IAX SENSATA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

Features

Percentage of Rated Current vs Trip Time in Seconds Typical Resistance / Impedance Inrush Pulse Tolerance Our lowest depth breaker family, the Airpax IAX/LUX/LEX series hydraulic magnetic circuit breaker allows increased density in datacenter rack power distribution units while leaving more space for equipment, wiring and airflow. These UL-489 Listed and IEC 60947-2 (pending) breakers are available in 1 and 2 pole models using a unique handle actuator (patent pending) which minimizes breaker volume while maintaining reliable switching and over current protection. Available high interrupt capacity 10 kAIC and low resistance all copper conductors meet the needs of high performing, high efficiency datacenters. SPECIFICATIONS

  • Based on the proven high performance of the Airpax LEG series
  • Low depth to minimize PDU intrusion into equipment rack space
  • 240VAC rating on a single pole further minimizes space requirements
  • 5 kAIC and 10 kAIC versions available
  • Standard (copper and brass) and low resistance (all copper) conductors available
  • Unique handle actuator for protection against accidental “turn-off” with minimal size and no handle guard required
  • Screw terminals provide secure vibration resistant connection for high reliability applications
  • Terminal orientation allows simple power conductor routing and ease of assembly

www.sensata.com Page 2 Copyright © 2020 Sensata Technologies Inc. DELAY CURVES Agency Approval - LUX Circuit Breakers 50/60Hz Long Delay (Motor Start) 50/60Hz 125% Instant Trip 50/60Hz Medium Delay50/60Hz Short Delay 10000 1000 100 .01 .001 0 100 150 200 300 400 500 600 700 800 900 1000 125 TIME IN SECONDS DELAY 69 MAY TRIP

www.sensata.com Page 3 Copyright © 2020 Sensata Technologies Inc. CONFIGURATIONS

www.sensata.com Page 4 Copyright © 2020 Sensata Technologies Inc. DECISION TABLES See following charts. See following charts. See following charts. See following charts. See following charts. See following charts. See following charts. Poles Construction Type Frequency & Delay Amps Miscellaneous Marked (Combination On-Off / I-O) LUXH A66 1 NR61 0120.0 Example : LUXH A66-1-61-20.0-NR-01 Two Pole (One Handle per Pole), Two Pole, -1 Series, 50/60 Short Delay, 20 amps, “All Copper” Option/10kAIC, Black with White Markings Type Construction Amps Frequency & Delay Miscellaneous Marked (Combination On-Off / I-O) Poles LUX Single Pole U.L. listed per 489, C22.2 No. 5LUXH Two Pole One Handle per pole IAX Single Pole Special customer variation not covered by agency approvals. IAXH Two Pole One handle per pole 1. Individual units riveted together as a single unit are indicated by “M” following the “type” (e.g. LUXHM). Must be handles in all poles. No mechanical linkage is provided between units. 2. See ratings table for specific rating values -1 Series 8.0 8 Amp 15.0 15 Amp 16.0 16 Amp 20.0 20 Amp 25.0 25 Amp 30.0 30 Amp For other ratings, contact Sensata. -61 50/60 Short Delay -62 50/60 Long Delay -63 50/60 Extra Long / Motor Start -69 50/60 125% Instant Trip -A Metric thread mounting, terminals and screws -N “All Copper” option -R 10kAIC 1. One or more descriptors may be used as required. 2. When no sixth decision is selected, ASME/ANSI threads will be supplied. -01 Black with White Markings Screw Terminals Low Depth A6 Single Pole A66 Two Pole 1. Screw terminals are 10-32. M5 terminals are available as an option in the sixth decision.

www.sensata.comCopyright © 2020 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. CONTACT US Revised 01/14/2020 Americas 508-236-2551 electrical-protection-sales@ sensata.com Europe, Middle East & Africa +31743578156 info-sse@list.sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 AGENCY APPROVALS

  • UL-489 Listed and IEC 60947-2 (pending) WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
  • The product’s side panels may be hot, allow the product to cool before touching
  • Follow proper mounting instructions including torque values
  • Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment
  • Verify all connections and replace all covers before turning on power Failure to follow these instructions can result in death or serious injury.