Technical content
Rated for 105°C, type HZA combines the advantages of aluminum electrolytic and aluminum polymer technology. These hybrid capacitors have the ultra-low ESR characteristics of conductive aluminum polymer capacitors packaged in a V-chip, SMT case with high capacitance and voltage ratings Highlights - +105 °C, Up to 10,000 Hours Load Life - Low Leakage Current - Very Low ESR and High Ripple Current - 260 °C reflow soldering Specifications Outline Drawing CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830 Capacitance Range 10 to 330 µF Capacitance Tolerance ±20% @ 120 Hz/+20 °C Rated Voltage 25, 35, 50, 63, 80 Vdc Leakage Current (at 20°C) I = .01CV or 3 µA max., whichever is greater after 2 minutes I = leakage current in µAmps C = rated capacitance in µF V = rated DC Working voltage in Volts Low Temperature Characteristics (at 120 Hz) Z(-25 ºC)/Z(+20 ºC): 2 Z(-55 ºC)/Z(+20 ºC): 2.5 Ripple Current Frequency Multiplier Frequency 120 Hz 1000 Hz 10,000 Hz 100 KHz Correction Factor 0.1 0.3 0.6 1 RoHS Compliant Type HZA -55 ºC to +105 ºC SMT Hybrid Polymer-Aluminum Electrolytic Capacitors Case Code D (± 0.5) L ( ± 0.3) A (± 0.2) B ( ± 0.2) H (max.) I (ref.) W P (ref.) K mm Capacitor Markings Voltage Code Voltage Vdc E 25 V 35 H 50 J 63 K 80 Lot, Number: Year, Line, Month For filtering, Bypassing and Power Supply Decoupling with Long Life Requirements Film
(µF) Voltage Rating (Vdc) CDE Part Number MAX DCL (µA) MAX DF @
120 Hz/20°C
E.S.R. 100kHz/+20°C (ohms) MAX Ripple Current 100kHz/+105°C (A rms) D (mm) L (mm) Case Code QTY/reel
25 Vdc ( 32 Vdc Surge )
35 Vdc ( 44 Vdc Surge )
50 Vdc ( 63 Vdc Surge )
63 Vdc ( 79 Vdc Surge )
80 Vdc ( 100 Vdc Surge )
HZA 227 M 25 F 24T –F RoHS Compliant IndicatorPackaging Type Capacitance Capacitance Tolerance Voltage Code Case Code Code 227 = 220 µF M = ±20% 25 = 25 Vdc See Ratings Table 24 = Tape carrier width (mm) T = Tape & Reel CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830 Part Numbering System Type HZA -55 ºC to +105 ºC SMT Hybrid Polymer-Aluminum Electrolytic Capacitors Film
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830 HZA 227 M 25 F 24T –F RoHS Compliant IndicatorPackaging Type Capacitance Capacitance Tolerance Voltage Code Case Code Code 227 = 220 µF M = ±20% 25 = 25 Vdc See Ratings Table 24 = Tape carrier width (mm) T = Tape & Reel Type HZA -55 ºC to +105 ºC SMT Hybrid Polymer-Aluminum Electrolytic Capacitors Test Apply the maximum rated voltage for 10,000 hrs at +105 °C with full rated ripple current. After the test measure the capacitance, DF, DCL and ESR at +20 °C. Also measure the ESR at -40 °C and 100kHz. ∆C at 120Hz Capacitance will be within ±30% of the initial measured value DF at 120 Hz DF will be ≤ 200% of the initial specified value DCL after 2 minute charge Leakage current will be ≤ the initial specified value ESR at 100kHz/+20 °C ESR will be ≤ 200% of the initial specified value Max. ESR at 100kHz/-40 °C after Load Life test Case Code C : 2.0 Ω; Case Code D : 1.4 Ω; Case Code X : 0.8 Ω; Case Code F : 0.4 Ω; Case Code G : 0.3 Ω Load Life Test Shelf Life Test Test Subject the capacitor to 1000 hrs at +105 °C without voltage. After the test, return the capacitor to room temperature for two hours and then apply rated voltage for 30 minutes. The after test measurements for capacitance, DF, DCL and ESR at +20 °C will meet the following. ∆C at 120 Hz Capacitance will be within ±30% of the initial measured value DF at 120 Hz DF will be ≤ 200% of the initial specified value DCL after 2 minute charge Leakage current will be ≤ the initial specified value ESR at 100Khz/+20 °C ESR will be ≤ 200% of the initial specified value Moisture Resistance Test Test Subject the capacitor to 2000 hrs at +85 °C/85%RH with rated voltage. After the test, return the capacitor to room temperature and humidity for two hours. The after test measurements for capacitance, DF, DCL and ESR at +20 °C will meet the following. ∆C at 120 Hz Capacitance will be within ±30% of the initial measured value DF at 120 Hz DF will be ≤ 200% of the initial specified value DCL after 2 minute charge Leakage current will be ≤ the initial specified value ESR at 100Khz/+20 °C ESR will be ≤ 200% of the initial specified value Temperature Cycle Test Test Subject the capacitor to 1000 cycles of temperature change from -55 °C to +105 °C using the following sequence and durations. Step Temperature Time at Temperature 1 -55 ºC 30 minutes 2 +20 ºC 3 minutes max 3 +105 ºC 30 minutes 4 +20 ºC 3 minutes max After the test, return the capacitor to +20°C for one to two hours before measurement. The after test measurements for capacitance, DF, and DCL at +20 °C will meet the following; ∆C at 120 Hz Capacitance will be within ±20% of the initial measured value DF at 120 Hz DF will be ≤ 200% of the initial specified value DCL after 2 minute charge Leakage current will be ≤ the initial specified value Appearance No significant change in appearance Film
