Absolute maximun ratings T AMBIENT = T AIR COOLING = 40°C unless otherwise specified Symbol Conditions Unit IOUT MAX Maximum continuous output current ARMS VOUT MAX Maximum output voltage VAC VBUS MAX Maximum DC Bus voltage in operation VDC FOUT Inverter Output frequency Hz FSW Maximum switching frequency kHz Electrical characteristics T AMBIENT = T AIR COOLING = 40°C unless otherwise specified Symbol Conditions min typ max Unit IOUT RATED Rated output current 200 ARMS VOUT Output voltage 400 VAC POUT Rated output power 140 kW FSW Inverter switching frequency 3 kHz FOUT Output frequency 50 Hz SEMIKUBE - Size T0.5 3-phase inverter VBUS Rated DC voltage 750 VDC PLOSS INV 1 915 W η >98 % Ordering No. 08800445 Filtering characteristics Description IGD-1-424-P1N4-DL-FA VBUS Rated DC voltage applied to the caps bank without switching 1 100 VDC Option 0C 0N 0P K - 0X - 1F2 Features τd5% Discharge time of the capacitors (5%) 285 s CDC Capacitor bank capacity 1,43 1,68 mF Designed in regards to EN50178 recommandations LTE Calculated LTE of the caps with forced air cooli ng > 100 kH RoHS compliant Stack Insulation Fast mounting and dismounting Very high life-time expectancy Integrated voltage, current and temperature sensors Air cooled power stacks Typical Applications Industrial applications Solar Inverters Footnotes 1) the user shall ensure that the ambiant air shall be ventilated in order not to create temperature hot spots. REMARKS © by SEMIKRON 1 A COMPLETER 3 200 VBUS=750VDC, No overload, Tj<150°C, Power factor PF = 1, Cabinet airflow in operation at 400m3/h Fan airflow through heatsink at 900 m3/h 500 VDC CAPACITOR Max DC voltage applied to the caps bank (max 30% of LTE) without switching Inverter efficiency 1 100 VDC IGBT Module stack Total power losses B6CI This technical information specifies semiconductor devices but promises no characteristics. No warranty or guarantee, expressed or implied is made regarding delivery, performance or suitability. VFrame / Power stage AC/DC (insulation test voltage DC, 60s)VISOL Rev. 3 - 31.08.2012 Values 200 900 AC phase Efficiency 500 DC Bus
Characteristics Conditions min typ max Unit Ambient temperature Humidity Installation altitude without derating 1 000 m IEC 60529 IP00 - EN 50178 2 - Thermal data V SUPPLY Heatsink fan AC voltage supply 230 VAC PFAN at 50Hz Rated power at VSUPPLY 300 W SEMIKUBE - Size T0.5 3-phase inverter Gate Driver Characteristcs T AMBIENT =25°C unless otherwise specified Symbol Conditions min typ max Unit Ordering No. 08800445 Gate Driver / controler data Description IGD-1-424-P1N4-DL-FA VS supply voltage 21,6 24 26,4 VDC Option 0C 0N 0P K - 0X - 1F2 ISO Supply primary current No load 360 mA Max. Supply primary current 1 500 mA Features ViT+ input threshold voltage HIGH 0.7 x VS VDC ViT- input threshold voltage LOW 0.3 x VS VDC Designed in regards to EN50178 recommandations RIN Input resistance 17 kΩ RoHS compliant CIN Input capacitance 1 nF Fast mounting and dismounting Measurement & protection Very high life-time expectancy Scaling 10 mV.V-1 Integrated voltage, current and temperature sensors Accuracy of analogue signal @ Ta=25°C -2 +2 % Air cooled power stacks Temperature coefficient 0,03 %.K-1 max. load current 5 mA Typical Applications Max. voltage range 15 VDC Max measurable DC Link Voltage 1 200 VDC Industrial applications Scaling 24 mV.A-1 Solar Inverters Accuracy of analogue signal -4 +4 % Temperature coefficient 0,07 %.K-1 Max. output current 5 mA Max. voltage range 15 VDC Footnotes ITRIPSC Over current trip level 450 APEAK Scaling 10 mV.