100 Watt Triple Output Half Brick DC/DC Converter
/circle633 - 75V Input Range /circle6Each Channel Independently Current Limited /circle6High Efficiency: 88% Typical /circle61500VDC Isolation Between Input and Output /circle6Operation to 100°C Baseplate Temperature /circle650µS Transient Recovery, 0-90% Load Step /circle6Primary & Secondary Remote On/Off /circle6IHB100T Series Approved to UL/CUL 1950, EN60950 The IHB100T series triple output standard half brick modules are designed for today’s demanding industrial applications. Available in two wide range inputs, these isolated converters offer many features in the standard models. With a complement of safety agency approvals and low noise operations, the converters respond extremely fast to change in load conditions. Inherent in the design are very well-controlled output voltage and minimal need for minimum loading on main (V1) output. EFFICIENCY vs TEMPERATURE Change in Efficiency (%) Case Temperature (°C) TCASE = +40°C, nominal input voltage, nominal load, recommended external components applied, unless otherwise specified.* INPUT VOLTAGE RATED V OUT (VDC ) RATED MAXIMUM I OUT (A) MODEL (V DC ) V1 (±) V2 (±) V3 (±) V1(±) V2(±) V3(±) IHB100T480312 48 (33-75) 3.3 12 12 30 4.2 4.2 IHB100T480315 48 (33-75) 3.3 15 15 30 3.4 3.4 IHB100T480512 48 (33-75) 5.1 12 12 20 4.2 4.2 IHB100T480515 48 (33-75) 5.0 15 15 20 2.0 2.0 PRODUCT SELECTION CHART Output Short-Circuit Duration Continuous Baseplate Temperature +100°C Lead Temperature (soldering, 10 seconds max) +300°C Storage Temperature +125°C Input to Output Isolation 1500 V DC ABSOLUTE MAX. RATINGS Corporate: www.cdtechno.com Product: www.cdpowerelectronics.com
2IHB100T REV A 10/01Product: www.cdpowerelectronics.com SPECIFICATIONS, ALL MODELS Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. INPUT PARAMETER CONDITIONS MIN TYP MAX UNITS Voltage Range 33 48 75 V DC Reflected Ripple Current Peak - Peak 370 mA Input Ripple Rejection DC to 1KHz 50 60 dB Maximum Input Current Output Power = 100W V IN = 30V 5 A No Load Power Dissipation P OUT = 0, VIN, Min<V IN<V IN, Max 6W Inrush Charge 0.247 mC Quiescent Operating Current Primary On/Off Disabled 7.5 10 mA Secondary On/Off Disabled 15 20 mA See Regulation CurvesSee Regulation Curves * See Application Notes available on the web at www.cdpowerelectronics.com IHB100T480312 OUTPUT PARAMETER CONDITIONS MIN TYP MAX UNITS ISOLATION Input to Each Output Peak Test 1500 V DC Input to Baseplate 1500 V DC Channel to Channel Any Channel to Any Channel 500 V DC Resistance, Input - Output 10 M Ω Capacitance, Input - Output 2000 pF Leakage Current V ISO = 240VAC , 60Hz 180 µA, rms GENERAL Set Point Accuracy V IN = Nominal, 50% Load 1 % Turn-on Time Within 1% of Nominal V OUT 3.5 5 mSec Remote On/Off Control Inputs Primary Open Collector/Drain Sink Current-Logic Low V IN = VMAX 7m A Vlow 0.8 V Vhigh Open Collector Secondary Open Collector/Drain Sink Current-Logic Low 100 µA Vlow 0.4 V Vhigh Open Collector External Synchronization Input Frequency 440 520 KHz Pulse Width 150 320 nSec Source Impedence 47 Ω Input High Voltage 4 5 V Input Low Voltage 0 1 V Input Impedance 470 Ω Switching Frequency 470 480 490 KHz Weight 3 (85) oz (g) TEMPERATURE Case Temperature Operation/Specification -40 +100 °C Storage -55 +125 °C Shutdown +100 +115 °C Thermal Inpedance Case to Ambient 8.2 °C/W GENERAL V1 V2 V3 UNITSPARAMETER CONDITIONS Min Nom Max Min Nom Max Min Nom Max Output Power Total Combined O/P Power =
100 Watts Max 50 100 25 50 25 50 W
Set Point Voltage I O Nom 3.3 12.2 12.2 V Output Ripple, p-p DC to 20MHz * 100 200 150 500 150 500 mV Output Adjust Range * 3.15 3.80 Dependent on V1 V Line Regulation V IN, Min≤VIN≤VIN, Max Load Regulation Min Load to Rated Load 0.50 1.00 % Current Limit Inception Other Outputs Min Load 38 6.0 6.0 A Short-Circuit Current 30 38 5.0 6.0 5.0 6.0 A Transient Response 50 to 100% Load Step Peak Deviation 150 250 mV Settling Time V OUT , 1% of VOUT , Nom 35 50 µSec Overvoltage Limit 4.2 5.0 V Efficiency I OUT1 =15A, (IOUT2 +IOUT3 )= 4.2A 85 86 % F.L. VIN=Nominal
