Features

n Compatible with RoHS EU Directive 200295/EC (-Z Ver- sions) n Compatible in RoHS EU Directive 200295/EC with lead solder exemption (non -Z versions) n Delivers up to 12A output current n High efficiency: 90% at 3.3V full load (VIN = 48V) n Small size and low profile: 47.2 mm x 29.5 mm x 8.50 mm (1.86 in x 1.16 in x 0.335 in) n Low output ripple and noise n Exceptional thermal performance n High reliability: MTBF > 4.5M hours at 25 °C n Remote On/Off positive logic (primary referenced) n Constant switching frequency (285 KHz typical) n Output overvoltage and overcurrent protection n Overtemperature protection n Input undervoltage lockout n Adjustable output voltage (± 10%) n Surface mount or through-hole package n Meets the voltage and current requirements for ETSI 300-132-2 and complies with and is approved for Basic Insulation rating per IEC60950 3 rd (-B version only) n UL* 60950 Recognized, CSA† C22.2 No. 60950-00 Certi- fied, and VDE‡ 0805 (IEC60950, 3rd edition) Licensed n CE mark meets 73/23/EEC and 93/68/EEC directives§ n ISO** 9001 and ISO14001 certified manufacturing facili- ties RoHS Compliant

Description

The HW series power modules are isolated dc-dc converters that can deliver up to 12A of output current and provide a precisely regulated output voltage over a wide range of input voltages (VI = 36 V to 75 Vdc for HW modules). The modules achieve full load efficiency of 90% at 3.3 V output voltage. The open frame modules, available in both surface-mount and through-hole packaging, enable designers to develop cost- and space-efficient solutions. Standard features include remote On/Off, output voltage adjust- ment, overvoltage, overcurrent and overtemperature protection. * UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Association. ‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V. § This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipm ent should be followed. (The CE mark is placed on selected products.) ** ISO is a registered trademark of the Internation Organization of Standards

June 26, 2009 36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A HW006/010/012 Series Power Modules; dc-dc Converters Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliabiltiy. Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple stand-alone operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a time-delay fuse with a maximum rating of 5 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information. Parameter Device Symbol Min Max Unit Input Voltage:Continuous Transient (100ms) HW HW VI VI, trans –0.3 100 Vdc Vdc Operating Ambient Temperature (See Thermal Considerations section) All TA –40 85 °C Storage Temperature All Tstg –55 125 °C Parameter Device Symbol Min Typ Max Unit Operating Input Voltage HW VIN 36 48 75 Vdc Maximum Input Current (VI = 0 V to 75 V; IO = IO, max) HW II, max 1.6 Adc Inrush Transient All I2t1 A2s Input Reflected Ripple Current, peak-peak (5 Hz to 20 MHz, 12 µH source impedance See Test configuration section) All II 3 mAp-p Input Ripple Rejection (120 Hz) All 50 dB

