IHB100T480312C MURATA-PS | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
100 Watt Triple
/circle6 RoHS Compliant /circle6 33 - 75V Input Range /circle6 Each Channel Independently Current Limited /circle6 High Efficiency: 88% Typical /circle6 1500VDC Isolation Between Input and Output /circle6 Operation to 100oC Baseplate Temperature /circle6 50MS Transient Recovery, 0-90% Load Step /circle6 Primary & Secondary Remote On/Off /circle6 IHB100TC Series Approved to UL/CUL 1950, EN60950 The IHB100TC series triple output standard half brick modules are designed for today’s demanding industrial applications. Available in two wide range inputs, these isolated converters offer many features in the standard models. With a complement of safety agency approvals and low noise operations, the converters respond extremely fast to change in load conditions. Inherent in the design are very well-controlled output voltage and minimal need for minimum loading on main (V1) output. EFFICIENCY vs TEMPERATURE Change in Efficiency (%) Case Temperature (°C) TCASE = +40°C, nominal input voltage, nominal load, recommended external components applied, unless otherwise specified.* INPUT VOLTAGE RATED VOUT (VDC) RATED MAXIMUM IOUT (A) MODEL (V DC) V1 (±) V2 (±) V3 (±) V1(±) V2(±) V3(±) IHB100T480312C 48 (33-75) 3.3 12 12 30 4.2 4.2 IHB100T480315C 48 (33-75) 3.3 15 15 30 3.4 3.4 IHB100T480512C 48 (33-75) 5.1 12 12 20 4.2 4.2 IHB100T480515C 48 (33-75) 5.0 15 15 20 3.4 3.4 PRODUCT SELECTION CHART Output Short-Circuit Duration Continuous Baseplate Temperature +100°C Storage Temperature +125°C Input to Output Isolation 1500 V DC ABSOLUTE MAXIMUM RATINGS ISO9001 CERTIFIED OBSOLETE PRODUCT Contact factory for replacement model
2IHB100TC REV A (RoHS) 05/2006 SPECIFICATIONS, ALL MODELS Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. INPUT PARAMETER CONDITIONS MIN TYP MAX UNITS Voltage Range 33 48 75 V DC Reflected Ripple Current Peak - Peak 370 mA Input Ripple Rejection DC to 1KHz 50 60 dB Maximum Input Current Output Power = 100W V IN = 30V 5 A No Load Power Dissipation P OUT = 0, VIN, Min<VIN<VIN, Max 6 W Inrush Charge 0.247 mC Quiescent Operating Current Primary On/Off Disabled 7.5 10 mA Secondary On/Off Disabled 15 20 mA See Regulation CurvesSee Regulation Curves * See Application Notes available on the web at www.murata-ps.com IHB100T480312C OUTPUT PARAMETER CONDITIONS MIN TYP MAX UNITS ISOLATION Input to Each Output Peak Test 1500 V DC Input to Baseplate 1500 V DC Channel to Channel Any Channel to Any Channel 500 V DC Resistance, Input - Output 10 M 7 Capacitance, Input - Output 2000 pF Leakage Current V ISO = 240VAC, 60Hz 180 MA, rms GENERAL Set Point Accuracy VIN = Nominal, 50% Load 1 % Turn-on Time Within 1% of Nominal V OUT 3.5 5 mSec Remote On/Off Control Inputs Primary Open Collector/Drain Sink Current-Logic Low V IN = VMAX 7 mA Vlow 0.8 V Vhigh Open Collector Secondary Open Collector/Drain Sink Current-Logic Low 100 MA Vlow 0.4 V Vhigh Open Collector External Synchronization Input Frequency 440 520 KHz Pulse Width 150 320 nSec Source Impedence 47 7 Input High Voltage 4 5 V Input Low Voltage 0 1 V Input Impedance 470 7 Switching Frequency 470 480 490 KHz Weight 3 (85) oz (g) TEMPERATURE Case Temperature Operation/Specification -40 +100 oC Storage -55 +125 °C Shutdown +100 +115 °C Thermal Inpedance Case to Ambient 8.2 °C/W GENERAL V1 V2 V3 PARAMETER CONDITIONS Min Nom Max Min Nom Max Min Nom Max Output Power Total Combined O/P Power =
100 Watts Max 50 100 25 50 25 50 W
O Nom 3.3 12.2 12.2 V Output Ripple, p-p DC to 20MHz * 100 200 150 500 150 500 mV Output Adjust Range * 3.15 3.80 Dependent on V1 V Line Regulation V IN, Min≤VIN≤VIN, Max Load Regulation Min Load to Rated Load 0.50 1.00 % Current Limit Inception Other Outputs Min Load 38 6.0 6.0 A Short-Circuit Current 30 38 5.0 6.0 5.0 6.0 A Transient Response 50 to 100% Load Step Peak Deviation 150 250 mV Settling Time V OUT, 1% of VOUT, Nom 35 50 MSec Overvoltage Limit 4.2 5.0 V Efficiency I OUT1=15A, (IOUT2+IOUT3)= 4.2A 85 86 % F.L. V IN=Nominal