3IHB100T REV A 10/01Product: www.cdpowerelectronics.com SPECIFICATIONS, ALL MODELS Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. See Regulation CurvesSee Regulation Curves IHB100T480315 OUTPUT See Regulation CurvesSee Regulation Curves IHB100T480515 OUTPUT * See Application Notes available on the web at www.cdpowerelectronics.com V1 V2 V3 UNITSPARAMETER CONDITIONS Min Nom Max Min Nom Max Min Nom Max Output Power Total Combined O/P Power =
100 Watts Maximum 50 100 25 50 25 50 W
Set Point Voltage I O Nom 3.3 15.85 15.85 V Output Ripple, p-p DC to 20MHz* 100 200 125 500 125 500 mV Output Adjust Range * 3.15 3.80 Dependent on V1 V Line Regulation V IN, Min≤VIN≤VIN, Max Load Regulation Min Load to Rated Load 0.50 1.0 % Current Limit Inception Other Outputs Min Load 38 5.0 5.0 A Short-Circuit Current 30 38 4.0 5.0 4.0 5.0 A Transient Response 50 to 100% Load Step Peak Deviation 150 250 mV Settling Time V OUT , 1% of VOUT, Nom 35 50 µSec Overvoltage Limit 4.2 5.0 V Efficiency I OUT1 =15A, (IOUT2 +IOUT3 ) = 3.4A 85 86 % F.L. VIN=Nominal See Regulation CurvesSee Regulation Curves V1 V2 V3 UNITSPARAMETER CONDITIONS Min Nom Max Min Nom Max Min Nom Max Output Power Total Combined O/P Power =
100 Watts Combined 50 100 25 50 25 50 W
Set Point Voltage I O Nom 5.1 12 12 V Output Ripple, p-p DC to 20MHz* 100 150 150 500 150 500 mV Output Adjust Range * 4.75 5.50 Dependent on V1 V Line Regulation V IN, Min≤VIN≤VIN, Max Load Regulation Min Load to Rated Load 0.50 1.0 % Current Limit Inception Other Outputs Min Load 26.0 6.0 6.0 A Transient Response 50 to 100% Load Step Peak Deviation 200 300 mV Settling Time V OUT , 1% of VOUT, Nom 35 50 µSec Overvoltage Limit 6.0 7.0 V Efficiency I OUT1 =10A, (IOUT2 +IOUT3 ) = 4.2A 86 87 % F.L. VIN=Nominal V1 V2 V3 UNITSPARAMETER CONDITIONS Min Nom Max Min Nom Max Min Nom Max Output Power Total Combined O/P Power = Set Point Voltage I O Nom 5.0 15.3 15.3 V Output Ripple, p-p DC to 20MHz* 100 150 125 500 125 500 mV Output Adjust Range * 4.60 5.50 Dependent on V1 V Line Regulation V IN, Min≤VIN≤VIN, Max Load Regulation Min Load to Rated Load 0.05 1.0 % Current Limit Inception Other Outputs Min Load 26.0 5.0 5.0 A Transient Response 50 to 100% Load Step Peak Deviation 200 300 mV Settling Time V OUT , 1% of VOUT, Nom 35 50 µSec Overvoltage Limit 6.0 7.0 V Efficiency I OUT1 =10A, (IOUT2 +IOUT3 ) = 4.2A 86 87 % F.L. VIN=Nominal IHB100T480512 OUTPUT
4IHB100T REV A 10/01Product: www.cdpowerelectronics.com Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Tel: 800.547.2537 Fax: 520.770.9369 C&D Technologies (Power Electronics) Ltd. Shannon, Co. Clare, Ireland C&D Technologies, (NCL) Milton Keynes MK14 5BU UK Tel: +44 (0)1908 615232 Fax: +44 (0)1908 617545 MECHANICAL Any data, prices, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to be accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user’s intended purpose and in user’s specific application. C&D Technologies, Inc. does not warrant or recommend that any of its products be used in any life support or aviation or aerospace applications. MATERIAL: Units are encapsulated in a low thermal resistance molding compound which has excellent chemical resistance and electrical properties in high humidity environments and over a wide operating temperature range. The encapsulant and outer shell of the unit have UL94V-0 ratings. Lead material is solder plated to allow ease of solderability. NOTES: All dimensions are in inches (millimeters). PIN PLACEMENT TOLERANCE: ± 0.005" MECHANICAL TOLERANCE: ± 0.015" Marked with: specific model ordered, date code, job code. PIN SIDE UP PIN SIDE DOWN SIDE VIEW