Business-Critical Continuity Quarter-Brick Series Fixed Ratio 2nd Generation IBC Special Features
- 48 V input with isolated 9.6 V output
- Ultra-high efficiency, 97%
- Unprecedented usable output power levels
- High power density open-frame technology
- Wide operating ambient temperature range
- DOSA quarter-brick high current footprint and pinout
- Low profile, 0.48” (12.2 mm)
- Meets basic insulation requirements of EN60950-1
- Remote ON/OFF and overtemperature protection
- RoHS compliant
- 2 Year Warranty Total Power: 600W Input Voltage: 38 - 55VDC Rev. 02.11.09_162 Quarter-Brick Fixed IBC60 1 of 4 Safety UL/cUL : CAN/CSA 22.2 No. 60950-1 : UL60950-1 File No. E135734 VDE File No. 10401-3336-0206 Licence No. 40012752 Electrical Specifications Input Input voltage range: 38-55 Vdc Input current: Remote OFF 6.5 mA typ. Input current (max.): (See Note 1) 13 A max. @ lo max. and Vin = min. rated Input reflected ripple: (See Note 4) 1200 mA (pk-pk) 35 mA rms Remote ON/OFF Logic compatibility ON OFF: (See Note 6) Open collector ref. to -Input > 2.4 Vdc < 0.4 Vdc Undervoltage lockout: Power up Power down 34.5 V 33 V Start-up time: (See Note 3) Power up Remote ON/OFF 11rms 2 rms Output Line regulation: Low line to high line See table Load regulation: Full load to min. load See Table Total error band: (including setpoint, line, load and temperature) Vin = 38 V to 55 V 7.0 - 11.0 Vdc Minimum load: 0 A Overshoot: At turn-on and turn-off None Undershoot: None Ripple and Noise: 5-20 MHz (See Note 2) 100 mV pk-pk typ. 20 mV rms typ. All specifications are typical at nominal input, full load at 25 °C ambient unless otherwise stated
Rev. 02.11.09_162 Quarter-Brick Fixed IBC60 2 of 4 Embedded Power for Business-Critical Continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 EMC Characteristics Immunity: ESD air enclosure: EN61000-4-2 8 kV, 6 kV Air, contact Input transients: Input voltage Duration before shutdown > 59 V 2 Seconds > 60 V 1 Second > 62 V 0 Seconds General Specifications Efficiency: 97% Basic insulation: Input/output 2250 Vdc Switching frequency: Fixed 340 kHz typ. Approvals and (Pending) standards: (See Note 5) EN60950-1 VDE UL/cUL60950-1 Material flammability: UL94V-0 Weight: 59 g (2.08 oz) MTBF representative model: Telcordia Tech SR-332
48 Vin, 40 ˚C, 50% load
Protection: Short-circuit Hiccup Overvoltage: (See Note 9) Non-latching Thermal 140 ˚C hot spot Environmental Specifications Thermal Performance: Operating ambient temperature Non-operating -40 ˚C - +85 ˚C -55 ˚C to +125 ˚C Electrical Specifications Continued
Rev. 02.11.09_162 Quarter-Brick Fixed IBC60 of 4 Embedded Power for Business-Critical Continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 I B C 6 0 A Q N 4 8 9 6 - R E N J Part Number System with Options Rated Output Current
60 A = 60 Amps at 48 V
Blank = Positive R = Negative (See Note 6) Input Voltage Type T = Narrow Input Fixed Ratio S = Narrow Input Semi-reguated N = Narrow Telecom Fixed Ratio W = Wide Telecom Semi-reguated RoHS Compliance J = Pb-free (RoHS 6/6 compliant) Product Family IBC = Intermediate Bus Converter 2nd Generation Output Voltage 96 = 9.6 V Input Voltage 48 = 48 V Form Factor Q = Quarter-Brick Package, Body Height E = Open-Frame, 0.48 in (12.2 mm) Pin Length Options Blank = 0.188 ” (4.78 mm) Notes 1 Recommended input fusing is a 20 A HRC 250 V rated fuse. 2 Measured with external filter. See Application Note 209 for details. 3 Start-up into resistive load. 4 Peak to peak measured without external Pi filter. Significant reduction possible with external filter. See Application Note 209 for details.
5 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product. 6 Active-low remote ON/OFF option is also available. Please add the suffix ‘-R’ to the part number, e.g. IBC60AQN4896-REJ. 7 Maximum output power at maximum input voltage. 8 Efficiency at 100% maximum output voltage.
9 After an input overvoltage latch off, the input voltage must be returned to 55
V or lower for unit to restart. CAUTION: Hazardous internal voltages and high temperatures. Ensure that unit is not user accessible.
Ordering Information
(Max.) Input Voltage Output Voltage Output Current (min.) Output Current max.) Efficiency (typ) Regulation Model NumbersSet Point Accuracy Line % Load % 642 W 38-55 Vdc 9.6 V 0 A 60 A 97% -- 32.5% 2.5% IBC60AQN4896J
Business-Critical Continuity Rev. 02.11.09_162 Quarter-Brick Fixed IBC60 4 of 4 Dimensions in Inches (mm) Tolerances (unless otherwise specified) x.xx 0.02 (x.x 0.5) x.xxx 0.010 (x.xx 0.25) øx.xxx 0.003 (øx.xx 0.08) 2.000 (50.80) 2.300 (58.42) 0.300 (7.62) 0.725 (18.42) 0.140 (3.56) ø0.080 (2.03) ø0.040 (1.02) ø0.100 (2.54) ø0.062 (1.57) 0.145 (3.68) 0.04 (1.0) MIN ø0.090 (2.35) MAX 0.49 (12.45) ø0.118 (3.00) Hotspot location for thermal derating. 2.300 (58.42) 0.145 (3.68) ø0.080 (2.03) (3 pls) RECOMMENDED HOLE PATTERN ø0.100 (2.54) (4 pls) 0.450 (11.43) 0.450 (11.43) 0.300 (7.62) 2.000 (50.80) 01.45 (36.8) 0.300 (7.62) 0.725 (18.42) Americas
5810 Van Allen Way
Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.powerconversion.com techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co. EmersonNetworkPower.com Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Pin Connections Pin Number Function 1 + Vin