June 26, 2009 36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A HW006/010/012 Series Power Modules; dc-dc Converters Electrical Specifications (continued) Parameter Device Symbol Min Typ Max Unit Output Voltage Set Point (VI = 48 Vdc; IO = IO, min to IO, max, TA = 25 °C) HW012A0P1 HW012A0M1 HW012A0Y1 HW010A0G1 HW010A0F1 HW006A6A1 Vo, set Vo, set Vo, set Vo, set Vo, set Vo, set 1.17 1.46 1.75 2.46 3.25 4.92 1.2 1.5 1.8 2.5 3.3 5.0 1.23 1.54 1.85 2.54 3.35 5.08 Vdc Vdc Vdc Vdc Vdc Vdc Output Voltage (Over all operating input voltage, resistive load, and temperature conditions at steady state until end of life.) HW012A0P1 HW012A0M1 HW012A0Y1 HW010A0G1 HW010A0F1 HW006A6A1 VO VO VO VO VO VO 1.15 1.44 1.73 2.42 3.2 4.85 1.25 1.56 1.87 2.57 3.4 5.15 Vdc Vdc Vdc Vdc Vdc Vdc Output Regulation: Line (VI = VI, min to VI, max) Load (IO = IO, min to IO, max) Temperature (TA = TA, min to TA, max) All All All 0.2 0.1 %, VO, set mV %, VO, set Output Ripple and Noise Measured across 10µF Tantalum, 1µF Ceramic, VI = VI, nom TA = 25 °C, IO = IO, max See test Configuration section RMS (5 Hz to 20 MHz bandwidth) Peak-to-peak (5 Hz to 20 MHz bandwidth) All All mVrms mVp-p External Load Capacitance HW006A6A1 All others CO, max CO, max 470 100 µF µF Output Current (At Io < Io,min, the output ripple may exceed the maximum specifications. All modules shall operate at no load without damage and without exceeding 110% of VO, set.) HW012A0P1 HW012A0M1 HW012A0Y1 HW010A0G1 HW010A0F1 HW006A6A1 IO IO IO IO IO IO 0.15 0.15 0.15 0.05 0.05 0.05 6.6 Adc Adc Adc Adc Adc Adc Output Current-limit Inception (VO = 90% of VO, set) HW012A0P1 HW012A0M1 HW012A0Y1 HW010A0G1 HW010A0F1 HW006A6A1 IO, lim IO, lim IO, lim IO, lim IO, lim IO, lim Adc Adc Adc Adc Adc Adc Output Short-circuit Current (Average) VO = 0.25 V HW012A0P1 HW012A0M1 HW012A0Y1 HW010A0G1 HW010A0F1 HW006A6A1 IO, s/c IO, s/c IO, s/c IO, s/c IO, s/c IO, s/c Adc Adc Adc Adc Adc Adc E fficiency (VI = VIN, nom; IO = IO, max), TA = 25 °C HW012A0P1 HW012A0M1 HW012A0Y1 HW010A0G1 HW010A0F1 HW006A6A1 h h h h h h Switching Frequency All fSW — 285 — kHz Efficiency (VI = VIN, nom; IO = IO, max), TA = 25 °C HW012A0P1 HW012A0M1 HW012A0Y1 HW010A0G1 HW010A0F1 HW006A6A1 h h h h h h

June 26, 2009 36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A HW006/010/012 Series Power Modules; dc-dc Converters Electrical Specifications (continued) Isolation Specifications General Specifications Parameter Device Symbol Min Typ Max Unit Dynamic Load Response (di/dt = 0.1 A/ µs, VI = VI, nom, TA = 25 °C) Load change from IO = 50% to 75% of IO, max, Peak Deviation Settling Time (VO < 10% of peak deviation) Load Change from IO = 50% to 25% of IO, max, Peak Deviation Setting Time (VO < 10% peak deviation) All All All All 200 0.2 200 0.2 mV msec mV msec Parameter Symbol Min Typ Max Unit Isolation Capacitance Ciso — 1000 — PF Isolation Resistance Riso 10 — — MΩ Isolation Voltage Viso — — 1500 Vdc Parameter Min Typ Max Unit Calculated MTBF (IO = 80% of IO, max TA = 25 °C) RIN (Reliability Infomation Notebook) Method 4,537,000 Hours Weight — 13 (0.46) — g (oz.)

June 26, 2009 36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A HW006/010/012 Series Power Modules; dc-dc Converters Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. Parameter Device Symbol Min Typ Max Unit Remote On/Off Signal interface (VI = VI, min to VI, max; Open collector or compatible, signal referenced to VI (-) terminal Negative Logic: Device code with suffix "1" Logic Low—Module On / Logic High—Module Off Positive Logic: If device code suffix "1" is not specified Logic Low—Module Off / Logic High—Module On Module Specifications: On/Off Current—Logic Low On/Off Voltage: Logic Low Logic High Open Collector Specifications: Leakage Current during Logic High (Von/off = 15 V) Output Low Voltage during Logic Low (Ion/Off – 1 mA) All All All All All Ion/off Von/off Von/off Ion/off Von/off –0.7 1.0 1.2 1.2 mA V V µA V Turn-On Delay and Rise Times (IO = 80% of IO, max, VIN = 48 Vdc, TA = 25 °C) Case 1: On/Off input is set to Logic high and then input power is applied (delay from instant at which VI = VI, min until VO = 10% of VO, set) Case 2: Input power is applied for at least one second and then the On/Off input is set to logic high (delay from instant at which Von/off = 0.9 V until VO = 10% of VO, set) Output voltage Rise time (time for VO to rise from 10% of VO, set to 90% of VO, set) All All All Tdelay Tdelay Trise 0.9 msec msec msec Output voltage overshoot (IO = 80% of IO, max, VI = 48 Vdc TA = 25 °C) All — — 5 %VO, set Output voltage adjustment (see Feature Description section) Output voltage set-point adjustment range (TRIM) ALL 90 — 110 %VO, set Output Overvoltage Protection (clamp) HW012A0P1 HW012A0M1 HW012A0Y1 HW010A0G1 HW010A0F1 HW006A6A1 VO, ovsd VO, ovsd VO, ovsd VO, ovsd VO, ovsd VO, ovsd 2.0 2.3 2.3 3.1 4.0 6.1 2.8 3.2 3.2 3.7 4.6 7.0 V V V V V V Overtemp eraute Protection (IO = IO, max) See Figure 44 All TQ203 — 125 — °C Input Undervoltage Lockout Turn-on Threshold Turn-off Threshold All All V V

