Set your site on VICOR at www.vicorpower.com Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 International Front End Rev. 1.1 Page 1 of 7 PRELIMINARY Parameter Rating Unit Notes L to N voltage 264 Vrms Continuous +Out to –Out voltage 400 Vdc B OK to –Out voltage 16 Vdc EN to –Out voltage 16 Vdc Mounting torque 15 (1.7) in-lbs (N-m) 6 M4 x 0.7 Operating temperature 95 °C Chassis/BP Storage temperature 125 °C Ambient Absolute Maximum Ratings Part Numbering IFE International AC Front End

500 WattsFeatures

  • Autoranging 115/230 Vac input
  • Two, low profile, chassis mount versions
  • 500 Watts
  • Me etsEN55022-B
  • Meets EN61000-3-2 harmonic current limits
  • Rugged coldplate construction Product Overview The International Front End (IFE) is an enclosed chassis mount, AC Front End which may be used with VIPAC Arrays, MegaModules or any of Vicor's 300V input DC-DC converters to create a complete, low profile, high density, AC-DC power supply. The IFE operates from worldwide AC mains and includes autoranging line rectification, integral EMI filtering, hold-up capacitors, harmonic current attenuation and transient suppression. The IFE incorporates Vicor's passive harmonic current attenuation technology and FARM modules to deliver 500 Watts while meeting EN61000-3-2 limits. All internal heat producing components are coupled to the chassis for optimal thermal transfer. Two rugged, coldplate packages are available — one with threaded inserts and the other with thru hole flanges — which may be mounted directly to a cabinet wall or an existing heat sink for high temperature operation. The International Front Ends (IFE) provide an off-the-shelf solution for many custom and standard power supply requirements where space constraints and time to market are critical. IFE 5 C 0 2 Product Type 5 = 500 W Termination 0 = Connector Product Grade C = -20°C to 95°C (BP) T = -40°C to 95°C (BP) Base Style 1 = External flange 2 = Internal threaded Options

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 International Front End Rev. 1.1 Page 2 of 7 Set your site on VICOR at www.vicorpower.com PRELIMINARY Parameter Min Typ Max Unit Notes Output voltage 250 375 Vdc Output power 500 550 Watts 90-132 / 180-264 Vac input Hold-up time

90 Vac Input 23 ms 500 W output

115 Vac Input 58 ms 500 W output

90 Vac Input 93 ms 500 W output with 2460 µF external

115 Vac Input 229 ms 500 W output with 2460 µF external

Pow er fail warning time 6.5 ms 115 Vac input, 500 W output Pow er fail warning time 25 ms 115 Vac input, 500 W output with 2460 µF external hold-up capacitor Parameter Min Typ Max Unit Notes Operating input voltage 90 115 132 Vac Autoranging (doubler mode) Operating input voltage 180 230 264 Vac Autoranging (bridge mode) AC line frequency 47 63 Hz Pow er factor 0.68 0.72 230 Vac input Efficiency 94 96 % Full load Input current 115 Vac input 9 9.5 Arms 500 W output 230 Vac input 4.5 4.75 Arms 500 W output Inrush current

115 Vac input 15 A pk

230 Vac input 30 A pk

ELECTRICAL CHARACTERISTICS

Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. Parameter Min Typ Max Unit Notes Safety approvals (pending) cTÜVus, CE Marked CE marked according to the Low Voltage Directive 72/23/EEC amendment 93/68/EEC Isolation voltage (in to out) none Isolation voltage (I/O to chassis) 2121 Vdc Leakage current TBD 264 Vac input, 50Hz SAFETY SPECIFICATIONS

Set your site on VICOR at www.vicorpower.com Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 International Front End Rev. 1.1 Page 3 of 7 PRELIMINARY Parameter Min Typ Max Unit Notes Harmonic currents EN61000-3-2 See Fig. 1 Voltage fluctuations and flicker EN61000-3-3 Test in process Input surge withstand EN61000-4-5 Test in process RF line conducted immunity EN61000-4-6 Test in process Voltage dips and interrupts EN61000-4-11 Test in process Conducted emissions EN55022, Level B See Fig. 2 ELECTROMAGNETIC COMPATIBILITY Parameter Min Typ Max Unit Notes Enable Low state current 50 mA Bus normal Low state resistance 15 ohms To negative output High state voltage 15 Vdc 150k internal pull up to 16 Vdc Enable threshold 235 240 Vdc Output bus voltage Disable threshold 185 Vdc Output bus voltage Bus OK Low state current 50 mA Bus normal Low state resistance 15 ohms To negative output High state voltage 15 Vdc 150k internal pull up to 16 Vdc B OK true threshold 235 240 245 Vdc Output bus voltage B OK false threshold 200 205 210 Vdc Output bus voltage CONTROL SPECIFICATIONS Parameter Min Typ Max Unit Notes MTBF Coldplate and Cover material aluminum W eight 1.13 (2.5) kg (lbs.) Package size L x W x H Internal threaded (IFE5xx2) 240 x 100 x 26.25 (9.45" x 3.93" x 1.12")mm (in) Thru hole flange (IFE5xx1) 260 x 100 x 26.25 (10.24" x 3.93" x 1.12")mm (in) Mounting Internal Threaded M4 x 0.7 6 locations max. 12mm max penetration, torque 15 in. lbs. (1.7Nm) Flange clearance hole M4 or #8 4 locations Storage Temperature C, T-Grade -40 125 °C Operating Temperature C-Grade -20 95 °C T-Grade -40 95 °C GENERAL SPECIFICATIONS ELECTRICAL CHARACTERISTICS, continued