°C-1 1) the user shall ensure that the ambiant air shall be Minimum measurable temperature 25 °C ventilated in order not to create temperature hot spots. Max. output current 5 mA Max. voltage range 15 VDC Ttp Over temperature protection 95 100 105 °C REMARKS Tth Threshold level for reset after failure event 70 °C © by SEMIKRON 2 IGBT Module stack B6CI Protection index Pollution degree Weight total DC link voltage sensing U DC analogue OUT Current sensing I analogue OUT per phase This technical information specifies semiconductor devices but promises no characteristics. No warranty or guarantee, expressed or implied is made regarding delivery, performance or suitability. Climatic Mechanical IEC 60721-3-3, class 3K3 extended In operation -25 55 °C IEC 60721-3-3, class 3K3 no condensation no icing 5 85 % Rev. 3 - 31.08.2012 kg25 Temperature sensing Tanalogue OUT 3-phase inverter including heatsink fan
Manufacturer: HARTING Part number: 09 18 534 7 813 © by SEMIKRON 3 Terminal fan power supply connection Rev. 3 - 31.08.2012
Driver X1 connector assignment © by SEMIKRON 4 [dominant/recessive]
28 BOT phase W Switching Signal IN
24VDC digital logic input, push pull LOW = "Switch off" HIGH = "Switch on"
15 TOP phase U Switching Signal IN
24VDC digital logic input, push pull LOW = "Switch off" HIGH = "Switch on"
16 BOT Phase U Switching Signal IN
24VDC digital logic input, push pull LOW = "Switch off" HIGH = "Switch on" 33,34
26 GND (I Analogue phase V)
[Reserved] 29 [Reserved] I phase W Analogue OUT Ground for I phase V Analogue OUT
27 TOP phase W Switching Signal IN
24VDC digital logic input, push pull LOW = "Switch off" HIGH = "Switch on"
24 GND (TOP phase V, BOT phase V) Ground for TOP & BO T phase V IN
25 I phase V Analogue OUT Nominal voltage range: 0…10 V
23 [Reserved] [dominant/recessive]
21 TOP phase V Switching Signal IN
24VDC digital logic input, push pull LOW = "Switch off" HIGH = "Switch on"
11 Temperature Analogue OUT Nominal voltage range: 0… 10V
12 GND (Temperature Analogue) Ground for Temperature Analogue OUT
DC Analogue OUT Nominal voltage range: 0…10V
14 GND (U DC Analogue) Ground for UDC Analogue OUT
18 GND (TOP phase U, BOT phase U) Ground for TOP & BO T phase U IN
17 [Reserved] [dominant/recessive] GND (Signal Status)8 10 [Reserved] [dominant/recessive]
9 Signal Status BIDIRECTIONAL
24VDC digital logic input, push pull LOW [dominant] = "Not ready to operate" HIGH [recessive] = "Ready to operate" Nominal voltage range: 0…10V GND (I Analogue phase W) Ground for I phase W Analog ue OUT 7 [Reserved] [dominant/recessive]
22 BOT Phase V Switching Signal IN
24VDC digital logic input, push pull LOW = "Switch off" HIGH = "Switch on" Ground for Signal Status OUT 2,4,6 GND PIN Signal Specification V S IN1,3,5 Supply voltage Rev. 3 - 31.08.2012
19 I phase U Analogue OUT Nominal voltage range: 0…10 V
20 GND (I Analogue phase U) Ground for I phase U Anal ogue OUT
GND (TOP phase W, BOT phase W) Ground for TOP & BOT phase W IN
This technical information specifies semiconductor devices but promises no characteristics. No warranty or guarantee expressed or implied is made regarding delivery, performance or suitability. © by SEMIKRON 5Rev. 3 - 31.08.2012
© by SEMIKRON 6 Max. Output current vs. Switching frequency Safe Ope rating Area Rev. 3 - 31.08.2012 Max. Output current vs. Ambient temperature Max. Out put current vs. DC bus voltage Thermal characteristics 100 150 200 250 0 200 400 600 800 1000 [ARMS ] [VDC ] SOA VBUS IOUT (*) Transient current 0,005 0,01 0,015 0,02 0,025 1 10 100 1000 Zth heatsink to ambient Time heatsink Poly. (heatsink) [ KW -1] [s] 100 150 200 250 0 5 10 15 20 25 [ARMS ] [kHz] 30°C 40°C 50°C fsw IOUT Cooling air temperature 100 150 200 25 30 35 40 45 50 55 60 65 [ARMS ] This curve does not consider the SEMIKUBE ambient temperature Fsw = 3kHz Fsw = 5kHz Fsw = 7kHz Fsw = 9kHz Fsw = 12kHz Switching frequency IOUT Tair cooling [ C] 100 150 200 250 300 400 500 600 700 800 900 [VDC ] 40°C 50°C 55°C VBUS IOUT [ARMS ] Cooling air temperature Switching frequency at 7 kHz