further application guidelines. age on the remote ON/OFF pin, and off during a logic low. able leakage current of the switch at Von/off = 15 V is 50 µA. For positive logic, leave the ON/OFF pin open. For negative logic, short the ON/OFF pin to VI(–). Figure 40. Remote On/Off Implementation. feature, leave the TRIM pin open.

June 26, 2009 36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A HW006/010/012 Series Power Modules; dc-dc Converters Feature Descriptions (continued) Overtemperature Protection To provide protection under certain fault conditios, the unit is equipped with a thermal shutdown circuit. The unit will shu- down if the overtemperature threshold is exceeded, but the thermal shut down is not intended as a guarantee that the unit will survive temperatures beyond its rating. The module will automatically restart after it cools down. Input Undervoltage Lockout At input voltages below the input undervoltage lockout limit, the module operation is disabled. The module will begin to operate at an input voltage above the undervoltage lockout turn-on threshold.

June 26, 2009 36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A HW006/010/012 Series Power Modules; dc-dc Converters Outline Diagram for Surface-Mount Module Dimensions are in millimeters and (inches). 29.5 (1.16) 2.54 (0.100) min stand-off height 0.5 (.020) max compliance VO+V O- TRIM 26.16 (1.030) 5.00 (0.197) VI+V I- 35.00 (1.375) 8.50 (0.335) MAX 47.2 (1.86)Top View Side View Bottom View 0.06 x 0.06 chamffer On/Off 3.6 (0.14)1.7 (0.07) 40.00 (1.575)

June 26, 2009 36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A HW006/010/012 Series Power Modules; dc-dc Converters Outline Diagram for Through-Hole Module Dimensions are in millimeters and (inches).

June 26, 2009 36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A HW006/010/012 Series Power Modules; dc-dc Converters Recommended Pad Layout for Surface-Mount Module and Recommended Hole Layout for Through-Hole Module Component-side footprint. Dimensions are in millimeters and (inches), unless otherwise noted. 29.46 (1.160) 27.84 (1.096) 1.68 (0.066) 0 (0) 0 (0) 32.56 (1.282) 20.73 (0.816) 0 (0) 0 (0) 3.63 (0.143) 8.64 (0.340) 38.63 (1.521) 43.64 (1.718) 47.24 (1.860) NOTES: 1. FOR CGA SURFACE MOUNT PIN USE THE FOLLOWING PAD 0.022" DIA VIA 0.032" DIA SOLDER MASK OPENING

4 PLACES FOR OUTPUT PINS

2 PLACES FOR INPUT PINS

0.025" SPACING VIA TO PAD 0.015" MIN SOLDER MASK WALL 0.105" PASTE MASK OPENING 0.110" SOLDER MASK OPENING KEEP-OUT AREA: Besides trace to ON/OFF pin, do not route other traces on the PWB top layer closest to the power module in this keep-out are

Document No: ADS02-006EPS ver.1.4 PDF Name: fds03-0031.pdf Data Sheet June 26, 2009 36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A HW006/010/012 Series Power Modules; dc-dc Converters Worl d Wide Headqua rters Lineage Power Corporation

3000 Skyline Drive, Mesquite, TX 75149, USA

+1-800-526-7819 (Ou tsi de U.S.A.: +1-972-284-2626 ) www.line agepower.com e-m ail: techsupport1@linea gepower.com Asia-Pacific Headquarters Tel: +65 6416 4283 Europe, Middle-East and Afric a He adquarters Tel: +49 89 6089 286 India Headquarters Tel: +91 80 28411633 L inea ge Power reserves the right to make chang es to the produ ct(s) o r inf ormation conta ine d he rein withou t no tice. No liability is assu med a s a resu lt o f their use or app lication. No rig hts unde r any pate nt acco mpa ny the sale of a ny su ch p ro duct(s) or informatio n. © 20 08 Lineag e Power Corpo ra tion , (Mesquite, Te xas) All Intern ation al Ri ght s Re se rve d.