3IHB100TC REV A (RoHS) 05/2006 SPECIFICATIONS, ALL MODELS Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. See Regulation CurvesSee Regulation Curves See Regulation CurvesSee Regulation Curves * See Application Notes available on the web at www.murata-ps.com V1 V2 V3 U PARAMETER CONDITIONS Min Nom Max Min Nom Max Min Nom Max Output Power Total Combined O/P Power =
100 Watts Maximum 50 100 25 50 25 50 W
O Nom 3.3 15.85 15.85 V Output Ripple, p-p DC to 20MHz* 100 200 125 500 125 500 mV Output Adjust Range * 3.15 3.80 Dependent on V1 V Line Regulation V IN, Min≤VIN≤VIN, Max Load Regulation Min Load to Rated Load 0.50 1.0 % Current Limit Inception Other Outputs Min Load 38 5.0 5.0 A Short-Circuit Current 30 38 4.0 5.0 4.0 5.0 A Transient Response 50 to 100% Load Step Peak Deviation 150 250 mV Settling Time V OUT, 1% of VOUT, Nom 35 50 MSec Overvoltage Limit 4.2 5.0 V Efficiency I OUT1=15A, (IOUT2+IOUT3) = 3.4A 85 86 % F.L. V IN=Nominal See Regulation CurvesSee Regulation Curves V1 V2 V3 U PARAMETER CONDITIONS Min Nom Max Min Nom Max Min Nom Max Output Power Total Combined O/P Power =
100 Watts Combined 50 100 25 50 25 50 W
O Nom 5.1 12 12 V Output Ripple, p-p DC to 20MHz* 100 150 150 500 150 500 mV Output Adjust Range * 4.75 5.50 Dependent on V1 V Line Regulation V IN, Min≤VIN≤VIN, Max Load Regulation Min Load to Rated Load 0.50 1.0 % Current Limit Inception Other Outputs Min Load 26.0 6.0 6.0 A Transient Response 50 to 100% Load Step Peak Deviation 200 300 mV Settling Time V OUT, 1% of VOUT, Nom 35 50 MSec Overvoltage Limit 6.0 7.0 V Efficiency I OUT1=10A, (IOUT2+IOUT3) = 4.2A 86 87 % F.L. V IN=Nominal V1 V2 V3 U PARAMETER CONDITIONS Min Nom Max Min Nom Max Min Nom Max Output Power Total Combined O/P Power = O Nom 5.0 15.3 15.3 V Output Ripple, p-p DC to 20MHz* 100 150 125 500 125 500 mV Output Adjust Range * 4.60 5.50 Dependent on V1 V Line Regulation V IN, Min≤VIN≤VIN, Max Load Regulation Min Load to Rated Load 0.05 1.0 % Current Limit Inception Other Outputs Min Load 26.0 5.0 5.0 A Transient Response 50 to 100% Load Step Peak Deviation 200 300 mV Settling Time V OUT, 1% of VOUT, Nom 35 50 MSec Overvoltage Limit 6.0 7.0 V Efficiency I OUT1=10A, (IOUT2+IOUT3) = 4.2A 86 87 % F.L. V IN=Nominal IHB100T480512C OUTPUTIHB100T480515C OUTPUT IHB100T480315C OUTPUT
4IHB100TC REV A (RoHS) 05/2006 MECHANICAL MATERIAL: Units are encapsulated in a low thermal resistance molding compound which has excellent chemical resistance and electrical properties in high humidity environments and over a wide operating temperature range. The encapsulant and outer shell of the unit have UL94V-0 ratings. Lead material is solder plated to allow ease of solderability. NOTES: All dimensions are in inches (millimeters). PIN PLACEMENT TOLERANCE: ± 0.005" MECHANICAL TOLERANCE: ± 0.015" Marked with: specific model ordered, date code, job code. PIN SIDE UP PIN SIDE DOWN SIDE VIEW
1 PRIMARY ON/OFF
4 SYNC IN
7 TRIM
10 SECONDARY ON/OFF
These devices are intended for wave soldering or manual soldering. They are not intended to be subject to surface mount processes under any circumstances. The normal wave soldering process can be used with these devices where the device is subjected to a maximum wave temperature of 260°C for a period of no more than 10 seconds. Within this time and tem- perature range, the integrity of the device’s plastic body will not be compromised and internal temperatures within the converter will not exceed 175°C. Care should be taken to control manual soldering limits identical to that of wave soldering. THROUGH-HOLE SOLDERING INFORMATION Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2009 Murata Power Solutions, Inc. USA: Mansfield (MA), Tel: (508) 339 3000, email: sales@murata-ps.com Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com UK: Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Germany: München, Tel: +49 (0)89-544334-0, email: ped.munich@murata-ps.com Japan: Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com China: Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com email: sales@murata-ps.com ISO 9001 & ISO 14001 REGISTERED