Set your site on VICOR at www.vicorpower.com Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 International Front End Rev. 1.1 Page 5 of 7 PRELIMINARY Connection Diagram +In PC (Gate In) PR (Gate Out) –In +In PC (Gate In) PR (Gate Out) –In Vicor 300Vin DC-DC Converter Vicor 300Vin DC-DC Converter 1 ST 2 SR 3 –V OUT 4 –V OUT

5 B OK

Pin# Function IFE Output Connector 4 8 3 7 2 6 1 5 IFE LI L2/N PE Optional External Hold-Up Capacitor Mating Connector Function Description Vicor P/N Mfg. P/N IFE Input fuse 5 x 20 mm, 10A fast acting Wickman Series 194 IFE Input Connector 0.25'' male Faston 0.25'' insulated receptacle IFE Output Connector 8 position AMP Duac Housing 25056 AMP P/N 794657-8 Pins 24796 AMP P/N1-106529-2 Kit (Pins & Housing) 25073 VIPAC Array Input Connector J1 20 position AMP Duac Housing 24795 AMP P/N 2-794657-0 Pins 24796 AMP P/N 1-106529-0 Kit (Pins & Housing) 24828 VIPAC Array Input Connector J2 Housing 27866 Molex 39-01-2025 Pins 27867 Molex 39-00-0039 Kit (Pins & Housing) 27881 1 ST 2 SR 3 –V OUT 4 –V OUT Pin# Function IFE LI L2/N PE 4 8 3 7 2 6 1 5 IFE Output Connector 1-4 –V IN 5-7 +V IN

8 NC/PR Bus

18 NC/PR Bus

Pin# Function J1 Input Connector 10 20 9 19 8 18 7 17 6 16 5 15 4 14 3 13 2 12 1 11 VIPAC Array Optional External Hold-Up Capacitor +5V 11-13 –VIN 14-17 +VIN – Remote Enable + Remote Enable Pin# Function Enable SR J2 Input Connector Figure 3—Connection diagram using IFE with Vicor 300 Vin DC-DC converter(s) Figure 4—Connection diagram using IFE with ViP AC Array

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 International Front End Rev. 1.1 Page 6 of 7 Set your site on VICOR at www.vicorpower.com PRELIMINARY MECHANICAL DRAWINGS 100±0.76 3.937±0.030 260 ±0.76 10.236 ±0.030 INPUT 28.25 ±0.76 1.112 ±0.030 OUTPUT 5 ±0.38 0.197 ±0.015 2 PL 3.543 2 PL 5 ±0.38 0.197 ±0.015 2 PL 250 9.843 2 PL 0.213 THRU 4 PL5.41 ø OUTLINE DRAWING IFE5xx1 3.386 3 PL 7 ±0.38 0.276 ±0.015 3 PL 211 8.307 2 PL 139 5.472 2 PL 14.5 ±0.38 0.571 ±0.015 2 PL M4 X 0.7 MOUNTING

6 PL MARKED 'B'

'B' 'B' 'B' 'B' 'B' 'B' 28.25 ±0.76 1.112 ±0.030 OUTPUTINPUT 100 ±0.76 3.937 ±0.030 240 ±0.76 9.449 ±0.030 OUTLINE DRAWING IFE5xx2

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715International Front End P/N 27902 Rev.1.1 04/04/10M Set your site on VICOR at www.vicorpower.com Vicor Corporation

25 Frontage Road

Andover, MA, USA 01810 Tel: 800-735-6200 Fax: 978-475-6715 Email V icor Express: vicorexp@vicr.com Technical Support: apps@vicr.com Component Solutions for Your Power System45 V icor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to V icor’s Terms and Conditions of Sale, which are available upon request. Specifications are subject to change without notice.