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830 Type HZA -55 ºC to +105 ºC SMT Hybrid Polymer-Aluminum Electrolytic Capacitors Reel Dimensions Case Dia. 5 6.3 8 10 W 14 18 26 26 t 3 3 3 3 mm Tape Dimensions Case Size 0.1 W1 ± 0.1 6.3 x 5.8 D 16 7 7 9.0 7.5 12 0.4 6.4 1.5 2 4 1.75 6.3 x 7.7 X 8.4 8 x 10.2 F 8.7 8.7 12.5 11.5 16 0.4 11 10 x 10.2 G 10.7 10.7 14.5 Case Size (mm) Case mm mm Film
Type HZA -55 ºC to +105 ºC SMT Hybrid Polymer-Aluminum Electrolytic Capacitors CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830 Recommended Land Dimensions Case Code D (mm) A B C C 5 1.5 2.8 1.6 D 6.3 1.8 3.2 1.6 X 6.3 1.8 3.2 1.6 F 8 3.1 4.0 2.0 G 10 4.6 4.1 2.0 Recommended Reflow Soldering Notes: 1. For 5mm and 6.3 mm case dia., if the peak temperature does not exceed 255 °C the time at or above 250 °C can increase to 10 seconds. 2. The capacitors in the 8m and 10 mm case dia. can withstand 2 reflow processes, if the peak temperature does not exceed 245 °C and the time at or abov e 240 °C does not exceed 10 seconds. 3. The 2nd reflow process should be performed after the capacitors have returned to room temperature. 4. Temperature should be measured with a thermal couple placed on the top surface of the capacitor. measured v alue when measured at room conditions. Case Code Case Dia. (mm) Peak Temperature Time at or above 250 °C Time at or above 230 °C Time at or above 217 °C Time at or above 200 °C Number of Reflow Processes C 5 260°C 5 seconds 30 seconds 40 seconds 70 seconds 2D 6.3 X 6.3 F 8 G 10 100 150 200 250 300 120 seconds 160°C Peak Temperature 200°C 70 sec. 230°C 30 sec. Temperature (ºC) Time (sec) mm Film
Type HZA -55 ºC to +105 ºC SMT Hybrid Polymer-Aluminum Electrolytic Capacitors CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830 Capacitor Temperature Characteristics 0.01 0.1 -60 -40 -20 0 20 40 60 80 100 120 120 Hz 1 kHz 10 kHz 100 kHz 0.05 0.1 0.15 0.2 -60 -40 -20 0 20 40 60 80 100 120 -40 -30 -20 -10 -60 -40 -20 0 20 40 60 80 100 120 0.01 0.1 100 -60 -10 40 90 140 -40 -30 -20 -10 0 2000 4000 6000 8000 10000 0.1 0.2 0.3 0.4 0.5 0 2000 4000 6000 8000 10000 0 2000 4000 6000 8000 10000 hours hourshours Temperature (ºC) Temperature (ºC)Temperature (ºC) Temperature (ºC) Capacitance Change (%)Capacitance Change (%) D.F.D.F. Initial Impedance (ohms) Initial E.S.R. (ohms) DCL (µA) after 2 min at rated voltage Spec. Limit: 0.28 Spec. Limit: 8.2 µA Spec. Limit: ±30% 33 µF/25V 33 µF/25V at +105 ºC with rated voltage Life Test Results 120 Hz
100 KHz
10 KHz
1 KHz
Notice and Disclaimer: All product drawings, descriptions, specifications, statements, information and data (collectively, the “Information”) in this datasheet or other publication are subject to change. The customer is responsible for checking, confirming and verifying the extent to which the Information contained in this datasheet or other publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without any guarantee, warranty, representation or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on the knowledge that the Cornell Dubilier company providing such statements (“Cornell Dubilier”) has of operating conditions that such Cornell Dubilier company regards as typical for such applications, but are not intended to constitute any guarantee, warranty or representation regarding any such matter – and Cornell Dubilier specifically and expressly disclaims any guarantee, warranty or representation concerning the suitability for a specific customer application, use, storage, transportation, or operating environment. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by Cornell Dubilier with reference to the use of any Cornell Dubilier products is given gratis (unless otherwise specified by Cornell Dubilier), and Cornell Dubilier assumes no obligation or liability for the advice given or results obtained. Although Cornell Dubilier strives to apply the most stringent quality and safety standards regarding the design and manufacturing of its products, in light of the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies or other appropriate protective measures) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product-related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicated in such warnings, cautions and notes, or that other safety measures may not be required. Film