance mold- ing compound which has excellent chemical resistance, wide operating temperature range, and good electrical properties under high humidity environments. The encapsulant and outer shell of the unit have UL94V-0 ratings. Lead material is matte tin 100 microinches min., over nickel, 40-80 microinches. NOTES: All dimensions are in inches (millimeters). PIN PLACEMENT TOLERANCE: ± 0.005" MECHANICAL TOLERANCE: ± 0.015" Marked with: specific model ordered, date code, job code. Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2009 Murata Power Solutions, Inc. USA: Mansfield (MA), Tel: (508) 339 3000, email: sales@murata-ps.com Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com UK: Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Germany: München, Tel: +49 (0)89-544334-0, email: ped.munich@murata-ps.com Japan: Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com China: Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com email: sales@murata-ps.com ISO 9001 & ISO 14001 REGISTERED